17" (43.2 cm)
CABP3
Revised 12/06/11 Page 1/1
Renaissance® Cabinet Blower
Total Connected
Load
4 Amps. @
120Vac, 60 Hz
* At zero inches static pressure
NOTE: The CABP3 cabinet blower is approved only for use with Dacor RV series raised vents.
19 3/8"
(49.2 cm)
18 7/8"
(47.9 cm)
Blower Rating*
(CFM)
600 Nominal
585.6 Actual
Approximate
Shipping Weight
34 lbs.
PLANNING
GUIDE
WARNING
• Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the RV series Raised Vent Installation Instructions.
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated
2" (5.1 cm)
1/2" (1.3 cm)
ELECTRICAL LOCATION SIDE VIEW
Ø 7/8" (2.2 cm) (Grommet Hole)
5 3/4"
(14.6 cm)
3 3/4"
(9.5 cm)
3/8” (9 mm)
mounting flange
around perimeter
17 7/8" (45.4 cm)
18 3/8" (46.7 cm)
18 7/8" (47.9 cm)
TOP VIEW
Electrical Wiring
Access Hole
17"
(43.2 cm)
9 3/4"
(24.8 cm)
3"
(7.6 cm)
DUCT LOCATION SIDE VIEW
ISOMETRIC VIEW
All specications subject to change without notice.