Dacor DR3GIFS User Manual 2

DR30GS, DR30GFS, DR30GIS, DR3GIFS
1 1/8” (2.9 cm)
DR30GI[F]S: 1/4” (6.4 mm)
Front of open door Front of knobs
Front panel Rear of front panel
Backguard thickness
26 1/8” (66.4 cm)
28 9/16” (72.5 cm)
24” (61.0 cm)
3” (7.6 cm) backguard*
DR30G[F]S:
Full stainless
steel side panels
DR30GI[F]S:
(removable)
partial stainless
steel side panels
3 1/4” (8.3 cm)
External handle
shown, some models
(see inside cover)
have integral handle
1” above trim
Grates extend
backguard*
6” (15.2 cm)
1 3/4” (4.4 cm) backguard*
*�
See table for compatibility
Product width: 29 7/8” (75.9 cm)
NOTE: Neither version is compatible with a raised vent.
to
37”
(94.0 cm)
(88.9 cm)
35”
Backguard*
9” (22.9 cm)
45 9/16” (115.7 cm)
Document # PG05-007
All tolerances ±1/16” (±1.6 mm) unless otherwise noted.
Distinctive
All Gas Ranges
Revised 09/13/12 Page 1/4
PLANNING
GUIDE
WARNING
• Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Part Number Description Compatibility
AER30GLBG Lowprole(13/4inch)
All specications subject to change without notice.
AERB30G03 3 Inch
AERB30G06 6 Inch
AERB30G09 9 Inch
OVERALL DEPTH DIMENSIONS - SIDE VIEW
AVAILABLE BACKGUARDS
Standard on models DR30GIS, DR30GIFS Optional on models DR30GS, DR30GFS
Optional on models DR30GS, DR30GFS NOT compatible with models DR30GIS, DR30GIFS
Standard on models DR30GS, DR30GFS NOT compatible with models DR30GIS, DR30GIFS
Optional on models DR30GS, DR30GFS NOT compatible with models DR30GIS, DR30GIFS
Phone: (800) 793-0093www.dacor.com
Document # PG05-007
DR30GS, DR30GFS, DR30GIS, DR3GIFS
Revised 09/13/12 Page 2/4
Distinctive 30” Wide
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
B
13” (33.0 cm)
max.
4
14” (35.6 cm)
4
min.
Note 1
Back wall immediately behind range
6
A
All Gas Ranges
Top of finished counter
Note 5
Suggested location of
3
utilities
PLANNING
GUIDE
Failure to meet or exceed the maximum and minimum dimensions/clearances stated may result in a fire hazard.
The range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above surface units should be avoided. If cabinet storage space is to be provided directly above the range, the risk of personal injury may be reduced by installing a range hood.
In all instances, installation of a range hood is highly recommended. The hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets. See the range hood specifications for minimum clearances.
The range may be installed flush to the rear wall. See diagram and notes for rear wall surface requirements. It is not necessary to install non­combustible materials behind the range below the countertop height.
Any openings in the wall behind the appliance or in the floor underneath it must be sealed.
Note 2
C
A* B
30” min.
(76.2 cm)
* See the cutout dimensions on following page for self-rimming installations.
FREESTANDING INSTALLATION CABINET CUTOUT DIMENSIONS - MODELS DR30GS, DR30GFS, DR30GIS AND DR30GIFS
1
30” (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24” (61 cm) min. clearance if bottom of wood or metal cabinets are protected by not less than 1/4“ (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015” (0.04 cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. 30” (76.2 cm) min. clearance between top of range grates and bottom of unprotected wood or metal cabinet. If installing range hood, check the hood specifications for minimum required clearances.
2
Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See Product Dimensions.
3
Consult local code and following pages for requirements.
4
This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from edge of range.
5
10” (25.4 cm) min. to combustible sidewalls above range (both sides).
6
Non-combustible surface required for models DR30GIS and DR30GIFS up to vertical distance specified in note 1 or range hood, whichever is lower. Non­combustible surface recommended, but not required, for models DR30GS and DR30GFS.
36” (91.4 cm) recommended
30” (76.2 cm) min.
C
37” (94.0 cm)
max.
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com