Dacor DR30EIS, DR30EFS, DR30EIFS User Manual

DR30ES, DR30EFS, DR30EIS, DR30EIFS
1” (2.5 cm)
Front of open door Front of handle/knobs Front panel Rear of front panel
Backguard thickness
3” (7.6 cm) backguard*
External handle
shown, some models
have integral handle
(see inside cover)
6” (15.2 cm) backguard*
*
See table for compatibility
Product width: 29 15/16” (76.0 cm)
35”
(88.9 cm)
to
37”
(94.0 cm)
9” (22.9 cm) Backguard*
A B C D
DR30EI[F]S: 3/8” (9.5 mm)
DR30E[F]S:
Full stainless
steel side panels
DR30EI[F]S:
3” (7.6 cm)
partial stainless
steel side panels
(removable)
Document # PG05-008
Distinctive
Electric Ranges
Model Versions
Model Configuration Handle Type
DR30ES
DR30ES-C*
DR30EFS
DR30EFS-C*
DR30EIS
DR30EIFS
* -C indicates Canadian wiring configuration, see page 3/4 for details.
Freestanding,
(full size side panels)
Freestanding,
(full size side panels)
Freestanding,
(full size side panels)
Freestanding,
(full size side panels)
Built-in/Slide-in
(3 1/4” removable side panels)
Built-in/Slide-in
(3 1/4” removable side panels)
Mounted on
outside of door
Mounted on
outside of door
Flush handle,
integrated in door
Flush handle,
integrated in door
Mounted on
outside of door
Mounted on
outside of door
Revised 11/09/12 Page 1/4
PLANNING
GUIDE
WARNING
• Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Available Backguards
Part Number Description Compatibility
ADRB30E03 3 Inch Optional on all models
ADRB30E06 6 Inch
ADRB30E09 9 Inch Optional on all models
Models DR30EIS and DR30EIFS come equipped from the factory with flat stainless trim piece in place of a backguard. A backguard may be purchased as an optional accessory.
Standard on models DR30ES, DR30EFS Optional on models DR30EIS, DR30EIFS
Product Dimensions
All tolerances ±1/16” (±1.6 mm) unless otherwise noted.
All specications subject to change without notice.
OVERALL DEPTH DIMENSIONS - SIDE VIEW
Dimension DR30ES, DR30EIS DR30EFS, DR30EIFS
A 46 1/8” (117.2 cm) 46” (116.8 cm)
B 27 3/4” (70.5 cm) 27 5/8” (70.2 cm)
C 25 3/8” (64.5 cm) 25 1/4” (64.1 cm)
D 23 1/4” (64.1 cm) 23 1/8” (58.7 cm)
The trim on models DR30ES and DR30EFS are not compatible with a raised vent.
Models DR30EIS and DR30EIFS are compatible with Dacor raised vent models ERV3015. Use only theses specified raised vent models.
Phone: (800) 793-0093www.dacor.com
Document # PG05-008
DR30ES, DR30EFS, DR30EIS, DR30EIFS
Revised 11/09/12 Page 2/4
Distinctive 30” Wide
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
B
13” (33.0 cm)
4
max.
18” (45.7 cm)
min.
Note 2
4
Non-combustible surface along back wall recommended
Note 1
A
Electric Ranges
Top of finished counter
Note 5
Suggested location of
3
utilities
PLANNING
GUIDE
Failure to meet or exceed the maximum and minimum dimensions/clearances stated may result in a fire hazard.
The shaded area shown denotes the location of the electrical junction box/receptacle. This is the suggested location. For replacement purposes, the location of the existing electrical supply may be utilized provided that it does not interfere with the sides or rear of the range.
Access to the remote circuit breaker panel/fuse box, with the range in place and operating, must also be allowed for in the installation.
The electrical junction box/receptacle must be located so that it does not interfere with the range when it is installed and under operation. In addition, the junction box/receptacle must be located so the range can be removed for service and remain connected to power.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above surface units should be avoided. If cabinet storage space is to be provided directly above the range, the risk of personal injury may be reduced by installing a range hood.
In all instances, installation of a range hood is highly recommended. The hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets. See the range hood specifications for minimum clearances.
The range may be installed flush to the rear wall. See diagram and notes for rear wall surface requirements. It is not necessary to install non­combustible materials behind the range below the countertop height.
Any openings in the wall behind the appliance or in the floor underneath it must be sealed.
C
A* B
30 1/16” min.
(76.4 cm)
* See the cutout dimensions on following page for self-rimming installations.
FREESTANDING INSTALLATION CABINET CUTOUT DIMENSIONS - MODELS DR30ES, DR30EFS, DR30EIS AND DR30EIFS
1
30” (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24” (61 cm) min. clearance if bottom of wood or metal cabinets are protected by not less than 1/4“ (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015” (0.04 cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. 30” (76.2 cm) min. clearance between top of range grates and bottom of unprotected wood or metal cabinet. If installing range hood, check the hood specifications for minimum required clearances.
2
Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See Product Dimensions.
3
Consult local code and following pages for requirements.
4
This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from edge of range.
5
10” (25.4 cm) min. to combustible sidewalls above range (both sides).
All specications subject to change without notice.
36” (91.4 cm) recommended
30” (76.2 cm) min.
C
37” (94.0 cm)
max.
Phone: (800) 793-0093www.dacor.com
Document # PG05-008
Rear wall or countertop edge
countertop opening
29 1/4” (74.3 cm)
30 1/16” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (9.5 mm)
countertop overhang
10” min. (25.4 cm) to any combustibles above counter both sides
19 7/8”
(50.5 cm)
to
22 7/8”
(58.1 cm)
19 7/8”
(50.5 cm)
24 1/2”
(62.2 cm)
max.
Countertop front
Rear wall or countertop edge
countertop opening
29 1/4” (74.3 cm)
30 1/16” (76.2 cm)*
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (9.5 mm)
countertop overhang
10” min. (25.4 cm) to any combustibles above counter both sides
22 7/8”
(58.1 cm)
24 1/2”
(62.2 cm)
max.
Countertop front
DR30ES, DR30EFS, DR30EIS, DR30EIFS
Revised 11/09/12 Page 3/4
Distinctive 30” Wide
Electric Ranges
Electrical Specifications
ELECTRICAL REQUIREMENTS
Electrical Circuit
Required
240 Vac 60 Hz, 4 wire*,
50 Amp.
*Two 120 Vac hot (L1 and L2), one neutral (N1) and one ground.
**This information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label.
IMPORTANT: Models DR30ES-C and DR30EFS-C are freestanding ranges that come with a factory installed 4-wire appliance cord and NEMA 14-50P plug. This wiring configuration is required for freestanding ranges installed in Canada, although they may be used elsewhere, if local codes permit. The plug is designed to plug directly into a NEMA 14-50R electrical receptacle installed by a licensed electrician according to the above specifications.
Total Connected
Load**
11.94kW (49.75 Amp.)
PLANNING
GUIDE
Factory Wiring
Model Factory Electrical Connection
DR30ES Power cord not installed. Not for installation in Canada.
DR30ES-C
DR30EFS No power cord. Not for installation in Canada.
DR30EFS-C
DR30EIS No power cord. May be installed in Canada and U.S.A.
DR30EIFS No power cord. May be installed in Canada and U.S.A.
Cord connected, for installation in Canada and U.S.A.,
Cord connected, for installation in Canada and U.S.A.,
where local codes permit.
where local codes permit.
10” (25.4 cm)
10” (25.4 cm)
12 (30.5 cm)
NEMA 14-50P PLUG NEMA 14-50R RECEPTACLE
Self-Rimming Installation Cutout Options (Models DR30EIS and DR30EIFS Only)
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
Countertop height: 34 3/4” (88.3 cm) min. 36 7/8” (93.7 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max.
2 1/2”
(6.4 cm)
3 1/2”
(8.9 cm)
UTILITY CLEARANCE BEHIND RANGE
1” (2.5 cm)
TOP VIEW - SLIDE-IN, SELF-RIMMING INSTALLATION, 3”
All specications subject to change without notice.
* To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm), with the width at the notches remaining 30 1/16”. This configuration is only for models DR30EIS and DR30EIFS with side panels behind door removed.
SIDE PANELS INSTALLED
TOP VIEW - SLIDE-IN, SELF-RIMMING INSTALLATION, 3”
SIDE PANELS REMOVED
Phone: (800) 793-0093www.dacor.com
Document # PG05-008
DR30ES, DR30EFS, DR30EIS, DR30EIFS
Revised 11/09/12 Page 4/4
Distinctive 30” Wide
Electric Ranges
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
Only models DR30EIS and DR30EIFS may be installed with a raised vent. Use only Dacor raised vent model ERV3015.
A self-rimming countertop configuration is required for raised vent installation. On installations with a raised vent, when sliding the range into position, it will stop when the rear of the control panel or side panels contact the notches toward the front of the countertop.
The self-rimming installation of the DR30DI range and ERV3015 raised vent create a “built-in” look where the range trim overlaps the countertop on both sides and the raised vent overlaps the countertop in back.
10” min. (25.4 cm) to any combustibles above counter both sides
24 3/8”
(61.9 cm)
max.
Countertop front
raised vent opening
countertop opening
to width of cabinets
Rear wall or countertop edge
27 1/2” (69.9 cm)
29 1/4” (74.3 cm)
30 1/16” (76.2 cm)
cabinet opening
below countertop
Notch countertop
Cabinet face
below countertop
3/8” min. (1.0 cm)
countertop overhang
2 5/8” (6.7 cm)
19 3/4”
19 3/4”
(50.2 cm)
(50.2 cm)
22 3/4
(57.8 cm)
Countertop height: 34 3/4” (88.3 cm) min. 36 7/8” (93.7 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max.
3/8” min. (1.0 cm) flat countertop overhang
3/8” min. (1.0 cm) space
to
ERV3015 raised vent
required behind ERV3015 chassis to clear stiffener
PLANNING
GUIDE
25 9/16” (64.9 cm)
Range trim resting
on countertop
Countertop
Cabinet face
Back of side panel rests against cabinet face
3 inch side panel
DR30EI[F]S range
TOP VIEW - DOWNDRAFT ERV30[15] WITH SLIDE-IN, SELF-RIMMING INSTALLATION USING
10” min. (25.4 cm) to any combustibles above counter both sides
24 3/8”
(61.9 cm)
max.
Countertop front
TOP VIEW - DOWNDRAFT ERV30[15] WITH SLIDE-IN, SELF-RIMMING INSTALLATION USING
Rear wall or countertop edge
27 1/2” (69.9 cm)
raised vent opening
29 1/4” (74.3 cm)
countertop opening
30 1/16” (76.2 cm)*
cabinet opening
below countertop
Notch countertop
to width of cabinets
Cabinet face
below countertop
3” SIDE PANELS INSTALLED
3/8” min. (1.0 cm)
countertop overhang
2 5/8” (6.7 cm)
22 3/4”
(57.8 cm)
3” SIDE PANELS REMOVED
3/8” min. (1.0 cm) flat countertop overhang
ERV3015 raised vent
25 9/16” (64.9 cm)
Range trim resting
on countertop
Countertop
Cabinet face
3/8” min. (1.0 cm) space required behind ERV3015 chassis to clear stiffener
DR30EI[F]S range
* To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm), with the width at the notches remaining 30 1/16”. This configuration is only for models DR30EIS and DR30EIFS with side panels behind door removed.
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
Loading...