NOTE: Neither version is
compatible with a raised vent.
to
37”
(94.0 cm)
(88.9 cm)
35”
Backguard*
9” (22.9 cm)
45 9/16” (115.7 cm)
Document # PG05-007
All tolerances ±1/16” (±1.6 mm) unless otherwise noted.
Distinctive
All Gas Ranges
Revised 09/13/12 Page 1/4
™
30” Wide
PLANNING
GUIDE
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
Part NumberDescriptionCompatibility
AER30GLBGLowprole(13/4inch)
All specications subject to change without notice.
AERB30G033 Inch
AERB30G066 Inch
AERB30G099 Inch
OVERALL DEPTH DIMENSIONS - SIDE VIEW
AVAILABLE BACKGUARDS
Standard on models DR30GIS, DR30GIFS
Optional on models DR30GS, DR30GFS
Optional on models DR30GS, DR30GFS
NOT compatible with models DR30GIS, DR30GIFS
Standard on models DR30GS, DR30GFS
NOT compatible with models DR30GIS, DR30GIFS
Optional on models DR30GS, DR30GFS
NOT compatible with models DR30GIS, DR30GIFS
Phone: (800) 793-0093www.dacor.com
Page 2
Document # PG05-007
DR30GS, DR30GFS, DR30GIS, DR3GIFS
Revised 09/13/12 Page 2/4
Distinctive 30” Wide
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
B
13” (33.0 cm)
max.
4
14” (35.6 cm)
4
min.
Note 1
Back wall
immediately
behind range
6
A
All Gas Ranges
Top of
finished
counter
Note5
Suggested
locationof
3
utilities
PLANNING
GUIDE
■Failure to meet or exceed the maximum and
minimum dimensions/clearances stated may result
in a fire hazard.
■The range should be placed away from drafts that
may be caused by doors, windows and heating and
air conditioning outlets.
■To eliminate the risk of burns or fire by reaching
over heated surface units, cabinet storage space
located above surface units should be avoided. If
cabinet storage space is to be provided directly
above the range, the risk of personal injury may be
reduced by installing a range hood.
■In all instances, installation of a range hood is highly
recommended. The hood should project horizontally
a minimum of five (5) inches beyond the face of
the cabinets. See the range hood specifications for
minimum clearances.
■The range may be installed flush to the rear wall.
See diagram and notes for rear wall surface
requirements. It is not necessary to install noncombustible materials behind the range below the
countertop height.
■Any openings in the wall behind the appliance or in
the floor underneath it must be sealed.
Note 2
C
A*B
30” min.
(76.2 cm)
* See the cutout dimensions on following page for self-rimming installations.
30” (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24” (61 cm) min. clearance if bottom of
wood or metal cabinets are protected by not less than 1/4“ (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015”
(0.04 cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. 30” (76.2 cm) min. clearance between top of range grates and bottom
of unprotected wood or metal cabinet. If installing range hood, check the hood specifications for minimum required clearances.
2
Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See Product Dimensions.
3
Consult local code and following pages for requirements.
4
This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from edge of range.
5
10” (25.4 cm) min. to combustible sidewalls above range (both sides).
6
Non-combustible surface required for models DR30GIS and DR30GIFS up to vertical distance specified in note 1 or range hood, whichever is lower. Noncombustible surface recommended, but not required, for models DR30GS and DR30GFS.
36” (91.4 cm) recommended
30” (76.2 cm) min.
C
37” (94.0 cm)
max.
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
Page 3
Document # PG05-007
cm)�
10” min. (25.4 cm)
DR30GS, DR30GFS, DR30GIS, DR3GIFS
Revised 09/13/12 Page 3/4
Distinctive 30” Wide
SELF-RIMMING INSTALLATION CUTOUT OPTIONS (MODELS DR30GIS AND DR30GIFS ONLY)
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
10” min. (25.4 cm)
to any combustibles
above counter both sides
10” min. (25.4 cm)
to any combustibles
above counter both sides
29 1/4” (74.3 cm)
countertop opening
30” (76.2 cm)
cabinet opening
below countertop
Cabinet face
below countertop
Notch countertop
overhang to width of
CABINET DEPTH GREATER THAN 24” **
3 1/4” SIDE PANELS REMOVED, RANGE BACK
OVERHANGING COUNTERTOP (TOP VIEW)
Rear wall or
countertop edge
cabinets
*
3/4” min. (1.9 cm)
Countertop overhang
24 1/8”
(61.3 cm)
Countertop overhang
1 5/8” (4.1 cm) max.
* On models DR30GIS and DR30GIS, non-combustible surface required immediately behind range, as specified on previous page, when back of
backguard is less than 2 1/2” (6.4 cm) from rear wall.
** Models DR30GIS and DR30GIS include self-rimming trim piece that attaches to back of range and covers the edge of the countertop overhang in back.
*** To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm). This configuration is only for models
DR30GIS and DR30GIS with side panels behind door removed.
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
Page 4
Document # PG05-007
DR30GS, DR30GFS, DR30GIS, DR3GIFS
Revised 09/13/12 Page 4/4
12” (30.5 cm)
10” (25.4 cm)
Distinctive 30” Wide
All Gas Ranges
(31.1cm)
10” (25.4 cm)
(36.2cm)
12 1/4”
to
141/4”
PLANNING
GUIDE
6’ (183 cm)
long
2 1/2”
(6.4 cm)
3 1/2”
(8.9 cm)
ELECTRICAL REQUIREMENTS
Electrical Circuit
Required
120 Vac, 60 Hz, 15 Amps.,
dedicated, grounded
1” (2.5 cm)
4 1/4”
(10.8 cm)
BACK OF RANGEUTILITY CLEARANCE BEHINDRANGE
GAS SUPPLY PRESSURE REQUIREMENTS
Total Connected
Load
4.0 Amps. @
120 Vac, 60 Hz
IMPORTANT: The information above is for reference only. If the above
data does not agree with the product data label, use the data on the
product data label.
The gas inlet on the regulator accommodates a 1/2” NPT gas line
connection. The range can also accommodate a 3/4” NPT gas line
connection by removing the 1/2” to 3/4” adapter on the regulator inlet.
Gas
Type
Natural5”6”1/2 psi
LP10”11”1/2 psi
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com