CY7C187
2
Maximum Ratings
(Above which the useful life may be impaired. For use r gui delines, not tested.)
Storage Temperature ......................... .. ......–65°C to +150°C
Ambient Temperature with
Power Applied.............................................–55°C to +125°C
Supply Voltage to Ground Potential
(Pin 22 to Pi n 11 ) ........ ... .. .............................. –0.5V to +7.0V
DC V oltage Applied to Outputs
in High Z State
[2]
............................................ –0.5V to +7.0V
DC Input Voltage
[2]
.........................................–0.5V to +7. 0V
Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage .......... ............ ............ .........>2001V
(per MIL–STD–883, Method 3015)
Latch-Up Current .....................................................>200 mA
Operating Range
Range
Ambient
Temperature V
CC
Commercial 0°C to +70°C 5V ± 10%
Electrical Characteristics
Over the Operating Range
7C187-15 7C187-20 7C187-25, 35
Parameter Description Test Conditions Min. Max. Min. Max. Min. Max. Unit
V
OH
Output HIGH Voltage VCC = Min.,
I
OH
= –4.0 mA
2.4 2.4 2.4 V
V
OL
Output LOW Voltage VCC = Min.,
I
OL
=1 2.0 mA
0.4 0.4 0.4 V
V
IH
Input HIGH Voltage 2.2 V
CC
2.2 V
CC
2.2 V
CC
V
V
IL
Input LOW Voltage
[2]
–0.5 0.8 –0.5 0.8 –0.5 0.8 V
I
IX
Input Load Current GND < VI < V
CC
–5 +5 –5 +5 –5 +5
µA
I
OZ
Output Leakage
Current
GND < V
O
<
VCC,
Output Disabled
–5 +5 –5 +5 –5 +5
µA
I
OS
Output Short
Circuit Current
[3]
VCC = Max.,
V
OUT
= GND
–350 –350 –350 mA
I
CC
VCC Operating
Supply Current
VCC = Max.,
I
OUT
= 0 mA
90 80 70 mA
I
SB1
Automati c C E PowerDown Current
[4]
Max. VCC, CE ≥ V
IH
40 40 20 mA
I
SB2
Automati c C E
Po wer-Down Current
Max. VCC,
CE
≥ VCC – 0.3V,
V
IN
≥ VCC – 0.3V
or V
IN
≤ 0.3V
20 20 20 mA
Capacitance
[5]
Parameter Description Test Conditions Max. Unit
C
IN
Input Capacitance TA = 25°C, f = 1 MH z,
V
CC
= 5.0V
10 pF
C
OUT
Output Capacitance 10 pF
Notes:
2. V
IL
(min.) = –3.0V for pulse durations less than 30 ns.
3. Not more than 1 output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
4. A pull-up resistor to VCC on the CE input is required to keep the device deselected during VCC power-up, otherwise ISB will exceed values given.
5. Tested initially and after any design or process changes that may affect these parameters.