CyberPower OL1500RTXL2U User Manual

Page 1
OL1500RTXL2U SMART APP ONLINE UPS
Prevent business interruptions and safeguard mission­critical enterprise network equipment.
The CyberPower OL1500RTXL2U is a rack/tower UPS with double conversion topology. It provides sine wave output to critical applications and equipment that require seamless power correction. The Extended Battery Module (EBM) expands runtime, and Fast Charge Technology restores full backup power faster. This model comes with an extendable LCD control panel, Smart Battery Management charging technology, and energy-saving GreenPower UPS™ ECO Mode.
The OL1500RTXL2U oers generator compatibility and delivers clean AC power with zero transfer time. Its sine wave output keeps sensitive equipment working by preventing unnecessary shutdowns that can occur with simulated sine wave output.
With a $400,000 lifetime connected equipment guarantee and a three-year warranty, you can trust CyberPower’s commitment to high quality.
TYPICAL APPLICATIONS
• Corporate and Enterprise Servers
• Network and Storage Devices
• Edge Closets
• PBX and VoIP Installations
FE AT U R E S
• 1500 VA / 1350 W
• Double Conversion Topology
• Sine wave output, zero transfer time
• Configurable Output - 100, 110, 115, 120, 125 V, 50/60 Hz
• GreenPower UPS™ ECO Mode
• Expansion Slot
• 2U Rack Mount/Tower Convertible
• Outlets: (8) NEMA 5-15R
• PowerPanel® Business Edition Management Software
SPECIFICATIONS
GENERAL
UPS Topology Double Conversion
Energy Saving Yes, ECO Mode Eciency >95%
Energy Star Qualified Yes
INPUT
Nominal Voltage 100 V to 125 V
60 V to 69 V, 0% to 60% load
Frequency Range 40 Hz to 70 Hz (auto-sensing)
Power Factor 0.99
Cold Start Yes
70 V to 79 V, 0% to 70% load 80 V to 89 V, 0% to 80% load 90 V to 95 V, 0% to 90% load 96 V to 150 V, 0% to 100% load
INPUT - CONT.
Plug Ty p e NEMA 5-15P
Cord Length (ft) 10
Cord Length (m) 3
OUTPUT
VA
Watts
Power Factor 0.9
Waveform (Battery Mode) Sine wave
Nominal Voltage (Battery Mode)
1500 (1.5 kVA) at 120, 125 V 1350 (1.35 kVA) at 115, 110 V 1200 (1.2 kVA) at 100 V
1350 (1.35 kW) at 120, 125 V 1215 (1.215 kW) at 115, 110 V 1080 (1.08 kW) at 100 V
100, 110, 115, 120, 125 V ±2% (configurable)
Page 2
OL1500RTXL2U SMART APP ONLINE UPS
SPECIFICATIONS CONT.
OUTPUT - CONT.
Frequency
ECO Mode Bypass Voltage Range
Harmonic Distortion (T H D)
Crest Factor 3:1
Outlets - Total 8
Outlet Type (8) NEMA 5-15R
Overload Protection
Short Circuit Protection
Bypass
Maintenance Bypass Optional MBP15A6
50/60 Hz ±0.25 Hz (auto-sensing/configurable)
±10%, ±15% (configurable)
<3% at linear load, <5% at non-linear load
Line Mode: 105% to 125% load for 1 min 126% to 150% load for 10 sec Battery Mode: 105% to 130% load for 10 sec 131% to 150% load for 2 sec
UPS output cut o immediately or input fuse / circuit breaker protection
Internal bypass (automatic and manual)
SURGE PROTECTION & FILTERING
Surge Protection 1780 Joules, per IEC 61000-4-5 Level 3
Phone RJ-11 / Ethernet Surge Protection RJ-45
EMI/RFI Filtration Yes
1-In / 1-Out (combo)
MANAGEMENT & COMMUNICATIONS
LCD Multifunction LCD
Rotatable LCD Control Panel Yes
Removable LCD Control Panel Option
HID Compliant USB Port Yes
Serial Port Yes
Emergency Power O (EPO) Port
Dry Contact Port Ye s
Yes, requires DB26 cable (not included)
Yes
Transfer Time 0ms
BAT TE RY
Runtime at Half Load 11 min
Runtime at Full Load 3.4 min
Batte ry Ty p e Sealed lead acid
Battery Size 12 V/9 Ah
Battery Quantity 3
Replaceable Ye s
Cables Included USB cable, Serial cable
Power On (white) Line Mode (green)
LED Indicators
Audible Alarms
Software PowerPanel® Business Edition
Upgradeable Firmware Yes, requires RMCARD205
Expansion Slot
Battery Mode (yellow) Bypass Mode (yellow) Fault (red) Replace Battery (red)
Battery Mode, Battery Low, Overload, UPS Fault
Yes, for optional RMCARD205 or R EL AY I O5 0 0
PHYSICAL
Replacement Battery RB1290X3L
Hot Swappable Yes
Typical Recharge Time 4 h (0% to 90%)
Smart Battery Management (SMB) Mode
Extended Battery Module (EBM)
©2020 Cyber Power Systems (USA), Inc. CyberPower is a registered trademark and brand of Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners. CyberPower reserves the right to change, without notice, marketing programs, product offerings and specifications. www.cyberpowersystems.com
Yes
Optional BP36V60ART2U
Form Factor
Enclosure Construction Steel
Rack Mounting Hardware Included
Physical Dimensions ­(WxHxD) (cm)
Physical Dimensions ­(WxHxD) (in)
Rack / Tower Convertible (Rotatable LCD)
43.18 x 8.89 x 42.93 (cm)
17 x 3.5 x 16.9 (in)
Page 3
OL1500RTXL2U SMART APP ONLINE UPS
SPECIFICATIONS CONT.
PHYSICAL - CONT.
Dimensions (WxHxD, mm) 432x 89x 429 (mm)
Weight (kg) 17. 9 6
Weight (lb) 39.6
Rack Units 2U
SHIPPING DIMENSIONS
Shipping - Dimensions (WxHxD, in)
Shipping - Dimensions (WxHxD, mm)
Shipping - Weight (lb) 55.0
Shipping - Weight (kg) 24.95
21.5 x 9.14 x 22.5 (in)
546.1 x 232.16 x 571.5 (mm)
ENVIRONMENTAL
Operating Temperature 32 °F to 104 °F (0 °C to 40 °C)
Operating Relative Humidity
Operating Elevation 0 ft to 10000 f t (0 m to 3000 m)
Storage Temperature -4 °F to 113 °F (-20 °C to 45 °C)
Storage Relative Humidity 0% to 95% non-condensing
0% to 90% non-condensing
CERTIFICATIONS
Safety
Environmental RoHS Compliant
UL 1778 CSA C22.2 NO.107.3 FCC Part 15 Class B
WARRANTY
Product Warranty 3 Years Limited
Extended 2-Year Warranty Optional WEXT5YR-U4A
Connected Equipment Guarantee
CEG Amount $400,000
Lifetime
Storage Elevation 0 ft to 50000 ft (0 to 15000 m)
Online Thermal Dissipation (100% Load)
ECO Mode Thermal Dissipation (100% Load)
Audible noise at 1.5M from surface of unit
478 BTU/h
207 BTU/h
38 dBA to 55 dBA (0% to 100% load)
©2020 Cyber Power Systems (USA), Inc. CyberPower is a registered trademark and brand of Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners. CyberPower reserves the right to change, without notice, marketing programs, product offerings and specifications. www.cyberpowersystems.com