CyberPower RMCARD303 User Manual

Page 1
LINK Indicator
QUICK INSTALLATION GUIDE
Remote Management Card
RMCARD303
I
ntelligent Remote Management Card allows a UPS
system and environment sensor to be managed,
monitored, and configured
Universal connector
RMCARD303
Universal
RX/TXLink
Ethernt connector RX/TX Indicator
Definitions for LED Indicators
Link LED color
Off
On(Yellow)
TX/RX LED color
Off
On(Green)
Flash
The Remote Management Card is not connected to the Network or the Remote Management Card power is OFF
The Remote Management Card is connected to the Network
The Remote Management Card power is OFF
The Remote Management Card power is ON
- Receiving/transmitting data packet
- Reset finished
Condition
Step 2. Configure the IP address for the CyberPower Remote Management Card.
Method 1: Using the Power Device Network Utility Tool
1. Install the Power Device Network Utility Tool from the included CD. It is located on the CD in the \tools\nework folder. Double click the “Power Device Network Utility” installation file, “Setup.msi” to begin the installation.
INSTALLATION GUIDE
Step 1. Hardware Installation
1. Turn off the UPS before removing the expansion port cover on the UPS.
2. Remove the two retaining screws of the expansion port cover, then remove the cover.
3. Install the CyberPower Remote Management Card into the expansion port.
4. Re-install and tighten the retaining screws.
5. Connect the Ethernet cable to the Ethernet connector of the CyberPower Remote Management Card.
6. To connect with the environment sensor, use the RJ45 Ethernet cable. Plug one end into the Universal connector and the other end into the sensor.
7. Turn on the UPS.
2. After installation completes, run the “Power Device Network Utility” (Under “All Programs”, select “CyberPower Power Device Network Utility”.)
3. The main dialog of the Power Device Network Utility Tool program is shown in Figure. 1. The tool will display all Remote Management Cards present on the network. The "Refresh" button is used to search the entire local network again.
Figure 1. The main window of the “Power Device Network Utility” program.
4. Select the Remote Management Card you are setting up. Click on the Tools menu and select “Device Setup” or double click the Remote Management Card you want to configure.
5. You can modify the IP Address, Subnet Mask, and Gateway address for the Device MAC Address listed in the Device Network Settings window, as shown in figure 2. The default IP Address is 192.168.20.177 and the default Subnet Mask is
255.255.255.0.
6. Modify the IP, subnet mask or gateway address. Enter the new addresses into the corresponding fields.
Figure 2. The Device Network setting window.
Page 2
7. You will need to enter a User Name and Password for the Remote Management Card in the authentication window, as shown in figure 3.
*Default user name: cyber;
Default password: cyber.
8. If IP address is successful, you will see a message that the IP set up is OK, as shown in figure 4.
Figure 3. Authentication window.
Figure 4. Setup IP Address successfully message.
Conformance Approvals
FCC Warning
This equipment has been tested and found to comply with the limits for a Class A Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Any special accessories needed for compliance must be specified in the instruction.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Method 2: Using a command prompt
1. Obtain the MAC address from the label on the Remote Management Card. Each Management Card has a unique MAC address.
2. Use the ARP command to set the IP address.
Example: To assign the IP Address 192.168.10.134 for the Remote Management
Card, which has a MAC address of 00-0C-15-0A-0A-0A you will type in the following command prompt from a PC connected to the same network as the Remote Management Card.
(1) Type in “arp-s 192.168.10.134 00-0C-15-0A-0A-0A” then press Enter.
3. Use the Ping command to assign a size of 123 bytes to the IP.
(1) Type in “ping 192.168.10.134 -l 123” then press Enter. (2) If the replies are received, your computer can communicate with the IP address.
WEB INTERFACE Login Account
There are two user account types.
- Administrator (default username : cyber ; default password : cyber)
- Viewer (default username : device ; default password : cyber)
The administrator can access full functions, including enable/disable the Viewer account, and the viewer can access the read function but can not control or change any setting.
Te Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulation. Cet appareil numerique de la class A respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada.
Trouble Shooting
Problem
Unable to configure the Remote Management Card by method 1 or method 2
Unable to ping the Management Card
Lost the user name and password
Solution
1. Check the LED status , the normal condition is when yellow and green led are both on.
If green led is off :
►Check if the Remote Management Card is
properly seated in the UPS and the UPS power is on.
If yellow led is off :
►Check if the network connection is valid.
2. Check if the operated PC is on the same physical network as Management Card is .
1. Use method 1 and method 2 to get correct IP address of the Management Card.
2. If the operated PC is on the different physical network from the Management Card, verify the setting of subnet mask and the IP address of gateway.
Please refer to the “Reset to Default Setting / Recover from a Lost Password” part in the user’s manual.