Model List ......................................................1
Package Contents ........................................ 2
Safety Precautions ....................................... 2
Installation .................................................... 3
Horizontal Installation .......................
Vertical Installation with Brackets ... Vertical Installation ­Keyhole Mounts (0U models only) ...
Cord Retention Tray installation .......
Meter Configuration ..........................
Electrical Installation ........................
Troubleshooting ........................................... 6
Product Features
Technical Specification ................................ 7
Basic Series ....................................... 7
Metered Series ...................................
9
Basic Series (0U) ...............................
10
Metered Series (0U) ...........................
11
Warranty & Service .......................................12
3 4
5 5 5 6
Page 3
Model List:
Basic Series:
PDU15B8R PDU15B10R PDU15B12R
PDU20B8R PDU20B10R PDU20B12R
PDU20BT8R PDU20BT10R PDU20BT12R
PDU15B2F8R PDU15B2F10R PDU15B2F12R PDU15B4F8R PDU15B4F10R PDU15B4F12R PDU15B6F8R PDU15B6F10R PDU15B6F12R
PDU20B2F8R PDU20B2F10R PDU20B2F12R PDU20B4F8R PDU20B4F10R PDU20B4F12R PDU20B6F8R PDU20B6F10R PDU20B6F12R
PDU20BT2F8R PDU20BT2F10R PDU20BT2F12R PDU20BT4F8R PDU20BT4F10R PDU20BT4F12R PDU20BT6F8R PDU20BT6F10R PDU20BT6F12R
Metered Series:
PDU15M2F8R PDU15M2F10R PDU15M2F12R
PDU20M2F8R PDU20M2F10R PDU20M2F12R
PDU20MT2F8R PDU20MT2F10R PDU20MT2F12R
Basic Series (0U):
PDU15BV14F PDU15BV16F PDU15BV20F PDU15BV28F PDU15BV32F
PDU20BV14F PDU20BV16F PDU20BV20F PDU20BV28F PDU20BV32F
PDU20BVT14F PDU20BVT16F PDU20BVT20F PDU20BVT28F PDU20BVT32F
Metered Series (0U):
PDU15MV20F PDU15MV26F PDU15MV32F
PDU20MV20F PDU20MV26F PDU20MV32F
PDU20MVT20F PDU20MVT26F PDU20MVT32F
PDU Naming Convention:
1. Amperage:
2. Series:
3. Rack Space:
4. Input Voltage:
5. Plug Type:
6. Outlet Number Front
7. Outlet Number Rear
8. Network Management
PDU XX M V HV T F R NET
1 2 3 4 5 6 7 8
Amperage – 15A, 20A, 30A B: =Basic M: =Metered SW: = Switched NULL: =Horizontal V:= Vertical NULL: =120V HV:= High Voltage – 208V to 250V NULL: =NEMA 5-15P / 5-20P T: = Twist (NEMA L5-L6 Plug) IEC:= (IEC C14/C20) Number of Outlets followed by F – Example 8F Number of Outlets followed by R – Example 8R NET
For inf ormation on Cyberpower products, visit www.cyberpower.com
1
Page 4
Check
Before using, please check to ensure the package contains all the items shown above. If there are missing parts please contact CyberPower technical support at www.cyberpower.com or call 1-877-297-6937.
Safety Precautions ­Read
the following before installing or operating
the Power Distribution Unit (PDU):
1. CAUTION! Use ONLY the supplied hardware (including screws, pegs and cord retainer clips) to attach the mounting brackets. Using different hardware or improper installations may cause damage that is NOT covered by this warranty.
2. The PDU must only be plugged into a three-wire, grounded outlet on a circuit protected by a fuse or circuit breaker. Connection to any other type of power outlet may result in a shock hazard.
3. Do not use extension cords or adapters with this PDU.
4. Never install a PDU, or associated wiring or equipment, during a lightning storm.
5. Check that the power cord, plug, and socket are in good condition.
6. CAUTION! To prevent the risk of fire or electric shock, this PDU
should be
installed in a temperature and humidity controlled indoor area free of conductive contaminants. Do not install this PDU where excessive moisture or heat is present.
For inf ormation on Cyberpower products, visit www.cyberpower.com
2
Package Contents
PDU (1)
Cord Retention Tray (
1/2/3/4 pcs - varies by model)
Horizontal Installation Used (1 set)
Vertical Installation Used (1 set)
Mounting Brackets
Vertical Mounting Brackets (1 set)
(for 0U models only)
Keyhole Mounting Pegs (2pcs) with Screws M4 X 6 (2pcs) (for 0U models only)
Bracket Mounting Screws M4 X 6 (4pcs)
Cable Tie (12/ 15/ 21/ 24/ 30/ 36/
45/ 48/ 57 pcs - varies
by model)
for Cord Retention Tray
Documentation:
User’s Manual
Power
Distribution
Unit
User Manual
Product Registration Card
Product Registration Card
Cord Retention Tray Mounting Screws M3 X 6 (
4/8/12/16 pcs - varies by model)
Ground Screw M4 X 6 (1 pcs)
Page 5
Installation
Horizontal Installation (1U models only)
Step 1 – Mounting bracket installation
Install the screws (M4 X 6) in holes diagonal from each other.
Step 2 – PDU Mounting
Install the PDU using fasteners compatible with the rack.
For inf ormation on Cyberpower products, visit www.cyberpower.com
3
Page 6
Vertical Installation with Brackets
Step 2 – PDU Mounting
Install the PDU using fasteners compatible with the rack.
Vertical Installation with Brackets (0U models only)
Step 1 – Mounting bracket installation
Attach the Vertical Mounting Brackets to the PDU with the 4 supplied Bracket Mounting Screws (M4 X 6).
Step 2 – PDU Mounting
Install the PDU using fasteners compatible with the rack.
For inf ormation on Cyberpower products, visit www.cyberpower.com
4
Step 1 – Mounting bracket installation
Install the screws (M4 X 6) in holes diagonal from each other.
Page 7
Vertical Installation with Keyhole Mounts (0U Models)
Align the the Keyhole Mounts to the Keyhole Slots on the rack. Insert and slide down to lock firmly into place.
Step 2 – PDU Mounting
Step 1 – Keyhole Mount installation
Attach the Keyhole Mounting Pegs to the PDU with the 2 supplied Bracket Mounting Screws (M4 X 6).
For inf ormation on Cyberpower products, visit www.cyberpower.com
5
Cord Retention Tray installation (Optional for both horizontal and vertical installations)
Attach the Cord Retention Tray to the PDU with the 4 supplied Cord Retention Tray Mounting Screws (M3 X 6). Tighten the Cord Retention Tray with the screw on it.
Use the Cable Ties provided to fasten each power cord to the Cord Retention Tray.
Meter Configuration
Use a screwdriver to gently remove the LED Meter. Rotate the LED Meter 90 degrees, and insert back into the PDU.
!
Note
Depending on installation method (vertical or horizontal), the LED Meter may need to be rotated, before installation, for proper orientation.
Adjust the length of the Cord Retention Tray till the screw hole on the Tray and PDU are aligned.
Page 8
Electrical Installation
Ensure that the plug type of your PDU unit (e.g. NEMA 5-15P, NEMA 5­20P, NEMA L5-30P) matches the wall receptacle type that you are using.
Step 1 – Receptacle evaluation
PDU must be plugged into a three-wire, grounded wall receptacle only. The wall receptacle must also be connected to an appropriate branch circuit/main with fuse or circuit breaker protection. Connection to any other type of wall receptacle may result in a shock hazard.
CAUTION!!
Step 2 – Plug the PDU into the wall receptacle
Step 3 – Attach equipment
Before attaching equipment, it is important to calculate the total load that you will be placing on the PDU. It is extremely important not to exceed the PDU's maximum current load (as outlined in the Specifications section). In order to determine your total load, simply add up the amperage of your devices and ensure that it does not exceed the unit’s capacity.
Troubleshooting
Problem Possible Cause Solution
PDU Outlets do not provide power to connected equipment
1. Open breaker
2. Loose power cord
Reset Breaker check if plug is completely connected. If the problem remains contact tech support.
Amperage displayed on Amperage Meter exceeds the unit’s capability (Metered type only)
1. Overload
2. Amperage meter is damaged
The meter will flash when overloaded. Reduce the load on the PDU until the overload is gone. If the problem remains contact tech support.
Circuit breaker has tripped
1. Sustained overload
2.
Excessive ambient or
internal temperatures.
3. Faulty breaker
Reset Breaker. If the problem remains contact tech support.
For inf ormation on Cyberpower products, visit www.cyberpower.co m
6
Page 9
Basic Series
Product Features
Front View
Back View
A B
A. Mounting Bracket B. Back Outlets C. External Site Ground
A. Mounting Bracket B. Circuit Breaker
A B C D
D. AC Power Cord E.
EE
D. AC Power Cord E. Cord Retention Tray
Screw Holes
EE
Technical Specifications
For inf ormation on Cyberpower products, visit www.cyberpower.com
7
Model Name
PDU15B8R PDU15B10R PDU15B12R
PDU20B8R PDU20B10R PDU20B12R
PDU20BT8R PDU20BT10R PDU20BT12R
Input
Voltage
Max current
15 A
Circuit Breaker 15 A
Plug Type NEMA 5-15P NEMA 5-20P NEMA L5-20P
Output
Voltage
Current 15 A
Outlet Type NEMA 5-15R
Indicators
LED Indicators
Meter Readout
Physical
Environmental
Humidity
Altitude
Temperature
Safety Approvals
Certifications
Warranty
ETL (test followed UL 1363)
RoHS
Lifetime
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% N
on-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
N/A
17.5" x 1.5" x 1.75" / 44.5 x 3.81 x 4.45 cm
15 ft
N/A
100 ~ 125 V
20 A
NEMA 5-20R
100 ~ 125 V
20 A
20 A
Power Cord Length
Dimension (WxDxH)
Page 10
Basic Series
Product Features
Front View
Back View
A B C D
A B
C
A. Mounting Bracket B. Back Outlets C. External Site Ground
A. Mounting Bracket B. Circuit Breaker C. Front Outlets
D. AC Power Cord E. Cord Retention Tray
Screw Holes
EE
Technical Specifications
For inf ormation on Cyberpower products, visit www.cyberpower.co m
8
Model Name
PDU15B2F8R PDU15B2F10R PDU15B2F12R PDU15B4F8R PDU15B4F10R PDU15B4F12R PDU15B6F8R PDU15B6F10R PDU15B6F12R
PDU20B2F8R PDU20B2F10R PDU20B2F12R PDU20B4F8R PDU20B4F10R PDU20B4F12R PDU20B6F8R PDU20B6F10R PDU20B6F12R
PDU20BT2F8R PDU20BT2F10R PDU20BT2F12R PDU20BT4F8R PDU20BT4F10R PDU20BT4F12R PDU20BT6F8R PDU20BT6F10R PDU20BT6F12R
Input
Voltage
Max current 15 A
Circuit Breaker 15 A
Plug Type NEMA 5-15P NEMA 5-20P NEMA L5-20P
Output
Voltage
Current 15 A
Outlet Type NEMA 5-15R
Indicators
LED Indicators
M
eter Readout
Physical
Environmental
Humidity
Altitude
Temperature
Safety Approvals
Certifications
Warranty
ETL (test followed UL 1363)
RoHS
Lifetime
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
N/A
17.5" x 2.25" x 1.75" / 44.5 x 5.72 x 4.45 cm
N/A
100 ~ 125 V
20 A
NEMA 5-20R
100 ~ 125 V
20 A
20 A
15 ft
Power Cord Length
Dimension (WxDxH)
Page 11
Metered Series
Product Features
Front View
Back View
A B C D
A B
C D
A. Mounting Bracket B. Back Outlets C. External Site Ground
A. Mounting Bracket B. Circuit Breaker C. LED Meter Readout
D. Front Outlets
D. AC Power Cord E. Cord Retention Tray
Screw Holes
EE
Technical Specifications
For inf ormation on Cyberpower products, visit www.cyberpower.co m
9
Model Name
PDU15M2F8R PDU15M2F10R PDU15M2F12R
PDU20M2F8R PDU20M2F10R PDU20M2F12R
PDU20MT2F8R PDU20MT2F10R PDU20MT2F12R
Input
Voltage
Max Current 15 A
Circuit Breaker 15 A
Plug Type NEMA 5-15P NEMA 5-20P NEMA L5-20P
Power Cord Length
Output
Voltage
Current 15 A
Outlet Type NEMA 5-15R
Fiters & Protection
EMI/RFI Filtration
Surge Suppression
Indicators
LED Indicators
Meter Readout
Physical
Environmental
Humidity
Altitude
Temperature
Safety Approvals
Certifications
Warranty
100 ~ 125 V
20 A
20 A
15 ft
100 ~ 125 V
20 A
NEMA 5-20R
N/A
N/A
N/A
Amperage
17.5" x 2.25" x 1.75" / 44.5 x 5.72 x 4.45 cm
ETL (test followed UL 1363)
RoHS
Lifetime
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
Dimension (WxDxH)
Page 12
For inf ormation on Cyberpower products, visit www.cyberpower.com
10
Basic Series (0U)
Technical Specifications
Product Features
Front View Back View
A
B
C
D
E
E
D
D
D
B
A
A
B
A. AC Power Cord B. Circuit Breaker C. External Site Ground D. Cord Retention Tray Screw Holes E. Front Outlets
A. Bracket Screw Hole B. Keyhole Mount Peg
Screw Holes
Model Name
PDU15BV14F PDU15BV16F PDU15BV20F PDU15BV28F
PDU15BV32F
PDU20BV14F PDU20BV16F PDU20BV20F PDU20BV28F
PDU20BV32F
PDU20BVT14F PDU20BVT16F PDU20BVT20F PDU20BVT28F
PDU20BVT32F
Input
Voltage
Max Current 15 A
Circuit Breaker 15 A
Plug Type NEMA 5-15P NEMA 5-20P NEMA L5-20P
Output
Voltage
Current 15 A
Outlet Type NEMA 5-15R
Indicators
LED Indicators
Meter Readout
Physical
Environmental
Humidity
Altitude
Temperature
Safety Approvals
Certifications
Warranty
Lifetime
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
1.75" x 2.25" x 24" / 4.45 x 5.72 x 60.96
cm
1.75" x 2.25" x 36" / 4.45 x 5.72 x 91.44 cm
1.75" x 2.25" x 48" / 4.45 x 5.72 x 121.92 cm
1.75" x 2.25" x 60" / 4.45 x 5.72 x 152.40 cm
1.75" x 2.25" x 70" / 4.45 x 5.72 x 177.80 cm
ETL (test followed UL 1363)
RoHS
N/A
N/A
NEMA 5-20R
20 A
100 ~ 125 V
20 A
20 A
15 ft
100 ~ 125 V
Power Cord Length
Dimension (WxDxH)
Page 13
Metered Series (0U)
Technical Specifications
Product Features
Front View
Back View
A
B
C
D
E
E
D
D
D
B
A
A
B
F
A. AC Power Cord B. Circuit Breaker C. External Site Ground D. Cord Tray Screws Holes E. Front Outlets F. LED Meter Readout
A. Bracket Screw Hole B. Keyhole Mount Peg
Screw Holes
For inf ormation on Cyberpower products, visit www.cyberpower.co m
11
Model Name
PDU15MV20F PDU15MV26F PDU15MV32F
PDU20MV20F PDU20MV26F PDU20MV32F
PDU20MTV20F PDU20MTV26F PDU20MTV32F
Input
Voltage
Max Current 15 A
Circuit Breaker 15 A
Plug Type NEMA 5-15P NEMA 5-20P NEMA L5-20P
Output
Voltage
Current 15 A
Outlet Type NEMA 5-15R
Indicators
LED Indicators
Meter Readout
Physical
Environmental
Humidity
Altitude
Temperature
Safety Approvals
Certifications
Warranty
100 ~ 125 V
20 A
20 A
15 ft
N/A
100 ~ 125 V
20 A
NEMA 5-20R
ETL (test followed U
L 1363)
RoHS
Lifetime
Operating 0 to 95% Non-condensing
Non-Operating 0 to 95% Non-condensing
Operating 0ft to 10,000ft
Non-Operating 0ft to 50,000ft
Operating 32F to 95F
Non-Operating 5F to 113F
Amperage
1.75" x 2.25" x 48" / 4.45 x 5.72 x 121.92 cm
1.75" x 2.25" x 60" / 4.45 x 5.72 x 152.40 cm
1.75" x 2.25" x 70" / 4.45 x 5.72 x 177.80 cm
Power Cord Length
Dimension (WxDxH)
Page 14
For inf ormation on Cyberpower products, visit www.cyberpower.co m
12
Product Registration
Thank you for purchasing a CyberPower product. Prompt product registration entitles coverage under the Limited Warranty and Connected Equipment Guarantee, and also allows the opportunity to be notified of product enhancements, upgrades, and other announcements.
Registration is quick and easy at www.cyberpower.com under "Support".
Need Additional Help?
Feel free to contact our Tech Support department with installation, troubleshooting, or general product questions.
CyberPower Technical Support
www.cyberpower.com
4241 12th Ave East, Suite 400 Shakopee, MN 55379 Toll-free: (877) 297-6937
Limited Warranty
Read the following terms and conditions carefully before using the CyberPower PDU(the “Product”). By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty (together referred to as this “Warranty”). If you do not agree to the terms and conditions of this Warranty, you should return the Product for a full refund prior to using it.
Who is Providing this Warranty?
CyberPower Systems (USA), Inc. (“CyberPower”) provides this Limited Warranty.
What Does This Warranty Cover?
This warranty covers defects in materials and workmanship in the Product under normal use and conditions.
What is the Period of Coverage?
This Warranty is for as long as the original owner owns the Product.
Who Is Covered?
This warranty only covers the original purchaser. Coverage ends if you sell or otherwise transfer the Product.
How Do You Get Service?
1. Call us at (877) 297-6937 or write to us at Cyber Power Systems (USA), Inc., 4241 12th Ave. E., STE 400, Shakopee, MN 55379 or
send us an e-mail message at claims@cpsww.com for instructions.
2. When you contact CyberPower, identify the Product,
the Purchase
Date, and the item(s) of Connected Equipment. Have information on all applicable insurance
or other resources of recovery/payment
that are available to the Initial Customer and Request a Claim Number.
3. You must provide a purchase receipt (or other proof of the original purchase) and provide a description of the defect.
4. Pack and ship the product to CyberPower and, if requested, the item(s) of Connected Equipment, a repair cost estimate for the damage to the Connected Equipment, and all claim forms that CyberPower provides to you. Show the Claim Number on the shipping label or include it with the product. You must prepay all shipping costs, you are responsible for
packaging and shipment,
and you must pay the cost of the repair estimate.
What Will We Do To Correct Problems?
CyberPower will inspect and examine the Product.
If the Product is defective in material or workmanship, CyberPower will repair or replace it at CyberPower's expense, or, if CyberPower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will refund to you the full purchase price you paid for the Product (purchase receipt showing price paid is required).
Who Pays For Shipping?
We pay when we send items to you; you pay when you send items to us.
Page 15
What Are Some Things This Warranty Does Not Cover?
1. This Warranty does not cover any software that is damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records, or the reinstallation of software.
2. This Warranty does not cover or apply to: misuse, modification, operation or
storage outside environmental limits of the Product or
the equipment connected to it, nor for damage while in transit or in storage, nor if there has been improper operation or maintenance, or use with items not designed
or intended for use with the Product,
such as laser printers, appliances, aquariums, medical or life support devices, etc.
What Are the Limitations?
1. This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets (including compliance with electrical and safety codes of the most current electrical code), without the use of any adapters or other connectors.
2. The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not “daisy-chained” together in serial fashion with any extension cords, another Product or device similar to the Product, surge suppressor, or power tap. Any such installation voids the Limited Warranty.
3. The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license, instruction manual, or warnings provided with the Product and the equipment connected to it.
4. The Product must have been used at all times within the limitations on the Product's VA capacity.
5. The sole and exclusive remedies of the Initial Customer are those provided by this Warranty.
Contact Information
CyberPower Systems, Inc.
4241 12th Ave East, Suite 400 Shakopee, MN 55379 Toll-free: (877) 297-6937
CyberPower is the warrantor under this Limited Warranty. You may also contact CyberPower on the web at www.cyberpower.com
For inf ormation on Cyberpower products, visit www.cyberpower.co m
13
Page 16
K01-0000511-00
Cyber Power Systems, Inc.
www.cyberpower.com
Loading...