CyberPower PDU32SWHVCEE18ATNET User Manual

Page 1
Switched ATS Series
Power Distribution Units
Dual Input with Reliable and Redundant Power Capability
ATSSWD0015PV-00
CyberPower Automatic Transfer Switches equipped with dual input sources provide reliable redundant power to single­corded network devices.
Configurable threshold for input voltage and device load allows extensive application scenarios. With a front digital multifunction LCD readout for real-time power monitoring and local management, you can conveniently monitor and configure the load to avoid overloads and efficiently balance load levels.
Via the SNMP/HTTP protocol through Web, SNMP, and Telnet, the ATS are able to switch outlets off and on to reboot connected equipment remotely.
CISCO Compatible
CyberPower® works with Cisco on the latest version of EnergyWise™ Compatibility. Go to http://www.cps ww.eu/pro ducts/pdu/cisco_disclaimer.htm for complete disclaimer.
APPLICATIONS
Data Closets
NAS & Servers
DVRs/Surveillance Systems
POS Systems
Transportation & Infrastructure
Emergency Systems
SERIES FEATURES
Dual Power Input with Auto-Detect/Switch Controllable Receptacles Quick Transfer Time 8-12 ms (typical) LED Status Indicator Multifunction LCD Readout Configurable Threshold for Input Voltage & Load Event and Data Logging Auto Event Notification PowerPanel® Business Edition SNMP/HTTP Remote Management Capability
Powerpanel® Business Edition
Auto-shutdown Software
PowerPanel® Business Edition Management Software, is compatible with Windows8, 7, Vista, XP, 2000, Windows Server 2012, 2008, 2003, VMware Esxi, Citrix Xenserver, Linux and Mac.
*Software functions may vary due to firmwar e version and/or hardware constraints.
CyberPower Systems Inc. All Rights Reserved.
Multifunction LCD Readout
www.cyberpower.com
Page 2
TECHNICAL SPECIFICATION
Model
Nominal
Voltage
Maximum
Input Current
Plug Type
Cord Length
(M)
Bank
Number
Outlets
Outlet Type
Maximum
Output
Current
Circuit
Break
Dimensions (H X W X D)
mm
Switched AT S
PDU15SW10ATN ET 100-120V 15A
PDU20SWT10AT NET 100-120V 20A
PDU20SW10ATN ET 100-120V 20A
PDU20SWHVT10ATN ET 200-240V 20A
PDU15SWHVIEC12ATNE T 200-240V 15A
PDU20SWHVIEC10ATNE T 200-240V 20A
PDU20SWHVCEE10AT NET 200-240V 16A IEC 309 16A*2 3.05 1 10
PDU30SWT17AT NET 100-120V 30A
PDU30SWHVT19ATN ET 200-240V 30A
PDU32SWHVCEE18AT NET 200-240V 32A IEC 309 32A*2 3.05 2 18
#All specifications are subject to change without notice. ©2015 CyberPower Systems. All Trademarks are the property of their owners. * Some models may not be available in your region. Please contact local sales for availability.
Note 1 = Derated 12A 2 = Derated 16A 3= Derated 24A 4 = Derated 12A/UL;10A/CE 5 = Derated 24A/total ; 20A/each bank 6 = 32A/total; 20A /each bank
1
NEMA 5-15P*2 3.05 1 10 (10) NEMA 5-15R 15A1 N 44 x 433 x 236 1U
2
NEMA L5-20P*2 3.05 1 10 (10) NEMA 5-20R 20A2 N 44 x 433 x 236 1U
2
NEMA 5-20P*2 3.05 1 10 (10) NEMA 5-20R 20A2 N 44 x 433 x 236 1U
2
NEMA L6-20P*2 3.05 1 10
4
IEC 320 C14*2 3.05 1 12 (12) IEC C13 15A4 N 44 x 433 x 236 1U
2
IEC 320 C20*2 3.05 1 10
3
NEMA L5-30P*2 3.05 2 17
3
NEMA L6-30P*2 3.05 2 19
(8) IEC C13
(2) IEC C19
(8) IEC C13
(2) IEC C19
(8) IEC C13
(2) IEC C19
(16) NEMA 5-20R
(1) NEMA L5-30R
(16) IEC C13
(2) IEC C19
(1) NEMA L6-30R
(16) IEC C13
(2) IEC C19
20A2 N 44 x 433 x 236 1U
20A2 N 44 x 433 x 236 1U
16A
30A5 Y 88 x 433 x 236 2U
30A5 Y 88 x 433 x 236 2U
6
32A
N 44 x 433 x 236 1U
Y 88 x 433 x 236 2U
Rack
Size
CyberPower Systems Inc. All Rights Reserved.
www.cyberpower.com
Page 3
1U
2U
CyberPower Systems Inc. All Rights Reserved.
www.cyberpower.com
Loading...