OL1500RTXL2UN
SMART APP ONLINE UPS
Prevent business interruptions and safeguard
mission-critical enterprise network equipment.
The CyberPower OL1500RTXL2UN is a rack/tower UPS with double
conversion topology. It provides sine wave output to critical applications and
equipment that require seamless power correction. The Extended Battery
Module (EBM) expands runtime, and Fast Charge Technology restores full
backup power faster. This model comes with an extendable LCD control
panel, Smart Battery Management charging technology, and energy-saving
GreenPower UPS™ ECO Mode.
The OL1500RTXL2UN oers generator compatibility and delivers clean AC
power with zero transfer time. A factory installed RM card allows remote
management and configuration of the UPS via a standard web browser,
command line interface (CLI), or network management system (NMS). Its sine
wave output keeps sensitive equipment working by preventing unnecessary
shutdowns that can occur with simulated sine wave output.
With a $400,000 lifetime connected equipment guarantee and a three-year
warranty, you can trust CyberPower’s commitment to high quality.
SPECIFICATIONS
TYPICAL APPLICATIONS
• Corporate and Enterprise Servers
• Network and Storage Devices
• Edge Closets
• PBX and VoIP Installations
FE ATURES
• 1500VA / 1350W
• Double Conversion Topology
• Sine wave output, zero transfer time
• Configurable Output - 100, 110, 115, 120,
125 V, 50/60 Hz
• GreenPower UPS™ ECO Mode
• RM205CARD for remote monitoring
• 2U Rack Mount/Tower Convertible
• Outlets: (8) NEMA 5-15R
• PowerPanel® Business Edition
Management Software
GENERAL
UPS Topology Double Conversion
Energy Saving Yes, ECO Mode Eciency >9 5%
Energy Star Qualified Yes
INPUT
60 – 69 VAC for 0– 60% load
Input Voltage Range
Frequency Range 40 – 70 Hz (auto sensing)
Input Power Factor 0.99
Cold Start Yes
Plug Type NEMA 5 -15P
Cord Length (ft) 10
Cord Length (m) 3
©2020 Cyber Power Systems (USA), Inc. CyberPower is a registered trademark and brand of Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property
of their respective owners. CyberPower reserves the right to change, without notice, marketing programs, product offerings and specifications. www.cyberpowersystems.com
70 – 79 VAC for 0–70% load
80 – 89 VAC for 0 –80% load
90 – 95 VAC for 0 –90% load
96 – 150 VAC for 0–1 00% load
OUTPUT
VA
Watts
Rated Power Factor 0.9
On Battery Waveform Sine wave
On Battery Voltage 1 00, 110, 115, 120, 125 V ± 2% (configurable)
On Battery Frequency
Harmonic Distortion
Crest Factor 3:1
Outlet s - Total 8
Ou tl et Type NEMA 5 -15R (8)
1,5 00 VA at 120, 125 V
1,3 50 VA at 115, 110 V
1,200 VA at 100 V
1,3 50 W at 120, 125 V
1,215 W at 115, 110 V
1,080 W at 100 V
50/60 Hz ± 0. 25 Hz
(auto-sensing or configurable)
THD < 3% at Linear Load,
< 5% at Non -linear Load
OL1500RTXL2UN
SMART APP ONLINE UPS
SPECIFICATIONS CONT.
OUTPUT - CONT.
Line Mode:
105% to 125% load for 1 min
Overload Protection
Bypass
Transfer Time 0 ms
126% to 15 0% load for 1 0 sec
Battery Mode:
105% to 130% load for 10 sec
131% to 1 50% load for 2 sec
Internal Bypass
(Automatic and Manual)
BAT TERY
Runtime at Half Load 11 minutes
Runtime at Full Load 3.4 minutes
Ba tt er y Type Sealed Lead-Acid
Battery Size 12 V/9A h
Battery Quantity 3
Replacement Battery Cartridge RB1290X3L
Replacement Battery Cartridge
Quantity
Hot Swappable Yes
Typical Recharge Time 4 h (0% to 90%)
Smart Battery Management (SBM)
Mode
Extended Battery Option BP36V60ART2U
1
Yes
SURGE PROTECTION & FILTERING
Surge Protection 1780 J oules, per IEC 6100 0-4-5 Level 3
Phone RJ11 / Ethern et RJ45 1-In / 1-Out (Combo)
EMI/RFI Filtration Yes
MANAGEMENT & COMMUNICATIONS
LCD Multifunction LCD
Rotatable LCD Control Pa nel
Option
Removable LCD Control Pa nel
Option
HID Compliant USB Port Yes
Serial Port Yes
EPO Por t Yes
Dry Contacts Yes
Cables Included USB cable, Serial cable
LED Indicators
Audible Alarms
Software PowerPanel® Business Edition
Upgradeable Firmware Yes
Expansion Slot RMCARD205 pre-installed
Yes
Yes - Requires a separate DB26 Cable
Power On (white)
Line Mo de (green)
Battery Mode (yellow)
Bypass Mode (yellow)
Fau lt (re d)
Replace Battery (red)
Battery Mode
Battery Low
Overload
UPS Fault
PHYSICAL
Form Factor Rack/Tower
Color Black
Enclosure Construction Steel
Mounting Hardware Included Yes
Physical Dimensions - (WxHxD) (cm) 43.18 x 8.89 x 42.93 (cm)
Physical Dimensions - (WxHxD) (in) 17 x 3.5 x 16.9 (in)
Physical Dimensions - (WxHxD) (mm) 432 x 89 x 429 (mm)
Weight (lbs) 39.6
Weight (kg) 17.96
Rack Size 2U
SHIPPING DIMENSIONS
Shipping - Dimensions (WxHxD, in) 21. 5 x 9.14 x 22. 5 (in)
Shipping - Dimensions (WxHxD, mm) 546.1 x 232.16 x 571.5 (mm)
Shipping - Weight (lb) 55.0
Shipping - Weight (kg) 24.9 5
Shipping Dimensions - (WxHxD) (cm) 54.61 x 23.2 2 x 57.15 (cm)
©2020 Cyber Power Systems (USA), Inc. CyberPower is a registered trademark and brand of Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property
of their respective owners. CyberPower reserves the right to change, without notice, marketing programs, product offerings and specifications. www.cyberpowersystems.com