Dacor AEHK2CP, CABP3, IHL48, REMP3, ILHSF8 User Manual

Ventilation Solutions
1
Ventilation Facts
POLLUTANTS TO REMOVE FROM THE KITCHEN
FACTORS THAT NEGATIVELY INFLUENCE
VENTILATION
GENERAL RULE OF THUMB
Two Types of Ventilation
Hoods
1
OVERHEAD
Powerpacks
Over-the-Range
Microwaves (OTR)
Heat, Odors, Grease,
Gases, Steam & Smoke
Open Windows & Doors, Air Conditioning Vents,
Ceiling Fans, Island Cooking, Foot Traffic
100 CFM for every 10,000 BTU
(*Increase if duct run is long or complicated)
Power Sources Factors to Consider
Width & Depth of Cooking Product
Internal Blowers
External Blowers:
REMP3, REMP16
ILHSF8, ILHSF10
(Over-the-Range models
internal blower only)
Mounting Height (see chart)
Blower Size
Duct Diameter:
Use Manufacturer’s
Recommendation
Duct Length (see chart)
2
DOWNDRAFT
Ventilation Solutions
RV
ERV
ERV-ER
PRV
Internal Blowers:
CABP3 (RV only)
External Blowers:
REMP3, REMP16
In-Line Blowers:
ILHSF8, ILHSF10
Width & Depth of Cooking Product
Blower Size
Duct Diameter:
Use Manufacturer’s
Recommendation
Duct Length (see chart)
HVAC Experts recommend
2
Ventilation Facts
Hoods: EH/EHR/MH - Bottom of the hood should be 25” minimum above
the cooktop surface. DHI, DHW, PHW - Bottom of the hood should be 30” minimum above the cooktop surface.
PowerPacks (with SS Liner): Bottom of liner should be 36" from the finished counter.
RECOMMENDED
MOUNTING HEIGHTS
RECOMMENDED DUCT LENGTHS
(VARIES BY PRODUCT)
OTR (above electric cooking): Top of microwave should be 34" above
the finished counter.
OTR (above gas cooking): Top of microwave should be 36" above the finished counter. (36" mandatory above ERD30, ER30D, ER30DSR and EGR30)
In hoods or Powerpacks, if you must install the hood higher than the recommended
*
eight, it is very important that you increase the size (width) of the hood and the power
h
Elbows & Transitions count extra-you must add to straight run
90º, 8" Round=7' 45º, 8" Round=3' 90º, Rectangle=15'
90º, 10" Round=5' 45º, 10" Round=2' 90º, Flat Rectangle Elbow=20'
Straight Transition, 8" or 10" Rd to 3
Elbow Transition, 8" or 10" Rd to 3
CFM) to provide the best possible ventilation.
(
to get the total duct run.
1/4
"x10" Rectangle = 4'
1/4
"x10" Rectangle = 25'
8" Round: 60' max
10" Round: 50' max
1/4
"x10" Rectangle: 50' max
3
DO’S & DONT’S
Ventilation Solutions
Keep duct run as short as possible.
Whenever possible, use round duct instead of rectangle.
Do not use back to back elbows–24" minimum between elbows.
Do not use flex duct.
Do not use duct smaller then the recommended size– and never reduce!
Seal ductwork with duct tape and use screws to support weight.
Match roof or wall cap with duct size.
In Pro, Island cooking, we recommend you oversize the hood a minimum of 6".
Support and insulate duct to reduce all noise and vibration.
3
Pro-Style Hoods
18" Epicure Hoods 1
8" High, 26
EH5418, EH4818, EH4218, EH3618, EH3018, EHR5418, EHR4818, EHR4218, EHR3618,
7
Deep
/8"
WIDTHS
FINISHES
INTERNAL POWERED–EH MODELS
EXTERNAL POWERED–EHR MODELS (REMOTE BLOWER OPTION) - only
one blower allowed per installation)
VENTING
CONTROLS
DUCT COVERS
EHR3018
54", 48”, 42”, 36” and 30”
Stainless Steel in standard Chrome trim. Three trim finish options are available in Black Chrome, Brass or Copper.
600 CFM (582 CFM at 0.0” static pressure) - EH4218, EH3618 & EH3018 1200 CFM (1164 at 0.0” static pressure) - EH5418, EH4818
EHR3018 or EHR3618- Use REMP3 or REMP16; ILHSF8 or ILHSF10 EHR4218, EHR4818 or EHR5418 – Use REMP16 or ILHSF10
Vents out the top (vertically) or back (horizontally) 42”, 36” & 30” hoods – 8” round single outlet 54” & 48” hoods – 8” round dual outlets, may use AHT10 to transition into a single 10” round exhaust
Hood switch will control integrated or remote blowers at 4 speed settings
Available in all standard widths – 6," 12" or 18" heights
12" Epicure Hoods 12" High, 26
7
/8" Deep
WIDTHS
FINISHES
INTERNAL POWERED–EH MODELS
EXTERNAL POWERED–EHR MODELS (REMOTE BLOWERS OPTION-
only one blower allowed per installation)
VENTING
CONTROLS
DUCT COVERS
EHR4812, EHR4212, EHR3612, EHR3012
48”, 42”, 36” and 30”
Stainless Steel in standard Chrome trim. Three trim finish options are available in Black Chrome, Brass or Copper.
600 CFM (582 CFM at 0.0” static pressure) - EH4212 or EH3612 or EH3012
1200 CFM (1164 at 0.0” static pressure) - EH4812
EHR4212 or EHR3612 or EHR3012 - Use REMP3; ILHSF8 EHR4812 - Use REMP16; ILHSF10
Vents out the top (vertically) or back (horizontally) 30", 36" or 42" hoods – 8" round single outlet 48” hoods – 8” round dual outlets, may use AHT10 to transition into a single 10” round exhaust
Hood switch will control integrated or remote blowers at 4 speed settings
Available in all standard widths – 6," 12" or 18" heights
EH4812, EH4212, EH3612, EH3012
Ventilation Solutions
4
Millennia Hoods
18" Millennia Hoods 18" High, 25
1
/2" Deep
WIDTHS
FINISH
INTERNAL POWERED–MH MODELS
VENTING
CONTROLS
DUCT COVERS
MH4818, MH3618, MH3018
48", 36” and 30”
Stainless Steel
600 CFM (582 CFM at 0.0” static pressure) - MH3618 or MH3018 1200 CFM (1164 at 0.0” static pressure) - MH4818
Vents out the top (vertically) or back (horizontally)
36” & 30” hoods- 8” round single outlet
48” – 8” round dual outlets, may use AHT10 to transition
into a single 10” round exhaust
Hood switch will control integrated blowers at 4 speed settings.
Available in all standard widths – 6," 12" or 18" heights
12" Millennia Hoods 12" High, 25
1
/2" Deep
WIDTHS
FINISH
INTERNAL POWERED–MHD MODELS
VENTING
CONTROLS
DUCT COVERS
MH4812, MH3612, MH3012
48", 36” and 30”
Stainless Steel
600 CFM (582 CFM at 0.0” static pressure) – MH3012 or MH3612 1200 CFM (1164 at 0.0” static pressure) – MH4812
Vents out the top (vertically) or back (horizontally)
36" & 30" hoods– 8" round single outlet
48" hoods - 8" round dual outlets, may use AHT10 to transition into a single 10" round exhaust
Hood switch will control integrated blowers at 4 speed settings
Available in all standard widths - 6," 12" or 18" heights
Ventilation Solutions
5
0
.30
.60
.90
1.20
1.50
1.80
2.10
2.40
65 130 195 260 325 390 455 545
Spe
e
d
4Speed 4
Spe
e
d
4
S
p
e
e
d 3Speed 3S
p
e
e
d 3
S
p
eed 2Speed 2S
p
eed 2
S
p
e
ed
1
Speed 1
S
p
e
ed
1
Static pressure - inches of water
1
0
.25
.50
.75
1.00
1.25
1.50
1.75
2.00
50 100 150 200 250 300 350 400
S
p
e
e
d
4
Speed 4
S
p
e
e
d
4
S
pee
d
3
Speed 3S
pee
d
3
Sp
e
e
d
2Speed 2
S
p
e
e
d
2
S
p
e
e
d
1
Speed 1
S
p
e
e
d
1
2
Static pressure - inches of water
0
.25
.50
.75
1.00
1.25
1.50
1.75
2.00
50 100 150 200 250 300 350 400
Speed 4Speed 4
Speed 4
Speed 3Speed 3Speed 3
Sp
e
ed 2Speed 2Sp
e
ed 2
S
p
e
e
d
1Speed 1
S
p
e
e
d
1
3
Static pressure - inches of water
0
.30
.60
.90
1.20
1.50
1.80
2.10
2.40
65 130 195 260 325 390 455 545
Sp
e
e
d
4Speed 4
Sp
e
e
d
4
S
p
e
ed 3Speed 3S
p
e
ed 3
S
p
eed
2Speed 2S
p
eed
2
S
p
e
e
d 1
Speed 1
S
p
e
e
d 1
Static pressure - inches of water
1
Blower Performance Curves
ø 146mm 4-speed
EH and MH Hoods
Centrifugal Blower
Ventilation Solutions
6
Millennia Hoods
Millennia Island Hoods - DHI602, DHI542, DHI482, DHI421, DHI361
WIDTHS 60”, 54”, 48”, 42” & 36”
FINISH Stainless Steel
INTERNAL POWERED
1200 CFM (1164 at 0.0” static pressure) - DHI602, DHI542, DHI482
600 CFM (582 CFM at 0.0” static pressure) - DHI421, DHI361
VENTING
Vents out the top (vertically), 8” round
Millennia Chimney Hoods - DHW482, DHW421, DHW361, DHW301
WIDTHS 48”, 42”, 36” & 30”
FINISH Stainless Steel
INTERNAL POWERED
1200 CFM (1164 at 0.0” static pressure) - DHW482-1200 CFM 600 CFM (582 CFM at 0.0” static pressure) - DHW421,
DHW361 & DHW301
VENTING
Vents out the top (vertically), 8” round
Millennia Chimney Hoods PHW plus choice of PHG36 or PHG30 Glass
WIDTHS 36" & 30"
FINISHES PHW is in Stainless and must order the Glass Canopy
either PHG36 or PHG30 in 6 Preference Color Options: Anthracite Gray (AG), Titanium Silver (TS), Sterling Grey (SG), Slate Green (GN), Blue Water (BU) and Black (BK) to complete the hood.
INTERNAL POWERED
600 CFM (582 CFM at 0.0” static pressure) - PHW + PHG36+ Color Choice
600 CFM (582 CFM at 0.0” static pressure) - PHW + PHG30+ Color Choice
VENTING
Vents out the top (vertically), 8” round
Ventilation Solutions
7
PowerPacks
IVS1 or IVSR1
DIMENSIONS
225⁄8" wide, 121⁄4" deep, 6" high
INTERNAL POWERED – IVS1
600 CFM (582 CFM at 0.0” static pressure)
EXTERNAL POWERED – IVSR1 (REMOTE BLOWER OPTION -
only one blower allowed per installation)
Use REMP3 – 600 CFM (572 CFM at 0.0” static pressure)
Use ILHSF8 – 600 CFM (650 CFM at 0.0” static pressure)
VENTING
Vents out the top (vertically) – 8" round
OPTIONAL STAINLESS STEEL LINERS
IHL36 for 36" Decorative Hoods
IHL30 for 30" Decorative Hoods
IVS2 or IVSR2
DIMENSIONS
341⁄2" wide, 121⁄4" deep, 6" high
INTERNAL POWERED – IVS2
1200 CFM (1164 at 0.0” static pressure)
EXTERNAL POWERED – IVSR2 (REMOTE BLOWER OPTION -
only one blower allowed per installation)
Use REMP16–1000 CFM (980 CFM at 0.0” static pressure)
Use ILHSF10–1100 CFM (1116 CFM at 0.0” static pressure)
VENTING
Vents out the top (vertically)–(2) 8" round ducts
Use Dacor ATD10 transition to (1) 10" round exhaust
OPTIONAL STAINLESS STEEL LINERS
IHL54 for 54" Decorative Hoods
IHL48 for 48" Decorative Hoods
IHL42 for 42" Decorative Hoods
Ventilation Solutions
8
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
.15
.30
.45
.60
.75
100 200 300 400 500 600
IVS1
Blower Performance Curve IVS1
Ventilation Solutions
9
Over the Range Microwaves
PMOR3021
FINISHES
Stainless Steel, Black or White
INTERNAL POWERED
300 CFM
VENTING
Vents out the top (vertically) or the back (horizontally) 31⁄4" x 10" rectangle duct
SPECIAL NOTES
Factory set for NON-VENTED MODE (Recirculating before installation)
Must turn motor 1/4 turn to change to VENTED
Only "UL" approved Over the Range Microwave/Hood to go over 30" wide gas or electric products.
Must use deflector shield (supplied) and proper mounting height.
PCOR30 Convection Model
FINISHES
Stainless Steel, Black or White
INTERNAL POWERED
300 CFM
VENTING
Vents out the top (vertically) or the back (horizontally) 31⁄4" x 10" rectangle duct
SPECIAL NOTES
Factory set for NON-VENTED MODE (Recirculating before installation)
Must turn motor 1/4 turn to change to VENTED
Only "UL" approved Over the Range Microwave/Hood to go over 30" wide gas or electric products.
Must use deflector shield (supplied) and proper mounting height.
Ventilation Solutions
0
1
Downdraft Systems
RV46, RV36, RV30
ERV30/36/48, ERV36-ER, ERV48-ER
SIZES 46," 36" & 30"
FINISHES Stainless Steel, Black or White
INTERNAL POWERED Use CABP3 blower – 600 CFM
EXTERNAL POWERED (REMOTE BLOWER OPTION - only one blower
allowed per installation)
REMP3–600 CFM, 8" round duct (572 CFM at 0.0” static pressure) REMP16–1000 CFM, 10" round duct (980 CFM at 0.0” static pressure)
ILHSF8-600 CFM (650 CFM at 0.0” static pressure), 8” round duct ILHSF10-1100 CFM (1116 CFM at 0.0” static pressure), 10” round duct
VENTING
Three options: right or left sides, or bottom
SPECIAL NOTES See pages 12, 13 and 16 for selection of products to match this downdraft system.
PRV46, PRV36, PRV30
SIZES 48" 36" & 30"
FINISHES Stainless Steel only
EXTERNAL POWERED (REMOTE BLOWER OPTION - only one blower
allowed per installation)
REMP3–600 CFM, 8" round duct (572 CFM at 0.0” static pressure) REMP16–1000 CFM, 10" round duct (980 CFM at 0.0” static pressure)
ILHSF8-600 CFM (650 CFM at 0.0” static pressure), 8” round duct ILHSF10-1100 CFM (1116 CFM at 0.0” static pressure), 10” round duct
VENTING
Transition ATD-2 included
Four optional exhaust directions: right or left sides, bottom or back
SPECIAL NOTES See pages 12, 13 and 16 for selection of products to match this downdraft system.
ERV48-ER is designed for ER48D Range only ERV36-ER is designed for ER36D Range only
SIZES 46," 36" & 30"
FINISHES Stainless Steel, Black or White
EXTERNAL POWERED (REMOTE BLOWER OPTION - only one blower
allowed per installation)
REMP3–600 CFM, 8" round duct (572 CFM at 0.0” static pressure) REMP16–1000 CFM, 10" round duct (980 CFM at 0.0” static pressure)
ILHSF8-600 CFM (650 CFM at 0.0” static pressure), 8” round duct ILHSF10-1100 CFM (1116 CFM at 0.0” static pressure), 10” round duct
VENTING
Transition ATD-2 included Four optional exhaust directions: right or left sides, bottom or back
SPECIAL NOTES See pages 12, 13 and 16 for selection of products to match this downdraft system.
Ventilation Solutions
1
1
Accessories
Remote Blower
REMP3 (shown) - 600 CFM
REMP16 - 1,000 CFM
APPLICATIONS:
Use with EHR, IVSR, RV, ERV or PRV systems
Stainless Steel Liners for PowerPacks
SIZES
Available in five widths: 54," 48," 42," 36" & 30"
IHL36 & IHL30
Use with IVS1 & IVSR1
IHL54, IHL48 & IHL42
Use with IVS2 & IVSR2
Internal Blower
CABP3 - 600 CFM
APPLICATIONS:
Install with RV model downdrafts only
Stainless Steel Duct Covers
SIZES
Available in five widths: 54," 48," 42," 36" & 30"All widths available in three heights: 6," 12" & 18
Transition Duct
Transition Duct
ATD10
Use with all IVS2 & IVSR2.
Use with EHD, EHDR4809, EHDR4209 & MHD4809.
Used to connect dual exhaust into a single 10" round exhaust.
AHT10
Use with EH5418, EHR5418, EH4818, EHR4818, EH4812, EHR4812, MH4818, & MH4812.
Used to connect dual exhaust into a single 10" round exhaust.
Remote Control Speed Switch
ARSC
Install as remote control for all blower systems except EH/EHR/MH Hoods
ARLC
To control lights except EH/EHR/MH Hoods
ARSLC
To control both blower & lights except EH/EHR/MH Hoods
Ventilation Solutions
2
Static pressure - inches of water
2.00
2.50
3.00
3.50
4.00
0
.50
1.00
1.50
Airflow CFM (Cubic feet/minute)
100 200 300 400 500 600 700
REMP3
1
Blower Performance Curve REMP3
Ventilation Solutions
3
Static pressure - inches of water
.50
1.00
1.50
2.00
2.50
0.00
Airflow CFM (Cubic feet/minute)
200 400 600 800 1000 1200
REMP16
1
Blower Performance Curve REMP16
Ventilation Solutions
4
Static pressure - inches of water
2.00
2.50
3.00
3.50
4.00
1.50
0.50
0.00
1.00
Airflow CFM (Cubic feet/minute)
100 200 300 400 500 600 700
CABP3
1
Blower Performance Curve CABP3
Ventilation Solutions
5
1
In-Line Blowers
ILHSF8
POWER
600 CFM (650 CFM at 0.0” static pressure)
VENTING
8" round duct
APPLICATIONS
In-line Blower for a remote application
MAKE-UP OR REPLACEMENT AIR SYSTEM
Have your builder contact their HVAC contractor to see if this is required in your area.
ILHSF10
POWER
1100 CFM (1116 CFM at 0.0” static pressure)
VENTING
10" round duct
APPLICATIONS
In-line Blower for a remote application
MAKE-UP OR REPLACEMENT AIR SYSTEM
Have your builder contact their HVAC contractor to see if this is required in your area.
Ventilation Solutions
6
1
Creating the Proper Ventilation System 1
Select Cooking Product
OOKING PRODUCT
C
ODEL
M
ER48D
ER36D
OOD
H
H5418 or EHR5418
E EH4818 or EHR4818 EH4812 or EHR4812
MH4818, MH4812
DHI542, DHI482,
DHW482
EH4218 or EHR4218 EH4212 or EHR4212 EH3618 or EHR3618 EH3612 or EHR3612
MH3618, MH3612
DHI421, DHI361
DHW421, DHW361
PHW+PHG36+Color
INTEGRATED VENT
SYSTEM
IVS2 or IVSR2
Plus IHL54 or IHL48
IVS2 or IVSR2 +
IHL42
IVS1 or IVSR1 +
IHL36
OVER THE RANGE
(OTC)
NA
NA
RAISED VENT
SYSTEM
ERV48-ER
(must use
remote blower)
ERV36-ER
(must use
remote blower)
ER30DSR
ER30D
ERD30
EGR30
ESG486
EG486
ESG366
EG366
SGM466
EH3618 or EHR3618 EH3612 or EHR3612 EH3018 or EHR3018 EH3012 or EHR3012 MH3618 or MH3018 MH3612 or MH3012
DHI361
DHW361, DHW301 PHW+PHG36+Color PHW+PHG30+Color
EH5418 or EHR5418 EH4818 or EHR4818 EH4812 or EHR4812
MH4818, MH4812
DHI542, DHI482, DHW482
EH4218 or EHR4218 EH4212 or EHR4212 EH3618 or EHR3618 EH3612 or EHR3612
MH3618, MH3612
DHI421, DHI361,
DHW421, DHW361
EH4818 or EHR4818 EH4812 or EHR4812
MH4818, MH4812
DHI482, DHW482
IVS1 or IVSR1 +
IHL36
IVS1 or IVSR1 +
IHL30
IVS2 or IVSR2
Plus IHL54 or IHL48
IVS2 or IVSR2 + IHL42 IVS1 or IVSR1 + IHL36
IVS2 or IVSR2
Plus IHL54 or IHL48
PCOR30 or
PMOR3021
with
ILHSF8 and
ARSC (with
deflector
shield)
NA
NA
NA
ERV30 with
ERD30, ER30DSR
(EGR30 not
approved for use
with downdraft)
(must use
remote blower)
ERV48
(must use
remote blower)
ERV36
(must use remote
blower)
RV46
(CABP3 or remote
blower)
PRV46
(must use remote
blower)
Ventilation Solutions
7
1
Creating the Proper Ventilation System 2
Selecting Cooking Product
COOKING PRODUCT MODEL HOOD
EH4218 or EHR4218 EH4212 or EHR4212
EH3618 or EHR3618
RGC365
SGM365
EH3612 or EHR3612
MH3618 or MH3612
DHI421 or DHI361
DHW421 or DHW361
PHW+PHG36+Color
EH3618 or EHR3618 EH3612 or EHR3612 EH3018 or EHR3018 EH3012 or EHR3012
RGC304
SGM304
MH3618 or MH3612 MH3018 or MH3012
DHI361
DHW361 or DHW301
PHW+PHG36+Color PHW+PHG30+Color
EH4218 or EHR4218 EH4212 or EHR4212 EH3618 or EHR3618
METB365-1
ETT365-2
EH3612 or EHR3612 MH3618 or MH3612
DHI421or DHI361
DHW421 or DHW361
PHW+PHG36+Color
NTEGRATED VENT
I
YSTEM
S
VS2 or IVSR2 +
I
IHL42
IVS1 or IVSR1 +
IHL36
IVS1 or IVSR1 +
IHL36
or IHL30
IVS2 or IVSR2 +
IHL42
IVS1 or IVSR1 +
IHL36
VER THE RANGE
O
OTR)
(
NA
PCOR30 or PMOR3021
(add ILHSF8 &
ARSC if you
want 600 CFM)
NA
AISED VENT
R
YSTEM
S
ERV36 or RV36
(with appropriate
remote blower)
PRV36
(must use remote
blower)
ERV30 or RV30
(with appropriate
blower)
PRV30
(must use remote
blower)
ERV36 or RV36
(with appropriate
blower)
PRV36
(must use remote
blower)
MET304
ETT304-1
MRES30S
Ventilation Solutions
EH3618 or EHR3618 EH3612 or EHR3612 EH3018 or EHR3018 EH3012 or EHR3012 MH3618 or MH3612 MH3018 or MH3012
DHI361
DHW361 or DHW301
PHW+PHG36+Color PHW+PHG30+Color
EH3618 or EHR3618 EH3612 or EHR3612 EH3018 or EHR3018 EH3012 or EHR3012 MH3618 or MH3612 MH3018 or MH3012
DHI361
DHW361 or DHW301
PHW+PHG36+Color PHW+PHG30+Color
IVS1 or IVSR1+ IHL36 or IHL30
IVS1 or IVSR1+ IHL36 or IHL30
PCOR30 or PMOR3021
(add ILHSF8 &
ARSC if you
want 600 CFM)
PCOR30 or PMOR3021
(add ILHSF8 &
ARSC if you want
600 CFM)
ERV30 or RV30
(with appropriate
blower)
PRV30
(must use remote
blower)
ERV30
(must use remote
blower)
PRV30
(must use remote
blower)
8
1
Creating the Proper Ventilation System 3
Build the Ventilation Package
STEP:
Select
Vent System / Model
VENT SYSTEMS
8" Pro Hood
1
nternal Blower
I
18" Pro Hood
External Blower
1
ODEL
M
EH4218
EH3618
EH3018
EH5418
EH4818
EHR4218
EHR3618
EHR3018
EHR5418
EHR4818
NTERNAL
I
OWER
P
Included 600
CFM (582 at
0.0” static pressure)
Included
1200 CFM
(1164 at
0.0” static pressure)
NA
NA
2
Select
Blower
EMOTE
R
OWER
P
NA
NA
REMP3
REMP16
ILHSF8
ILHSF10
REMP16
or
ILHSF10
3
Duct Size
Needed
(minimum)
UCT SIZE
D
(one)
8" round
(two)
8" round
AHT10 may
be used to
transition to
a single 10"
duct exhaust
(one)
8" round
(two)
8" round
AHT10 may
be used to
transition to a
single 10"
duct exhaust
4
Max Length for 1 Blower
System
AX
M
ENGTH
L
60'
50' for 10"
60' for 8"
60'
50' for 10"
60' for 8"
5
Determine
Duct Length
Incl. Elbows
& Trans.
UCT
D ENGTH
L
OMMENTS
C
Ask builder
about
make-up
air
Only one blower is
allowed
Ask builder
about
make-up air
Only one blower is
allowed.
.
12" Pro Hood
Internal Blower
12" Pro Hood
External Blower
EH4212
EH3612
EH3012
EH4812
EHR4212
EHR3612
EHR3012
EHR4812
Included 600
CFM (582 at
0.0” static pressure)
Included 1200
CFM (1164 at
0.0” static pressure)
NA
NA
NA
NA
REMP3
REMP16
ILHSF8
ILHSF10
REMP16 ILHSF10
(one)
8" round
(two)
8" round
AHT10 may be
used to
transition to a
single 10" duct
exhaust
(one)
8" round
(two)
8" round
AHT10 may be
used to
transition to a
single 10" duct
exhaust
60'
50' for 10"
60' for 8"
60'
50' for 10"
60' for 8"
Ask builder
about
make-up air
Only one blower is
allowed
Ask builder
about
make-up air.
Only one blower is
allowed.
Ventilation Solutions
9
1
Creating the Proper Ventilation System 4
Build the Ventilation Package
Select
Vent System / Model
ENT SYSTEMS
V
18" Millennia Wall
Mounted Hood
12" Millennia Wall
Mounted Hood
1
ODEL
M
MH3618 MH3018
MH4818
MH3612 MH3012
MH4812
NTERNAL
I
OWER
P
Included 600
CFM (582 at
0.0” static pressure)
Included
1200 CFM
(1164 at
0.0” static pressure)
Included 600
CFM (582 at
0.0” static pressure)
Included
1200 CFM
(1164 at
0.0” static pressure)
2
Select
Blower
EMOTE
R
OWER
P
NA
NA
NA
NA
35
Duct Size
Needed
(minimum)
UCT SIZE
D
(one)
8" round
(two)
8" round
AHT10 may
e used to
b ransition to
t
a single 10"
xhaust
e
(one)
8" round
4
Max Length for 1 Blower
System
AX
M
ENGTH
L
60'
50' for 10"
60' for 8"
60'
etermine Duct
D
Length Incl.
lbows & Trans.
E
UCT
D
ENGTH
L
OMMENTS
C
Ask builder
about
make-up
air
(two)
8" round
AHT10 may
be used to
transition to
a single 10"
exhaust
50' for 10"
60' for 8"
Ask builder
about
make-up
air
Millennia Island Hood
Millennia
Chimney Hood
Preference Hood
DHI602 DHI542 DHI482
DHI421 DHI361
DHW482
DHW421 DHW361 DHW301
PHW + PHG36
OR
PHG30
(colored glass)
Included
1200 CFM
(1164 at
0.0” static pressure)
Included 600
CFM (582 at
0.0” static pressure)
Included 1200
CFM (1164 at
0.0” static pressure)
Included 600
CFM (582 at
0.0” static pressure)
Included 600
CFM (582 at
0.0” static pressure)
NA 8" round 50'
NA 8" round 60'
NA 8" round
NA 8" round
NA 8" round 50'
Ventilation Solutions
0
2
Creating the Proper Ventilation System 5
Build the Ventilation Package
Select
Vent System / Model
VENT SYSTEMS
PowerPacks
Internal & External
Over the Range
Microwaves
1STEP:
ODEL
M
IVS1
IVS2
IVSR1
IVSR2
PMOR3021
PCOR30
NTERNAL
I
OWER
P
Included
600 CFM
(582 at
0.0” static pressure)
Included
1200 CFM
(1164 at
0.0” static pressure)
NA
NA
Included
300
CFM
2
Select Blower
REMP16
EMOTE
R
OWER
P
NA
NA
REMP3 ILHSF8
ILHSF10
NA
3
Select Liner & Transition
INER
L
IHL36 or IHL30 8" round
IHL54, IHL48
I
HL42 or IHL40
IHL36 or IHL30
IHL54, IHL48
IHL42 or IHL40
NA NA
RANSITIONDUCT SIZE
T
NA
ATD10
NA
ATD10
4
Duct Size
Needed
(minimum)
10" round
8" round
10" round
31/4" x 10" rectangle
5
Max
Length
for 1
Blower
System
AX
M
ENGTH
L
60'
50'
60'
50'
40'
6
etermine
D
uct Length Incl.
D
Elbows
Trans.
&
UCT
D ENGTH
L
OMMENTS
C
Ask builder about
make-up air
Ask builder about
make-up air
RV30
Downdraft RV
CABP3
ERV48 ERV36 ERV30
NA
ERV48-ER
Downdraft ERV
ERV36-ER
PRV46 PRV36
NA
PRV30
Downdraft PRV
Ventilation Solutions
REMP3
REMP16
ILHSF8
ILHSF10
REMP3
REMP16
ILHSF8
ILHSF10
REMP3
REMP16
ILHSF8
ILHSF10
NA NA
NA NA
NA NA
31/4" x 10" rectangle
31/4" x 10" rectangle
31/4" x 10" rectangle
40'
40'
40'
Ask builder
about make-
up air if unit
is over
1000 CFM
Ask builder
about make-
up air if unit
is over
1000 CFM
Ask builder
about make-
up air if unit
is over
1000 CFM
Ventilation Solutions
©Copyright 2009 Dacor, Inc. All rights reserved. L65348 101711
800.793.0093 www.dacor.com