Dacor DR30EIS, DR30EFS, DR30EIFS User Manual

DR30ES, DR30EFS, DR30EIS, DR30EIFS
1” (2.5 cm)
Front of open door Front of handle/knobs Front panel Rear of front panel
Backguard thickness
3” (7.6 cm) backguard*
External handle
shown, some models
have integral handle
(see inside cover)
6” (15.2 cm) backguard*
*
See table for compatibility
Product width: 29 15/16” (76.0 cm)
35”
(88.9 cm)
to
37”
(94.0 cm)
9” (22.9 cm) Backguard*
A B C D
DR30EI[F]S: 3/8” (9.5 mm)
DR30E[F]S:
Full stainless
steel side panels
DR30EI[F]S:
3” (7.6 cm)
partial stainless
steel side panels
(removable)
Document # PG05-008
Distinctive
Electric Ranges
Model Versions
Model Configuration Handle Type
DR30ES
DR30ES-C*
DR30EFS
DR30EFS-C*
DR30EIS
DR30EIFS
* -C indicates Canadian wiring configuration, see page 3/4 for details.
Freestanding,
(full size side panels)
Freestanding,
(full size side panels)
Freestanding,
(full size side panels)
Freestanding,
(full size side panels)
Built-in/Slide-in
(3 1/4” removable side panels)
Built-in/Slide-in
(3 1/4” removable side panels)
Mounted on
outside of door
Mounted on
outside of door
Flush handle,
integrated in door
Flush handle,
integrated in door
Mounted on
outside of door
Mounted on
outside of door
Revised 11/09/12 Page 1/4
PLANNING
GUIDE
WARNING
• Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Available Backguards
Part Number Description Compatibility
ADRB30E03 3 Inch Optional on all models
ADRB30E06 6 Inch
ADRB30E09 9 Inch Optional on all models
Models DR30EIS and DR30EIFS come equipped from the factory with flat stainless trim piece in place of a backguard. A backguard may be purchased as an optional accessory.
Standard on models DR30ES, DR30EFS Optional on models DR30EIS, DR30EIFS
Product Dimensions
All tolerances ±1/16” (±1.6 mm) unless otherwise noted.
All specications subject to change without notice.
OVERALL DEPTH DIMENSIONS - SIDE VIEW
Dimension DR30ES, DR30EIS DR30EFS, DR30EIFS
A 46 1/8” (117.2 cm) 46” (116.8 cm)
B 27 3/4” (70.5 cm) 27 5/8” (70.2 cm)
C 25 3/8” (64.5 cm) 25 1/4” (64.1 cm)
D 23 1/4” (64.1 cm) 23 1/8” (58.7 cm)
The trim on models DR30ES and DR30EFS are not compatible with a raised vent.
Models DR30EIS and DR30EIFS are compatible with Dacor raised vent models ERV3015. Use only theses specified raised vent models.
Phone: (800) 793-0093www.dacor.com
Document # PG05-008
DR30ES, DR30EFS, DR30EIS, DR30EIFS
Revised 11/09/12 Page 2/4
Distinctive 30” Wide
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
B
13” (33.0 cm)
4
max.
18” (45.7 cm)
min.
Note 2
4
Non-combustible surface along back wall recommended
Note 1
A
Electric Ranges
Top of finished counter
Note 5
Suggested location of
3
utilities
PLANNING
GUIDE
Failure to meet or exceed the maximum and minimum dimensions/clearances stated may result in a fire hazard.
The shaded area shown denotes the location of the electrical junction box/receptacle. This is the suggested location. For replacement purposes, the location of the existing electrical supply may be utilized provided that it does not interfere with the sides or rear of the range.
Access to the remote circuit breaker panel/fuse box, with the range in place and operating, must also be allowed for in the installation.
The electrical junction box/receptacle must be located so that it does not interfere with the range when it is installed and under operation. In addition, the junction box/receptacle must be located so the range can be removed for service and remain connected to power.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above surface units should be avoided. If cabinet storage space is to be provided directly above the range, the risk of personal injury may be reduced by installing a range hood.
In all instances, installation of a range hood is highly recommended. The hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets. See the range hood specifications for minimum clearances.
The range may be installed flush to the rear wall. See diagram and notes for rear wall surface requirements. It is not necessary to install non­combustible materials behind the range below the countertop height.
Any openings in the wall behind the appliance or in the floor underneath it must be sealed.
C
A* B
30 1/16” min.
(76.4 cm)
* See the cutout dimensions on following page for self-rimming installations.
FREESTANDING INSTALLATION CABINET CUTOUT DIMENSIONS - MODELS DR30ES, DR30EFS, DR30EIS AND DR30EIFS
1
30” (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24” (61 cm) min. clearance if bottom of wood or metal cabinets are protected by not less than 1/4“ (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015” (0.04 cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. 30” (76.2 cm) min. clearance between top of range grates and bottom of unprotected wood or metal cabinet. If installing range hood, check the hood specifications for minimum required clearances.
2
Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See Product Dimensions.
3
Consult local code and following pages for requirements.
4
This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from edge of range.
5
10” (25.4 cm) min. to combustible sidewalls above range (both sides).
All specications subject to change without notice.
36” (91.4 cm) recommended
30” (76.2 cm) min.
C
37” (94.0 cm)
max.
Phone: (800) 793-0093www.dacor.com