DÜRR 51xx, 52xx User and service manual

INDEX
Important Information
1. Notes ...................................................... 30
1.1 CE - Labelling ................................. 30
1.2 Guidelines .......................................30
1.3 General Notes ................................. 30
1.4 General Safety Notes ..................... 30
1.6 Warnings and Symbols..................31
2. Product Information ............................ 32
2.1 Correct Usage ................................ 32
2.2 Use other than that for the
intended purpose ........................... 32
2.3 Product description ........................ 32
3. Delivery Contents ................................. 33
3.1 Special Accessories ....................... 33
3.2 Disposable material ........................ 33
4. Technical Data ...................................... 34
5. Function ................................................ 36
6. Functional Description ....................... 37
6.1 Compressor .................................... 37
6.2 Control unit with pressure switch ... 37
Installation
7. Storage and
transport requirements ....................... 38
8. Requirements for Set-up .................... 39
8.1 Environmental Requirements ......... 39
8.2 Compressed Air Connection .........40
8.3 Electrical connection ....................... 41
8.4 Pressure switch check and setting42
8.5 Motor circuit breaker adjustment ... 42
8.6 Commissioning ............................... 43
8.7 Draining off condensed water .......43
9. Repairs and Maintenance ................... 44
9.1 Draining off condensed water .......44
9.2 Safety valve .................................... 44
9.3 Filter change ................................... 44
10. Circuit Diagram ..................................... 45
Use
11. Operation............................................... 47
11.1 Turning on the compressor ............ 47
12. Maintenance .......................................... 48
12.1Pressure reducer (accessory) ...... 48
12.2Adjusting the pressure reducer ....48
12.3 Draining off condensed water ....... 48
12.4Safety valve ....................................49
12.5 Filter change ................................... 49
13. Maintenance intervals - Operator /
Technician ............................................. 50
14. Decommissioning ................................ 50
Trouble-shooting
15. Tips for Technicians ............................ 51
16. Tips for Operators ................................ 53
Disposal
17. Disposal of appliance .......................... 54
Parts list
Compressor 51../52.. ............................. 56-62
29
IMPORTANT INFORMATION
1. NOTES
1.1 CE - Labelling
CE-Symbol of conformity. This symbol of conformity guarantees that this appliance conforms to the relevant safety guidelines of the European Union.
1.2 Guidelines
This appliance conforms to the following safety guidelines:
• Machine guidelines 98/37EG, with amendments.
• Electro-magnetic Compatibility 89/336/ EWG, with amendments.
• Low-voltage guidelines 73/23/EWG, with amendments.
• Pressure vessel guidelines 87/404/EWG.
1.3 General Notes
• These Installation and Operating Instructions form an integral part of the unit. They must be kept close to the unit and in readiness whenever required. Precise observance of these instructions is a pre­condition for use of the unit for the intended purpose and for its correct operation. Die Montage- und Gebrauchsanweisung sollte gegebenenfalls an Nachfolger weiter gegeben werden.
• Safety for the operator as well as trouble­free operation of the unit are only ensured if use is made of original equipment parts. Moreover, use may only be made of those accessories that are specified in the technical documentation or that have been expressly approved and released by Dürr Dental for the intended purpose. Dürr Dental cannot guarantee for the safety or proper functioning of this unit in the case where parts or accessories are used which are not supplied by Dürr Dental.
• The guarantee does not cover damage to caused to this unit where parts or accessories are used which are not supplied by Dürr Dental.
30
• The guarantee is valid for 1 year commencing from the date of delivery. Any work performed under guarantee will neither extend nor renew the guarantee.
• Dürr Dental only regard themselves as being responsible for the equipment with regard to safety, reliability and proper functioning if assembly, resettings, changes or modifications, extensions and repairs have been carried out by Dürr Dental or an agency authorised by Dürr Dental and if the equipment is used in conformity with the Installation and Operating Instructions.
• These Installation and Operating Instructions conform to the relevant version of the equipment and the underlying safety standards valid at the time of going to press. All switches, processes, trade marks, software programs and appliances named in this document are registered names.
• Any reprinting of the technical documentation, in whole or in part, is subject to prior approval of Dürr Dental being given in writing.
1.4 General Safety Notes
This compressor has been designed and constructed by Dürr Dental so that correct usage of the appliance is virtually free of any possible injury or danger. In spite of this, we feel it is our duty to mention the following safety measures in order to prevent any possible danger to all personnel.
• When using this compressor all local and relevant regulations must be observed! In the interests of trouble-free operation the operator is responsible for observing these regulations.
• Retain the packaging for possible return of the product to the manufacturers. Ensure that the packaging is kept out of the reach of children. Only the original packaging provides adequate protection during transport of the unit. Should return of the product to the manufacturers be necessary during the guarantee period, Dürr Dental accepts no responsibility for damage occurring during transport where the original packaging was not used!
• Before every use the operator must check the functional safety and the condition of the appliance.
• The operator must be knowledgeable in the operation of the appliance.
• The product is not designed to be used in medical treatment areas where there exists the danger of explosion. Areas where explosions could occur are those where flammable anesthetic material, skin cleansers, oxygen and skin disinfectants are present. This appliance is not to be used in areas where the atmosphere could cause fire.
1.5 Electrical Safety Notes
• The compressor may only be connected to an earthed safety socket or CEE-socket, depending on model of compressor.
• Before connecting the appliance to the power supply check that the electrical current and the frequency of the device as described on the appliance are compatible with that of the power supply.
• Check the appliance and the power supply cables for possible damage before switching on. Damaged cables, plugs and sockets must be replaced before use.
• In danger situations or in cases of technical defect immediately separate from the power supply (unplug).
• In cases of repairs and/or maintenance the compressor must be disconnected from the mains supply, and the air supply hoses as well as the pressurized container must be depressurized.
1.6 Warnings and Symbols
In the Installation and Operating Instructions use is made of the following terms or symbols to denote information of special importance:
Information and/or mandatory regulations or prohibitions for the prevention of personal injury or substantial property damage.
Warning! High voltage.
Special information regarding the economical use of the equipment and other information.
CE-Labeling
Disconnect from mains supply.
Warning! Hot surface.
Warning!
Compressor starts automatically.
Check environment. The appliance should not be used in wet or damp conditions.
Recycling
Observe installation and operating instructions!
31
2. PRODUCT INFORMATION
2.1 Correct Usage
This compressor is only designed for providing compressed air for dental units or similar applications.
Mounting in medical treatment units:
During the development and production of this surgery compressor all requirements concerning medical products were taken into consideration wherever possible. Thus this appliance can be mounted in medical treatment units. Where this appliance is mounted in medical treatment units, then the requirements of guidelines 93/42 EWG must be observed on installation and operation.
2.2 Use other than that for the intended purpose
The compressed air provided by this unit is not suitable for use in breathing apparatus or similar facilities without the addition of special filters, such as those used in surgical areas.
• The compressors are designed for use in
dry, ventilated rooms with an ambient temperature of +10 to +40 °C.
• Do not set up the compressor in the rain.
The machine must not be used in wet or damp conditions. Furthermore, operation in the vicinity of gases or flammable fluids is forbidden.
• Before installing the compressor in medical
facilities it must be checked that that the available material is designed to satisfy the requirements of the purpose for which is intended. Please observe the technical data.
• Any classification and conformity evaluation
should be carried out by the manufacturer of the end product.
• Any other use or use beyond what is
specified is deemed to be not for the intended purpose. The manufacturer accepts no liability for damage resulting therefrom. All risk is borne solely by the user.
2.3 Product description
The Dürr Compressor 51../52.. provides an oil-free, dry and filtered pressurized air, for use in medical units.
32
3. DELIVERY CONTENTS
Compressor with / out Dry Air System (DAS):
Compressor accessories .......... 5410-002-50
nstallation and
operating instruction ............. 9000-610-01/01
Compressor with Dry Air System (DAS) only:
Collection tank ............................ 3413-001-00
Operating instructions DAS ...... 9000-610-34
3.1 Special Accessories
The following parts are not standard and must be ordered separately.
Pressure reducer ....................... 3410-008-00
Wooden cabinet ......................... 5110-500-00
Dry Air System,
upgrade set ................................ 1640-500-52
3.2 Disposable material
Filter set compressor .................. 0832-982-00
Filter set DAS ............................... 1610-121-00
Sterile filter DAS ........................... 1640-981-00
33
4. TECHNICAL DATA
Model 5110-01 5111-01 5120-51 5121-51
Voltage V 230/1~ 230/1~ 400/3~ 400/3~ Frequency Hz 50 50 50 50 Current consumption at 7 bar A 3,8 3,8 1,5 1,5 Motor circuit breaking set at A 4,2 4,2 1,6 1,6 Power rating kW 0,68 0,68 0,71 0,71 R.P.M. min Mains fuse rating A16161010 Fuse type IP 44 IP 44 IP 44 IP 44 Noise level dB(A) 66 66 66 66 No. cylinders 1111 Flow rate at 5 bar l/min 55 53 55 53 * Charge time min3333 Open/Shutoff pressure bar 5,5 – 7,5 5,5 – 7,5 5,5 – 7,5 5,5 – 7,5 Safety valve setting bar8888 Vessel volume l25252525 Duty cycle %ED 100 50 100 50 DAS - yes - yes Filtration, filter (0832-982-00) compr. µm 10 10 10 10 Filtration, fine filter (1610-121-00) dry air µm - 3,5 - 3,5 Filtration, sterile filter (1640-981-00) dry air µm - 0,01 - 0,01 Weight kg 39 48 39 48 Dimensions Transport and storage conditions Temperature Relative humidity Operating conditions Temperature Relative humidity
(H x L x D) cm 68 x 40 x 39 68 x 39 x 40 68 x 39 x 4068 x 40 x 48
-25 °C to +55 °C 10% to 90% (no condensation)
+10 °C to 40 °C
up
to 70%
-1
1400 1400 1400 1400
* Time taken for the compressor to reach the shut-off pressure of 7.5 bar from start-up pressure of 0 bar
34
Model 5210-01 5211-01 5220-51 5221-51
Voltage V 230/1~ 230/1~ 400/3~ 400/3~ Frequency Hz 50 50 50 50 Current consumption at 7 bar A 3,8 3,8 3,5 3,5 Motor circuit breaking set at A 4,2 4,2 3,6 3,6 Power rating kW 0,68 0,68 1,5 1,5 R.P.M. min Mains fuse rating A16161010 Fuse type IP 44 IP 44 IP 44 IP 44 Noise level dB(A) 69 69 69 69 No. cylinders 2333 Flow rate at 5 bar l/min 115 110 155 110 * Charge time min 1,5 1,5 1,5 1,5 Open/Shutoff pressure bar 5,5 – 7,5 5,5 – 7,5 5,5 – 7,5 5,5 – 7,5 Safety valve setting bar8888 Vessel volume l25252525 Duty cycle %ED 100 50 100 50 DAS -ja-ja Filtration, filter (0832-982-00) compr. µm 10 10 10 10 Filtration, fine filter (1610-121-00) dry air µm - 3,5 - 3,5 Filtration, sterile filter (1640-981-00) dry air µm - 0,01 - 0,01 Weight kg 48 56 48 56 Dimensions
(H x L x D) cm 68 x 40 x 45 68 x 40 x 48 68 x 40 x 4568 x 40 x 48
Transport and storage conditions Temperature Relative humidity
-25 °C to +55 °C 10% to 90% (no condensation)
Operating conditions Temperature Relative humidity
+10 °C to 40 °C
up
to 70%
-1
1400 1400 1400 1400
* Time taken for the compressor to reach the shut-off pressure of 7.5 bar from start-up pressure of 0 bar
35
5. FUNCTION
17 18
1
2
8
3
16
14
13
15
12
10
11
4
7
6
5
36
6. FUNCTIONAL DESCRIPTION
6.1 Compressor
Atmospheric air is drawn into the cylinder chamber via a suction filter (17). The piston (18) in the cylinder then compresses this air. The inlet/outlet valve cuts off one flow route thereby forcing the air directly into the tank (10) via the non-return valve. Where a DAS is present (2), the compressed air is led through the spiral cooling pipe (3) to the dry air system (2). In this way the air, warmed on compressing, is now cooled whereby most of the water present in the air is extracted as condensated water. Each time the compressor motor is sitched ioff this condensated water is collected in the collection tank (5). The partially dry air is then fed through the drying agent (6), the Sintermetallfilter (4) and the fine filter (1) as dry and hygienic air into the compressor chamber (10). The non-return valve (7) ensures the compressed air cannot escape. The compressor motor (11) continues to provide compressed air until the pressure switch (16) registers that the pressure correct level has been achieved. (The actual pressure can be read off the pressure gauge (15).) If the maximum relative humidity in the tank (10) is exceeded, then the Polyamidband Hygrostat (8) expands, whereby a valve is opened and dry air from the tank flows in the reverse direction towards the DAS (2). During this phase the unit is regenerating. This means that the humidity present in the DAS is carried via the dry air to the collection tank (5). This regeneration procedure repeats irself until such time as the pre-set relative humidity at the Hygrostat (8) is reached.
6.2 Control unit with pressure switch
If a user appliance (turbine etc.) draws off compressed air, the tank pressure drops. If in the tank the pre-set minmum pressure as set at the pressure switch (16) is reached, then the compressor motor is activated. When the pre-set maximum pressure is reached, the compressor motor is switched off. The control unit is fitted with a pressure gauge (15) which displays the tank pressure. A safety valve (12) prevents the maximumm pressure from being exceeded, eg in case of a defect. The control unit is also fitted with a condensed water drain tap (13) and a shut­off valve (14).
37
Loading...