User Manual
Power
Distribution
Unit
4241 12th Ave E #400,
Shakopee, MN 55379
1-877-297-6937
www.CPSww.com
K01-0000083-00
Table of Contents
Model List ......................................................1
PDU Naming Convention ............................. 1
Package Contents ........................................ 2
Safety Precautions ....................................... 2
Installation .................................................... 3
Horizontal Installation ....................... 3
Vertical Installation with Brackets ...
Vertical Installation Keyhole Mounts (0U models only) ...
Cord Retention Tray installation ......
Meter Configuration ..........................
Electrical Installation ........................ 6
4
5
5
5
Troubleshooting ........................................... 6
Product Features
Technical Specification ............................... 7
Basic Series (1U 20A).........................
Basic Series (1U 30A).........................
Basic Series (0U 10A).........................
Basic Series (0U 20A)........................
Basic Series (0U 30A)........................
Metered Series (0U 20A)
Metered Series (0U 30A)
.................... 12
.................... 13
7
8
9
10
11
Warranty & Service .......................................14
Basic Series:
PDU20BHVT8R
PDU20BHVT10R
PDU20BHVT12R
PDU30BT8F8R
PDU30BT10F10R
PDU20BHVIEC8R
PDU20BHVIEC10R
PDU20BHVIEC12R
PDU20BHVIEC12Ra
PDU30BHVT8R
PDU30BHVT10R
PDU30BHVT12R
Package ContentsModel List:
PDU (1)
Cord Retention Tray
(
1/2/3/4 pcs - varies by model)
Basic Series (0U):
PDU10BVHVIEC16F
PDU10BVHVIEC20F
PDU20BVHVT16F
PDU20BVHVT20F
PDU20BVHVT24F
PDU20BVHVT32F
PDU20BVHVT38F
PDU30BVT14F
PDU30BVT16F
PDU30BVT20F
PDU30BVT28F
PDU30BVT32F
Metered Series (0U):
PDU20MVHVT20F
PDU20MVHVT30F
PDU20MVHVT38F
PDU30MVT24F
PDU30MVT32F
PDU20BVHVIEC16F
PDU20BVHVIEC20F
PDU20BVHVIEC24F
PDU20BVHVIEC32F
PDU20BVHVIEC38F
PDU30BVHVT16F
PDU30BVHVT20F
PDU30BVHVT32F
PDU30BVHVT38F
PDU20MVHVIEC24F
PDU20MVHVIEC30F
PDU20MVHVIEC38F
PDU30MVHVT20F
PDU30MVHVT30F
PDU30MVHVT38F
Mounting Brackets
Horizontal Installation
Used (1 set)
Vertical Installation
Used (1 set)
Bracket Mounting
Screws M4 X 8 (4pcs)
Keyhole Mounting Pegs (2pcs)
with Screws M4 X 8 (2pcs)
(for 0U models only)
Ground Screw M5 X 6 (1 pcs)
Vertical Mounting Brackets (1 set)
(for 0U models only)
Cord Retention Tray
Mounting Screws M3 X 6
(
4/8/12/16 pcs - varies by model)
Cord Retainer Clips (8/10/12/14/16/
20/24/30/32/38 pcs - varies
by model)
for Cord Retention Tray
PDU Naming Convention:
PDU XX M V HV T F R NET
1 2 3 4 5 6 7 8
1. Amperage:
2. Series:
3. Rack Space:
4. Input Voltage:
5. Plug Type:
6. Outlet Number Front
7. Outlet Number Rear
8. Network Management
Amperage – 15A, 20A, 30A
B: =Basic M: =Metered
SW: = Switched
NULL: =Horizontal V:= Vertical
NULL: =120V HV:= High Voltage – 200V to 230V
NULL: =NEMA 5-15P / 5-20P
T: = Twist (NEMA L5-L6 Plug)
IEC:= (IEC C14/C20)
Number of Outlets followed by F – Example 8F
Number of Outlets followed by R – Example 8R
NET
Documentation:
User Manual
Power
Check
Distribution
Unit
User Manual
Before using, please check to ensure the package contains all the
items shown above. If there are missing parts please contact
CyberPower technical support at www.CPSww.com or call 1-877297-6937.
Product Registration Card
Product
Registration
Card
Safety Precautions -
the following before installing or operating
Read
the Power Distribution Unit (PDU):
1. Use only the supplied hardware to attach the mounting brackets.
2. The PDU must only be plugged into a three-wire, grounded outlet on a
circuit protected by a fuse or circuit breaker. Connection to any other type
of power outlet may result in a shock hazard.
3. Do not use extension cords or adapters with this PDU.
4. Never install a PDU, or associated wiring or equipment, during a lightning
storm.
5. Check that the power cord, plug, and socket are in good condition.
6. The socket-outlet shall be installed near the equipment and shall be easily
accessible.
7. CAUTION! To prevent the risk of fire or electric shock, this PDU should be
installed in a temperature and humidity controlled indoor area free of
conductive contaminants. Do not install this PDU where excessive
moisture or heat is present..
1 2
For i nfo rm ation o n C yb erp ow er pr oduct s, vi si t w ww. CPSww. com For i nfo rm ation o n C yb erp ow er pr oduct s, vi si t w ww. CPSww. com