Cypress SPX-5500 Series, SPX-5501, SPX-5511 Operation Manual

SPX-5500SS
SPX-5500 Series
Operations Manual
RF 900Mhz Suprex® Reader
SPX-5511 pictured
SPX-5501/5511 ! - Weatherproof Enclosure
6.75” x 3.75” x 2.00”
Temp
Storage(-55˚C to + 150˚C) Operating(-40˚C to +80˚C)
Humidity
95% (non-condensing)
Input
Unreg Input 8 to 16 VDC* @ 300mA Max
Power
Output
+5VDC @100mA
Data I/O
Interface
Reader -Wiegand, Strobed (Clock & Data), F/2F LED - 0 - 30V
Cypress Suprex SPX-5500 Series
Overview:
The SPX-5500 series of RF Wireless solutions provide a wireless bridge from card readers with gates or door hardware to most access control manufacturerʼs panels. The SPX or Suprex products include both the remote ( Door/Gate ) unit and the central ( AC Panel ) unit.
Features:
-- Service mode for setup and configuration.
--“Quiet” protocol to conserve bandwidth and power
-- Field configurable reader formats
-- Multifunction indicator for determining operational status of the unit
-- Auxiliary I/O connections available for Door/Gate/Panel status signaling.
-- Multiplexing of RF bridge providing for additional door/gate on a single RF link. (future)
Electrical Specifications:
(Each Unit)
Supply Voltage# # 8-16VDC Current# # # 500mA
RF Specifications:
900Mhz frequency spread spectrum - no licensing required
This complies with part 15 of the FCC rules
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Cypress Computer Systems 1778 Imlay City Rd Lapeer, MI 48446
WWW.CypressWorld.com Solutions@CYPRX.com Copyright @2010
1234567
8
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
x = ON
Dip switch #4 is ON
-Disable Pullup resistors
Dip switch #4 is OFF
-Enable Pullup resistors
1234567
8
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
x = ON
Dip switch #4 is ON
-Enable Pullup resistors
Dip switch #4 is OFF
-Disable Pullup resistors
RFX - 5000 Series
1-Relay1 Input
RFX - 5000 Series
2-Relay2 Input
3-Aux Out
4-Ground
5-RLY3 N.C. 6-RLY3 Com 7-RLY3 N.O.
8-RLY4 N.C. 9-RLY4 Com
10-RLY4 N.O.
N/C N/C
3-Aux Input
4-Ground
5-RLY1 N.C. 6-RLY1 Com 7-RLY1 N.O.
8-RLY2 N.C. 9-RLY2 Com
10-RLY2 N.O.
External connections and DIP Switch Settings
SPX-5500
Central Unit
SPX-5500
Remote Unit
1-D0/CLK Output 2-D1/Data Output 3-LED In 4-Prog Res 1 5-Prog Res 2 6-+5 VDC Out 7-N/C 8-N/C
Diagnostic LED
1-Ground 2-8 to 16 VDC In
1-D0/CLK Input 2-D1/Data Input 3-LED Output 4-Relay 3 In 5-Relay 4 In 6-+5 VDC Out 7-N/C 8-N/C
Diagnostic LED
1-Ground 2-8 to 16 VDC In
Central Unit Settings
DIP Switch #1 ON
-Service Mode DIP Switch #1 OFF
-Quiet Mode
Remote Unit Settings
DIP Switch #1 ON
-Service Mode DIP Switch #1 OFF
-Quiet Mode
1234567
8
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
x = ON
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Resistors
1234567
8
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
x = ON
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Quick Reference For Typical Connections
SPX-5000 Series Central Quick Reference
R1 Input Controls Strike on Remote
D0/Clock Out
R1 IN
D1/Data Out
+8 to +16 VDC
Suprex RF Central
LED In
Ground
D0/Clock D1/Data
LED
Diagnostic LED
Typical Suprex Central Connections
SPX-5000 Remote
Access
Control
(-)
(+)
Panel
Power
Supply
Switch #4 ON Disable Pullup Resistors
Switch #4 OFF Enable Pullup Resistors
DC
Door
Strike
R1 N.C. R1 Com R1 N.O.
+8 to +16 VDC
Suprex RF Remote
D0/Clock In
D1/Data In
LED Out
Ground
LED
Diagnostic LED
Typical Suprex Remote
Connections
(-)
(+)
Card
Reader
Power
Supply
Switch #4 ON Enable Pullup Resistors
Switch #4 OFF Disable Pullup
DC
Cypress Suprex RF Series - Introduction
SPX-5000 Series:
This manual covers the operation and setup of the Cypress Suprex RF (5000 Series) units. Several configurations are available with different enclosure and antenna options.
All of the units with the 5000 series part number will have the same operational functions and electrical connections.
Features:
-- DES56 Encryption for secure communications
-- Units are factory configured as matched pairs, no field channel setting is required.
-- Service mode for setup and configuration.
--“Quiet” RF protocol to conserve bandwidth and power
-- Field configurable reader formats
-- Multifunction indicator for determining operational status of the unit
-- Auxiliary I/O connections available for Door/Gate/Panel status signaling.
Electrical Specifications:
(Each Unit)
Supply Voltage# # 8-16VDC Current# # # 500mA
Radio Specifications:
Frequency# # # 900 MHz ISM band Type ## # # Frequency Hopping Spread Spectrum Transmit Power# # 100mW Receive Sensitivity## -110 dBm Interference Rejection# 70dB
Antenna Options and typical range:
Internal - Up to 500 feet #(SPX-5501)
Dipole - up to 1 Mile (SPX-5511)
Yagi - Up to 12,000 feet. (SPX-5531)
Distances given are typical line of sight. Actual distance will vary depending upon terrain, RF environment, and height of antenna.
The units are shipped configured as a matched pair and are ready to plug in and operate.
The RF units are capable of operating with multiple pairs of units in the same environment. Units on different channels can operate in the same area with minimal interference to each other. Unit channel selection is made at the factory and no field settings are necessary. Up to 8 pairs of units can operate in the same area. A serial number sticker will be present on the unit to indicate the paired units. Units matched as a pair will have the same serial number or other identification labels.
Individual units should maintain a 24" separation distance from each other when installed in a central location.
Loading...
+ 11 hidden pages