CyberPower PDU15SWHVIEC8FNET Service Manual

User Manual
Power
Distribution
Unit
www.CPSww.com
K01-0000181-00
Table of Contents
Model List...............................................................1
Introduction............................................................1
Package Contents.................................................................
Safety Precautions..............................................................
Product Features...................................................................
Installation Guide...................................................6
Horizontal Installation ...........................................................6
Vertical Installation (1U Model Only)..........................
Electrical Installation..........................................................
Network Installation.............................................................10
Operation..............................................................11
Metered Readout..................................................................11
Remote Management...........................................................11
LED Indicators.....................................................................12
Device Reset........................................................................12
Unattended/Automatic Shutdown......................................12
Firmware Upgrade...............................................12
Troubleshooting...................................................13
Frequently Ask Questions (FAQ)........................13
Conformance Approvals.....................................13
Customer Service & Warranty............................14
Product Registration............................................................
CyberPower International......................................................
Limited Warranty ...
Appendix A-Hyper Terminal................................15
Appendix B-Power Device Network Utility........16
Overview......................................................................... ......
Installation......................................................................
Launch Program............................................................
Getting Started...............................................................
Advanced Settings.........................................................
For 1U Series...........................................................
For 2U Series............................................................2
1U 15A Series...........................................................3
Technical Specification........................................3
1U 20A Series...........................................................4
Technical Specification........................................4
2U Series..................................................................5
Technical Specification........................................5
For 1U Model.........................................................
For 2U Model............................................................7
For 1U Model.........................................................
Basic Operation.......................................................11
PDU Status Screen................................................
Current Level....................................................
Input Voltage.................................................. ..
Power..............................................................
IP Address........................................................
Outlet Control.................................................
.
..............................................................14
.
.
.......
...
.
. . .
.11
..
.
.
...11
.
.14
.
....... 16
.......
.
.......
.
....
.....
..2
..6
..9
..9
11
14
16
17 17 18
11
11 11
.
1
.
1
.
3
9
Model List
Introducon
1U Switched Series
PDU15SW8FNET
PDU15SWHVIEC8FNET
PDU20SW8FNET
PDU20SWT8FNET
PDU20SWHVIEC8FNET
1U Monitored Series
PDU15M8FNET PDU15MHVIEC8FNET PDU20M8FNET PDU20MT8FNET PDU20MHVIEC8FNET
2U Switched Series
PDU30SWT16FNET PDU30SWHVT16FNET
2U
Monitored
PDU30MT16FNET PDU30MHVT16FNET
Series
Introducon
Package Contents (For 1U Series)
Package Contents (For 2U Series)
PDU
Cable Ties / Qty. 20
Mounting Brackets x 2
PDU
Mounting Bracket: 2 short & 2 long
10 (Flat Head M4x5) Bracket Mounting Screws (Includes two spares)
Cord Retention Tray
Cable Ties / Qty. 10
6 (M3x6) Cord Retention Tray Mounting Screws (Includes two spares)
6 (M5x12) Screws / 6 Washers (Includes two spares for each)
RJ45/DB9 Serial Port Connection Cable
Power Cord 10 feet, IEC-320 C13/ IEC-320 C14 (PDU15SWHVIEC8FNET/PDU15MH VIEC8FNET Model Only)
Power Cord 10 feet, IEC-320 C19/ IEC-320 C20 (PDU20SWHVIEC8FNET/PDU20MH VIEC8FNET Model Only)
CyberPower
R
Reliability. Quality. Value.
User's Manual
User Manual Registration Card CD
Registration Card
Documentation
10 (M3x6) Cord Retention Tray Mounting Screws (Includes two spares)
6 (M5x12) Screws / 6 Washers (Includes two spares for each)
RJ45/DB9 Serial Port Connection Cable
Before using, please check to ensure the package contains all the items shown above. If there are missing parts, please contact CyberPower technical support at www.CPSww.com or call 1-952-403-9500 when you are US customers. For Europe customers, please contact CyberPower at www.eu.cyberpowersystems.com/contact.htm or call +31 (0)40-2348170.
10 (Flat Head M4x5) Bracket Mounting Screws (Includes two spares)
Cord Retention Trays x 2
CyberPower
R
Reliability. Quality. Value.
User's Manual
User Manual Registration Card CD
Registration Card
Documentation
Safety Precautions
Read the following before installing or operating the Power Distribution Units (PDU):
Use only the supplied hardware to attach the mounting brackets. The PDU must be plugged into a three-wire, grounded outlet on a circuit that is protected by a fuse or circuit breaker. For PDU15xxxxx series, please use 15A circuit protector. For PDU20xxxxx series, please use 20A circuit protector. For PDU30xxxxx series, please use 30A circuit protector. Connection to any other type of Do not use extension cords or adapters with this PDU. Never install a PDU, or associated wiring or equipment, during a lightning storm. Ensure the power cord, plug, and socket are in good condition.
To prevent the risk of fire or electric shock, this PDU should be installed in a temperature
CAUTION!!
and humidity controlled indoor area free of conductive contaminants. Do not install this PDU where excessive moisture or heat is present.
power outlet may result in a shock hazard.
Product Features (1U 15A Series)
Product Features (1U 20A Series)
Front panel description
NEMA Type
1 2 3 4 5 6 7 8
A
IEC Type
1 2 3 4 5 6 7 8
A
A. Power Cord B. AC Output Outlets C. Current Level D. Input Voltage E. Power F. Load Indicator G. Ethernet Port H. Tx/Rx Indicator
Rear panel description
Front panel description
B
J
B
J
C
E
D
YU0-0000026-00
Amps
Volts
KW
Reset
N
C G
D
E
Amps
Volts
KW
Reset
N
F
- Normal
- Warning
- Overload
PDU20SWHVIEC8FNET
M
F
- Normal
- Warning
- Overload
PDU15SWHVIEC8FNET
M
G
I
H
Tx/Rx
Link
Select
Serial Port
L
K
I
H
Tx/Rx
Link
Select
Serial Port
L
K
I. Link Indicator J. Outlet Indicator (switched series only) K. Serial Port (RJ45 modular port) L. Select Button M. PDU Status Screen N. Reset Button
NEMA Type
1 2 3 4 5 6 7 8
A
IEC Type
1 2 3 4 5 6 7 8
A
Power Cord
A. B. AC Output Outlets C. Current Level D. Input Voltage E. Power F. Load Indicator G. Ethernet Port H. Tx/Rx Indicator
B
J
B
J
I.
Link Indicator
C
E
D
Amps
Volts
KW
Reset
N
C G
D
E
Amps
Volts
KW
Reset
N
F
- Normal
- Warning
- Overload
PDU20SWT8FNET
M
F
- Normal
- Warning
- Overload
PDU20SWHVIEC8FNET
M
G
I
H
Tx/Rx
Link
Select
Serial Port
L
K
I
H
Tx/Rx
Link
Select
Serial Port
L
K
J. Outlet Indicator (switched series only) K. Serial Port (RJ45 modular port) L. Select Button M. PDU Status Screen N. Reset Button
Rear panel description
A
A
A. External Site Ground
Technical Specificaon
Switched Series (1U 15A) Monitored Series (1U 15A)
Model Name PDU15SW8FNET Input
Nominal Voltage 100-120V 200-240V 100-120V 200-240V Frequency
Derated Input Current
Plug Type NEMA 5-15P IEC-320 C14 NEMA 5-15P IEC-320 C14 Power Cord Type SR (14 AWG) Socket SR (14 AWG) Socket
Power Cord Length
Output
Nominal Voltage 100-120V 200-240V 100-120V 200-240V
Derated Output Current
Outlet Type NEMA 5-15R IEC-320 C13 NEMA 5 Outlet Number
Networking Protocol Support Connectivity Physical
Dimension (H x W x D)
Environmental
Humidity Altitude Temperature
Safety Approvals
Certifications
Warranty
Product Warranty
12A 12A(UL)/10A(CE) 12A 12A(UL)/10A(CE)
12 ft/3.65 m 10 ft/3.05 m 12 ft/3.65 m 10 ft/3.05 m
12A 12A(UL)/10A(CE) 12A 12A(UL)/10A(CE)
UL 60950,
FCC Class A
PDU15SWHVIEC8FNET
TCP/IP, UDP, DHCP, SNMP, HTTP
PDU15M8FNET PDU15MHVIEC8FNET
z
50/60H
8
-15R IEC-320 C13
RJ45
1.73" x 17.05" x 4.41"/44mm x 433mm x 112mm
0 to 95% Non-condensing
14700 ft/4500 m
32 to 104/0 to 40
UL 60950, CE,
FCC Class A
UL 60950,
FCC Class A
3 years repair or replace
UL 60950, CE,
FCC Class A
A
A
A. External Site Ground
Technical Specificaon
Switched Series (1U 20A) Monitored Series (1U 20A)
UL 60950,
TENF8M02UDPTENF8WS02UDP
PDU20MHVIEC8FNET
TENF8TM02UDPTENF8TWS02UDP
P02-5 AMENP02-5 AMEN
P02-5L AMENP02-5L AMEN
UL 60950, CE,
FCC Class A
Model Name
Input
Nominal Voltage 100-120V 200-240V 100-120V 200-240V Frequency
Derated Input Current
PDU20SWHVIEC8FNET
50/60Hz
16A
Plug Type
Power Cord Type SR (12AWG) Socket SR (12 AWG) Socket
Power Cord Length
Output
Nominal Voltage 100-120V 200-240V 100-120V 200-240V
Derated Output Current
Outlet Type NEMA 5-20R IEC-320 C13 NEMA 5-20R IEC-320 C13 Outlet Number
Networking Protocol Support Connectivity Physical
Dimension (H x W x D)
ronmental
Envi
Humidity Altitude Temperature
Safety Approvals
Certifications
Warranty
Product Warranty
12 ft/3.65 m 10 ft/3.05 m 12 ft/3.65 m 10 ft/3.05 m
16A
8
TCP/IP, UDP, DHCP, SNMP, HTTP
RJ45
1.73" x 17.05" x 4.41"/44mm x 433mm x 112mm
0 to 95% Non-condensing
14700 ft/4500 m
32 to 104/0 to 40
UL 60950,
FCC Class A
UL 60950, CE,
FCC Class A
FCC Class A
3 years repair or replace
02C 023-CEI02C 023-CEI
3
4
Loading...