CYP Suprex SPX-7400 Series Operation Manual

!
SPX-7400_MAN_0414
SPX-7400 shown with EXP-2000
*/5&(3"5*0/40-65*0/4
SPX-7400 Series
Suprex® Reader Extender !
- Fiber Optic Interface
Operations Manual
"
This manual covers the operation and setup of the Cypress Suprex® Fiber Optic SPX-7400 series units. "
"
Overview:"
"
The SPX-7400 series of Fiber Optic solutions provides a bridge from Card Readers with gates or door hardware to most access control manufacturers panels. The SPX or Suprex® products include both the remote ( Door/Gate ) unit and the central ( AC Panel ) unit. "
"
Features:!
"
-- Available in single mode or multi-mode"
-- Includes complete solution with remote ( reader/gate/door ) and central ( panel ) interface."
-- Service mode for setup and configuration of Expansion modules."
-- Field configurable reader formats"
-- Multifunction indicator for determining operational status of the unit"
-- Auxiliary I/O connections available for Door/Gate/Panel status signaling."
-- Multiplexing of RF bridge providing for additional door/gate on a single Fiber link. "
-- Economical expansion capabilities using Suprex® Lynk technology "
"
Fiber Optic Specifications:"
"
Module connections utilize standard "ST" style connections"
"
NOTE: Single Mode or Multi Mode must be Specified at time of order."
"
SPX-7400 Multimode:####### Loss Budget####### 13 dB#### 850 nm" 62.5/125 Fiber" Loss Budget 9 dB 850 nm" 50.0/125 Fiber" " " #"
"
SPX-7410 Single mode:######Loss Budget###### 20 dB#### 1300 nm" 9/125 Fiber
Physical
SPX-7400 # - Aluminum Enclosure"
4.45x 3.08x 2.0 ( Each Unit )
Temp
Storage(-55˚C to + 150˚C)" Operating(-40˚C to +80˚C)
Humidity
95% (non-condensing)
Power
Input
Unreg Input 8 to 16 VDC* @ 300mA Max
Output
+5VDC @100mA
Data I/O
Interface
Reader -Wiegand, Strobed (Clock & Data), F/2F" LED - 0 - 30V
Relays
Max Switching (220Vdc 30W (resistive) 1A)
(250Vac 37.5VA 1A)
Running Spec with load (30Vdc 1A (resistive), 1 x 10
125Vac .3A (resistive), 1 x 10
Electrical and Mechanical Specifications
Suprex® SPX-7400 Series Overview
Cypress Computer Systems, Inc. Lapeer, MI 48446 www.cypressintegration.com
© 2014 Cypress Computer Systems Inc.
"
Cable Recommendations!
Belden or equivalent!
" " " " " "
SPX-1300, SPX-7500 and EXP-1000/2000!
"
RS-485 connection!
"
PVC - Belden 9744 - 22 AWG 2 twisted pair, 4,000 feet max."
Plenum - Belden 82741 - 22 AWG 2 twisted pair, 4,000 feet max."
" "
" "
SPX-1300, SPX-7200, SPX-7400/10, SPX-5601, SPX-5621, SPX-5521, WMR-7211, EXP-1000/2000!
"
Wiegand, power and LED!
"
PVC - Belden 9942 or 8777 - 22 AWG 3 pair shielded, 250 feet max."
Plenum - Belden 82777 - 22 AWG 3 pair shielded, 250 feet max."
PVC - Belden 9873 - 20 AWG 3 pair shielded, 500 feet max."
Plenum - Belden 83606 or 85164 - 20 AWG 3 pair shielded, 500 feet max."
" "
Inputs/outputs!
"
PVC - Belden 8451 - 22 AWG 1 pair, 1,000 feet max."
Plenum - Belden 82761 - 22 AWG 1 pair, 1,000 feet max."
" "
Power!
"
PVC - Belden 8461 - 18 AWG 1 pair, 25 feet max."
Plenum - Belden 82740 - 18 AWG 1 pair, 25 feet max."
" "
" " "
"
"
1.70
1.90
Cypress Suprex® SPX-7400 Enclosure Dimensions
8
10
12
14
16
80
55
35
-40
Ambient Temperature
(Degrees Celsius)
Supply Voltage
Temperature/Voltage de-rating curve
The Suprex® units should be operated with a filtered 12 Volt nominal DC supply. " Any voltage between 8 and 16 volts can be utilized by following the temperature /voltage derating curve. Voltage should not exceed 16 VDC under normal operating conditions. "
Temperature Rating vs Voltage Derating Curve
4.02
3.08
0.80
0.80
3.15
4.69
ø0.20 X 4
"
" " " " " " " " " " " " " "
"
" " "
" " " " " " " " " " " " "
"
"
"
"
"
" " "
" " " " " " " " " " "
External connections and DIP Switch Settings
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
x = ON
1234567
8
Dip switch #4 is ON
-Disable Pullup resistors
Dip switch #4 is OFF
-Enable Pullup resistors
DIP Switch #1 OFF"
"
See appendix for " Expansion module Setup
Central Unit Settings
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorad0 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
F2F
x = ON
1234567
8
Dip switch #4 is ON
-Enable Pullup resistors
Dip switch #4 is OFF
-Disable Pullup resistors
DIP Switch #1 OFF"
"
See appendix for" Expansion module Setup
Remote Unit Settings
1 - 8 to 16 VDC In " 2 - Ground
Status LED
1 - exp (+)" 2 - exp (-)" 3 - +5 VDC out" 4 - Prog Res 4" 5 - Prog Res 3" 6 - LED In " 7 - D1/Data out " 8 - D0/Clk out"
1- Relay 2 N.O." 2- Relay 2 Com" 3 - Relay 2 N.C." 4 - Relay 1 N.O." 5 - Relay 1 Com" 6 - Relay 1 N.C." 7 - Ground " 8 - Aux in" 9 - Not used" 10 - Not used
1 - 8 to 16 VDC In " 2 - Ground
Status LED
1 - exp (+)" 2 - exp (-)" 3 - +5 VDC out" 4 - R4" 5 - R3" 6 - LED out" 7 - D1/Data In " 8 - D0/Clk In"
1- Relay 4 N.O." 2- Relay 4 Com" 3 - Relay 4 N.C." 4 - Relay 3 N.O." 5 - Relay 3 Com" 6 - Relay 3 N.C." 7 - Ground " 8 - Aux out" 9 - R2 in" 10 - R1 in
SPX-7400!
Remote
SPX-7400!
Central
" " " "
" " "
" " " " " "
" " " " " " " " "
" "
" " " " "
"
"
"
" "
" " " " " "
" " " " " " " " "
" "
SPX-7400 Series Remote
SPX-7400 Series Central
Quick Reference For Typical Connections
DC"
Power "
Supply"
Access! Control !
Panel!
+8 to +16 VDC" Ground
Diagnostic LED
R1 Input " Controls " Strike on" Remote
R1 IN
LED In" D1/Data Out" D0/Clock Out$
Card "
Reader
DC"
Power "
Supply"
R1 N.O."
R1 Com"
R1 N.C.
Door !
Strike !
Output
+8 to +16 VDC" Ground
Diagnostic LED
LED Out " D1/Data In" D0/Clock In
See page 10 for other strike control options
Loading...