Congratulations on your choice of CYPRES, the surely safest and most accurate AAD currently available. Like most skydivers, you probably assume you will always have time to deploy your reserve canopy yourself, and that situations requiring use of an automatic activation device always happen to others. We do hope you will never have such trouble, and that your CYPRES will never have to take action to save your life. Should CYPRES ever decide to activate your reserve, it will most likely happen at a moment which, no matter how experienced and cautious
you are, justies that you haven‘t left your safety
to chance.
Smoke Jumper CYPRES 2
User’s Guide
- english version -
Airtec GmbH & Co. KG Safety Systems
CYPRES 2 User’s Guide
- english version -
CYPRES 2
Reliability made in Germany
- Smoke Jumper CYPRES 2 User’s Guide - page 3
Contents
What a Smoke Jumper CYPRES 2 is........... 3
1. Function ...................................................... 4
1.1 How CYPRES works ................................. 4
1.2 Components ............................................... 6
1.3 Power supply .............................................. 7
2. How to handle the Smoke Jumper CYPRES 2 ..... 8
2.1 How to deal with the control unit .............. 8
2.2 How to check the operativeness ................. 9
2.3 How to handle in practical use ................. 10
3. Access to unit information ....................... 12
4. Changing the release unit(s) .................... 13
5. Water contact ............................................ 15
6. Important notes for users ........................ 15
7. Error Display ........................................... 16
8. Installation ................................................ 17
9. Technical service ....................................... 18
10. Repacking of the reserves ...................... 21
11. Regarding Air Travel ............................. 23
12. Technical Data ........................................ 24
13. Warranty ................................................. 25
14. Disclaimer ............................................... 26
15. Index ........................................................ 27
16. Packing List ............................................ 28
Trade Marks ................................................. 28
page 4 - Smoke Jumper CYPRES 2 User’s Guide -
The Smoke Jumper CYPRES 2 is an Automatic Activation Device for parachutes, which is built for the needs of Smoke Jumper activities.
It initiates the reserve deployment sequence; if the Smoke Jumper should still have a vertical speed of more than 35 meters per second (78 mph) at approximately 1200 ft AGL assuming the arming handle was pulled at 3000 ft AGL.
The Smoke Jumper CYPRES 2 does its job by severing the reserve closing loop allowing the spring loaded pilotchute in the reserve container
to push away the aps of the container and to
jump out into the slipstream and initiate the re­serve opening.
What a Smoke Jumper CYPRES 2 is
- Smoke Jumper CYPRES 2 User’s Guide - page 5
1. Function
1.1 How CYPRES works
The processing unit contains a factory-pro­grammed microprocessor that is capable of real-
time calculations of the jumper‘s altitude and rate
of descent based on barometric pressure. By monitoring this data, certain criteria are gener­ated from which conclusions are drawn. Should the conclusion be that the jumper is in a danger­ous situation (i.e. still in freefall at a low altitude) the processing unit triggers the release unit which initiates the reserve deployment sequence. The release unit (cutter) system for the reserve
container is completely independent of the rig‘s
primary system, because it does not pull the rip­cord pin out of the closing loop, but rather cuts the loop inside the reserve container to release the pilot chute. Initiating the reserve deployment sequence by cutting the loop is a method invented and patented by the founder of Airtec, Helmut Cloth, in 1987.
The CYPRES‘ activation system has these advan­tages:
• The deployment sequence of the reserve para­chute can be initiated in two different ways. One method is by the jumper pulling the re­serve release handle. The other method is used by CYPRES
it automatically cuts the closing
loop.
• Mechanical components are reduced to a sin­gle movable piston in the release unit.
• The activation system is located inside the re­serve container where it is not exposed to ex-
cessive shock or other adverse inuences.
• The system is unobtrusive and can be installed
so that it is undetectable from the outside.
page 6 - Smoke Jumper CYPRES 2 User’s Guide -
The distance which the piston moves in case of an activation is approx. 5 mm.
The release unit (cutter) is a unique design specif­ically developed for CYPRES. Features include a completely self-contained enclosure to avoid expelling anything during activation.
During an 18 month long investigation by BAM (Bundesanstalt für Materialprüfung), Berlin, 99 release units were tested. The result is that BAM and the U.S. DOT have classied the CYPRES as
being non-hazardous.
Due to its high reliability and other properties, the CYPRES release unit is currently being used in aerospace applications (satellites).
• The system is unobtrusive and can be installed
so that it is undetectable from the outside.
Release unit
(cutter) with
elastic keeper
Functional diagram:
reserve closing loop
blade
plastic guide
stainless steel body
- Smoke Jumper CYPRES 2 User’s Guide - page 7
Please do not:
- pull
- lift
- carry or
- throw CYPRES by the cables
processing unit
control unit
release unit
(cutter)
1.2 Components
CYPRES consists of a control unit, a processing unit and one release unit (cutter) for 1-pin reserve container or two release units (cutters) for 2-pin reserve container.
page 8 - Smoke Jumper CYPRES 2 User’s Guide -
1.3 Power supply
No attention is needed to the power supply of Smoke Jumper CYPRES 2.
The unit is designed to function from the date
of manufacture until the rst maintenance, from the rst maintenance to the second maintenance,
and from the second maintenance until the end of warranty time without limitations concerning the number of jumps. If a Smoke Jumper CYPRES 2 should cease to function due to a faulty power supply prior to the maintenance due date, Airtec will take care of this with the highest priority.
- Smoke Jumper CYPRES 2 User’s Guide - page 9
wait!
click
wait!
wait!
click click
self-test and
calibration
unit
switched on
click
light
appears
light
appears
light
appears
The push button on the control unit should be
pressed with the ngertip alone; please do not use a ngernail or any object. Use a short clicking ac-
tion in the middle of the button. You should fa­miliarize yourself with switching Smoke Jumper CYPRES 2 on to be able to do the functioning test. With this Smoke Jumper CYPRES 2, you can use the control unit only to check the operativeness. Nothing else.
Do the operativeness check prior to every rst
jump of a day.
2. How to handle the Smoke Jumper CYPRES 2
2.1 How to deal with the control unit
The functioning test of the Smoke Jumper CYPRES 2 is initiated by pressing the push but­ton four times with very short clicks. Start the switch-on cycle by clicking the button once. After approx. one second, the red LED-light will glow. You must acknowledge the red light immedi­ately by clicking the button again. This sequence
- a click following appearance of the red light -
will be repeated two more times. After a total of four clicks, Smoke Jumper CYPRES 2 goes into self-test mode. If you do not act promptly after seeing the LEDlight, or if you push the button to soon, Smoke Jumper CYPRES 2 will ignore the