CyberPower Cyberpower UT2200EG UPS Nødstrømforsyning 2200VA 1320W (4x udtag), Cyberpower UT1500EG UPS Nødstrømforsyning 1500VA 900W (4x Schuko) Manual [EN]

Page 1
UT1500EG/UT1500EIG/UT2200EG/UT2200EIG
User’s Manual
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.) CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS. CAUTION! Do not plug the UPS input into its own output. CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. CAUTION! Do not attach a power strip or surge suppressor to the UPS. CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent. CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized
personnel away from batteries. CAUTION! The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary.
CAUTION! Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery. CAUTION! When replacing the batteries, use the same number and type of batteries. CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the
skin and eye.
INSTALLING YOUR UPS SYSTEM
UNPACKING
The box should contain the following: (1) UPS Unitx1; (2) User Manual x 1 PowerPanel® Personal software is available on our website. Please visit www.cyberpower.com
OVERVIEW
The UT1500/2200EG series provide automatic voltage regulation for inconsistent utility power, and provides battery backup during power outages. The UT1500/2200E series ensure consistent power to your computer system.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure that the battery's
2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazzdrive, Tape drive, etc.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wallbranch outlet is protected by a fuse or circuit breaker and does not
4. Press the power switch to turn the unit on. The power on indicator light will illuminateand the unit will "beep".
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep.To correct this, turn the UPS off and unplug at least one piece of
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store your UPS for an extended period, cover it and store with the batteryfullycharged. Recharge the battery every three months to ensure battery life.
1. Power Switch Press the switch for 2 seconds to turn the UPSON or OFF. Alarm setting: The audible alarm can be turned OFF or ON by quickly pressing the POWER button twice. The default setting is for the Alarm On. To turn the Alarm Off, quickly press the power button twice. You will hear two short beeps when the Alarm is turned off. To turn the Alarm back on, quickly press the power button twice. You will hear a single short beep when the Alarm is turned on.
2. Led Indicators The LED indicates the status of UPS. Refer to Definitions for Illuminated LED Indicators section for details.
3. USB Charger Port
The UPS provides charging for external equipment via this port.
4. Battery Backup & Surge Protected Outlets
Provide battery backup and surge protection. They ensure power is provided to connected equipment over a period of time during a power failure.
5. Communication Protection Ports
Communication protection ports will protect any standard modem, fax, telephone line, or network cable.
6. Input Circuit Breaker
The circuit breaker provides optimal overload protection.
7. Input power cord
Connect to utility power.
8. USB Port to PC This port allows connection andcommunicationfrom the USB port on the computer to the UPS unit. The UPS communicates its status to thePowerPanel Personal software.
maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off position.
into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the battery power supplied outlets. The power demands of these devices will overload and possibly damage the unit.
service equipment withlarge electrical demands (e.g. air conditioner, refrigerator, copier, etc. Avoid usingextension cords.
equipment from thebattery power supplied outlets. Wait 10 seconds. Make sure the circuit breaker / fuse is normal and then turns the UPS on.
BASIC OPERATION
and go to the Software Section for free download.
®
Copyright © 2022CyperPower Systems, Inc. All rights reserved. 11F., No.26, Jinzhuang Rd., Neihu Dist., Taipei City 114, Taiwan K01-C000756-00
Page 2
TECHNICAL SPECIFICATIONS
Model
Capacity (VA/W)
UT1500EG UT1500EIG UT2200EG UT2200EIG
1500 / 900 2200 / 1320
Input
Voltage Range
Nominal Frequency
167~295Vac
50/60Hz
Output
On Battery Output Voltage
On Battery Output Frequency
USB Charge Port
Overload Protection
Simulated Sine Wave at 230Vac +/-10%
50/60 Hz+/-1%
1 x Type A + 1 x Type C @ 2.1A (Shared)
Breaker / Fuse
Physical
Total # of UPS Receptacles
Dimensions (Wx H x D)(mm)
Weight (kg)
(4) Schuko or FR (6) IEC (4) Schuko or FR (6) IEC
148 X 178 X 298
9.1 kg 10.8 kg
Battery
Sealed Maintenance Free Lead Acid Battery
Typical Recharge Time
RBP0089 x2 RBP0090 x2
8 Hours
Warning Diagnostics
Indicators
Audible Alarms
On Battery, Low Battery, Overload, Fault
Utility / Battery / Fault
Surge Protection
Network/ Phone/ Fax/ Modem Protection
YES
Communication
PowerPanel® Personal Software
Windows 10/8/7, Windows Server 2016/2012/2008, Linux
Environmental
Operating Temperature
Operating Relative Humidity
0C to 40C
0 to 90%
DEFINITIONS FOR ILLUMINATED LED INDICATORS
LED Light Audible Alarm UPS Status Description
Green
Yellow
Red
ON - ECO Mode The utility is normal. The UPS operates in energy-saving mode.
Slowly Flashing - Charging The utility is normal. The UPS is charging the battery.
ON Beep twice every 30 seconds Battery Mode The UPS is providing battery power.
Flash Rapid Beeping Low Battery The UPS will run out of battery power soon.
ON, Flash once
every 5 seconds
ON, Flash twice
every 5 seconds
ON, Flash 3 times
every 5 seconds
ON, Flash 4 times
every 5 seconds
Flash Constant Tone Overload Warning
Constant Tone Battery Output Short Fault Turn off the UPS and unplug at least one piece of equipment.
Constant Tone Overload Fault
Constant Tone Charger Fault Contact CyberPower for support
Constant Tone Hardware Fault Contact CyberPower for support
Connected equipment exceeds the rating of the unit. Turn off the UPS
and unplug at least one piece of equipment.
Connected equipment exceeds the rating of the unit. Turn off the UPS
and unplug at least one piece of equipment.
TROUBLESHOOTING
Problem Possible Cause Solution
The UPS does not perform
expected runtime.
The UPS will not turn on.
Outlets do not provide power to
equipment
Fuse is blown or breaker is tripped due to overload.
Batteries are not fully charged. Recharge the battery by leaving the UPS plugged in.
Battery is slightly worn out. Contact CyberPower Systems Technical Support.
The unit is not connected to an AC outlet. The unit must be connected to a 220-240V outlet.
The battery is worn out. Contact CyberPower Systems Technical Support.
Mechanical problem. Contact CyberPower Systems Technical Support.
Turn the UPS off and unplug at least one piece connected equipment.
Unplug the power cord of the UPS then replace the blown fuse with a
spare one or press the circuit breaker knob. Connect power cord then
turn the UPS on. Make sure that your spare fuse meets the specification.
Batteries are discharged Allow the unit to recharge for at least 4 hours.
Unit has been damaged by a surge or spike. Contact CyberPower Systems Technical Support.
Copyright © 2022CyperPower Systems, Inc. All rights reserved. 11F., No.26, Jinzhuang Rd., Neihu Dist., Taipei City 114, Taiwan K01-C000756-00