140WattACMobile PowerInverter
UserGuide
Figure1.ProductFeature

Outp ut P owe r 140 Watt s Co nti nuo us
OutputVoltage 120Volts +/-10%
OutputFrequency 60 Hz
Output Wavefo rm Simulated Si ne Wave
Input Voltage 10.8 to 15.8 vo lts
Low Voltage Shutdo wn 10.5 volt
Problem Possible Cause Suggeste d Solutions
No ACoutputpower
(Power indicator i s not
illuminated)
Poor contactwith lightersocket
Automotive electricalsystems
requires ignitio n to be on.
Cars lightersocket fuseblown
Over -he ating
Vehicle s battery below 10.8
volts.
Ensure the i nverter adapter is sec urely
plugged into v ehicle s lighter so cket.
Replace the lig hter socket if neces sary.
Turnthevehicleignitionkeyto the
Accessory position.
Check the ve hicle fuse panel and rep lace
the damaged f use.
Allowinverterto cool down. Ensure that
there is adequat e ventilation aro und the
unitand loadis no morethan 140wattsfor
continuousoperation.
Unplug theinverter andchargethe vehicle
battery.
Short/LongBeep Your vehicle s batteryinput
voltage isbelow than10.8 volt.
Vehicle sbatteryi nput voltage
is higher than 15. 8 volt.
Inverter is over load.
Checkvehicles batteryand ensureits
capacity. Change ve hicle s battery if
necessary.
Check for your v ehicle s battery
manufacturer g uideline.
Reduceload to140 wattsmax to maintain
regulation.
ContactScrew
Spring
ContactPin
Fuse
DecorativeRing
LighterAdapter
CPS140BI contains a f use inside in the Li ghter Adapter (see Figure 2) t o protect the unit against
overloadi ng. If the invert er draws more than 140 watt s, the inter nal fuse may be bl own to prot ect
the in verter, vehi cle bat tery and the connec ted equipment. To replace the f use, pl ease foll ow the
instruc tion bel ow:
1. Unplug the invert er from the power source.
2. Remove t he Contact Scr ew from the Light er Adapter.
3. Replac e the 15 amper e fuse.
4. Reassemble the f use, cont act pin and contac t screw car efully.
5. Ensure all pieces showed i n Figure 2 are instal led i n the sequence shown.
*Note: For in-warrantyunits, the replacement fuse canbe obtained from CyberPower
TechnicalSupport. For out-of-warranty units, thereplacement 15 ampere fuse canbe obtained
from most electronicsupply retailers.
Cyber Pow er Systems, Inc.
5555 12th Avenue Eas t, Suite 110, Shakopee , MN 55379, U.S.A .
TEL: (952) 403 -9500 FAX: (952) 403-0009 Toll-Free: (877 ) 297-6937
E-mail:s ales@cyberpowersystems.com
Web: www.cyberpowersystems.com
Enti re c ont ents co pyri ght2004 Cyber Po wer Systems, Inc.
Allrights reserved. Reproductionin whole orin partwithout permissionis prohibited
K01-BT14000