CyberPower CP825AVR-G, CP600LCD, CP685AVR-G, CP800AVR, CP685AVRLCD-G Battery Replacement Manual

...
Page 1
1 2 3
64 5
Battery Replacement
1. Place the UPS on its top and remove the retaining screw (figure 1).
2. Slide the battery compartment cover completely off of the unit (figure 2).
3. Remove the battery from the compartment and disconnect the battery wires from the battery. Install the replacement battery by connecting the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the battery. (figure 3)
4. Slide the battery compartment cover over the battery and tighten the retaining screw.
5. Charge the unit for 4 – 8 hours to ensure the UPS performs expected runtimes.
MODEL: CP600LCD, CP825LCD, CP800AVR, CP685AVR-G,
CP825AVR-G, CP685AVRLCD-G, CP825AVRLCD-G, AVRG750U, AVRG900U, AVRG750LCD, AVRG900LCD
1. Place the UPS on its side and locate the battery compartment cover on the bottom of the UPS. Remove the four (4) retaining screws and pull the battery compartment cover off the UPS (figure 1 & 2).
2. Remove the battery from the compartment and disconnect the battery wires from the batteries. Install the replacement batteries by connecting the red wire and black wire to the same color wires from the battery pack. Put the battery pack into the compartment (figure 3).
3. Slide the battery compartment cover over the battery and tighten the retaining screw. Charge the unit for 4 – 8 hours to ensure the UPS performs expected runtimes.
MODEL: CP850AVRLCD, CP1000AVRLCD
Intelligent LCD Series, AVR Series
1
2
3
1. Remove the front panel of the UPS.
2. Pull out both round knobs and remove the battery compartment cover completely off of the unit.
3. Remove the batteries from the compartment.
4. Disconnect the battery wires from the batteries.
5. Install the replacement batteries by connecting the wire bundle (composed of one red wire and one black wire) to the connector from the battery pack. Put the batteries back into the compartment.
6. Re-install the battery compartment cover and push both round knobs back into place. Put the front panel back on the UPS.
7. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge.
MODEL: PR750LCD
Smart APP SINEWAVE Series
1. Place the UPS on its side to locate and rem ove the front panel retaining screws from the bottom of the UPS.
2. Slide the cover (front panel) towar ds the bottom of the UPS.
3. Remove it from the unit.
4. Disconnect the cable located at the top of t he cover.
5. Disconnect the battery wires from the batteries.
6. Remove the batteries from the compartm ent.
7. Install the replacement batteries by connecting the red and black wires to the same color wires from the battery pack. Put the battery pack back into the compartment.
8. Replace the battery compartment cove r and tighten the retaining screw. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.
1. Remove the right side front panel.
2. Remove the three retaining screws for the cable protection cover and remove th
e cover.
3. Disconnect the black and red cable.
4. Remove the one retaining screw holding t he battery pack in place.
5. Remove the battery pack.
6. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse order of the p revious steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.
MODEL: CP900AVR, CP1200AVR, CP1500AVRT, CP1285AVRLCD, CP1350AVRLCD, CP1500AVRLCD
1. Remove the right side front panel.
2. Remove the three retaining screws for the cable p rotection cover and remove the cover .
3. Remove the two retaining screws from the cable connectors.
4. Disconnect the black and red cable.
5. Remove the four retaining screws holding the battery pack in place.
6. Remove the battery pack.
7. Install the new battery pack.
Assemble the screws, cover, cable an d front panel in the rever se order of the previous steps. Charge the unit for 4-8 hours to ensure the UP S performs expected runtimes.
1. Remove the right side front pan el.
2. Remove the two retaining screws for the cable protection cover and remove the cover.
3. Disconnect the black and red cable.
4. Remove the four retaining screws holding the battery pack in place.
5. Remove the battery pack.
6. Install the new battery pack. Assemble the scre ws, cover, cable and front panel in the reverse or der of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.
MODEL: OR1500LCDRM2U, OR2200LCDRM2U, OR1500LCDRTXL2U, OR2200LCDRTXL2U
MODEL: CPS1500AVR
AVR Series
MODEL: OR500LCDRM1U, OR700LCDRM1U, OR1000LCDRM1U,
OR1500LCDRM1U
Smart APP Intelligent LCD Series
1
3
2
1 2 3
64 5
1 2
4 5
3
4
1 2 3
5 6
W ARNI NG
BATT
BATTERY
USING
!
ON
POWER
LOA D
AVR
WARNING
LOA
D
BATT
ON
POWER
AVR
BA T TERY
US ING
!
WARN IN G
LOA D
B A T T
O N
P O W E R
AV R
B AT T E RY
US I NG
!
W ARNING
B A TT
USING
!
LOA D
ON
POWER
AVR
BATTERY
B AT T E RY
AV R
P OW E R O N
L O A D
!
U S IN G
B AT T
WA RNI NG
1 2
4 5
3
R
R
750VA
1 2
4
3
1 2
43
R
1. Remove the front panel of the UPS.
2. Remove two screws from the battery compartment cover and slide the cover completely off of the unit.
3. Remove the batteries from the compartment. Disconnect the battery wires from the batteries.
4. Install the replacement batteries by connecting the wire bundle (composed of one red wire and one black wire) to the connector from the battery pack.
5. Put the batteries back into the compartment. Re-install the battery compartment cover and tighten the retaining screws. Put the front panel back on the UPS.
6. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge.
MODEL: PR1000LCD
1. Remove the front panel of the UPS.
2. Remove two screws from the battery com partment cover and slide the cover completely off of the unit.
3. Remove the batteries from the compartment . Disconnect the battery wires from the batteries.
4. Install the replacement batteries by connecting the wire bundle (composed of one red wire and one black w ire) to the connector from the battery pack.
5. Put the batteries back into the compartment. Re-install the battery compartment cover and tighten the retaining screws. Put the front panel back on the UPS.
6. Connect to AC power and charge the ne w batteries for up to 16 hours to insure a full charge.
MODEL: PR1500LCD
1
3
42
1. Remove the right side front pan el.
2. Remove the two retaining screws for the cable protection cover and remove the cover.
3. Disconnect the black and red cable.
4. Remove the one retaining screw holding the battery pack in place.
5. Remove the battery pack.
6. Install the new battery pack. Assemble the scre ws, cover, cable and front panel in the reverse sequence of the above steps. Charge the unit for 4-8 hours to ensure the UPS performs expected r untimes.
MODEL: PR750LCDRM1U, PR1000LCDRM1U
1 2
4 5
3
1. Remove the right side front pan el.
2. Remove the two retaining screws for the cable protection cover and remove the cover.
3. Disconnect the black and red cable.
4. Remove the four retaining screws holding th e battery pack in place.
5. Remove the battery pack.
6. Install the new battery pack. Assemble the scre ws, cover, cable and front panel in the reverse or der of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected r untimes.
MODEL: PR1500SWRM2U, PR2200SWRM2U
WARNING
BAT T
BAT T ERY
U SI NG
!
ON
POWE R
LO
A D
AVR
WAR N
IN G
LOAD
BATT
ON
P OWER
AVR
BAT T ERY
U SING
!
W ARNING
L O A D
BAT
T
ON
POW ER
AVR
BATT ERY
US IN G
!
WA RN ING
BAT T
USING
!
LOAD
ON
POWE R
AVR
BATT ERY
BATTER Y
AV R
PO WE R ON
LOA D
!
US IN G
B AT T
W AR NING
1 2
4 5
3
1. Remove the front panel of the UPS and two scre ws from the battery compartment cover and slide the cover completely off of the unit.
2. Pull out the battery pack on the outside from the compartme nt. Disconnect the battery connector from the batteries.
3. Before removing the battery pack on the ins ide, unlock the cable tie and pull out the battery wires. Disconnect the battery connector from the batteries.
4. Install the replacement battery pack on th e inside by connecting the wire bundle connector (composed of one red wire and one black wire) to the connector from the battery pack. Lock the battery wir es back with the cable tie.
5. Install the replacement batteries on the outside b y connecting the wire bundle connector (composed of one red wire and o ne black wire) to the connector from the battery pack. Put the batter
y pack on the outside
back into the compartment.
6. Re-install the battery compartment cover and tighten the retain ing screws and put the front panel back on the UPS.
7. Connect to AC power and charge th e new batteries for up to 16 hours to insure a full charge. Note: The battery pack on the outside has a fuse, while the battery pack
on the inside does not.
MODEL: PR2200LCD, PR3000LCD
1 2 3 4
Page 2
7
10
8 9
11
K01-0000611-01
FTTx Series
1. Remove the battery cover.
2. Disconnect battery cable connector to remove battery.
3. Replace with new battery and re-connect the battery connector.
4. Make sure battery is fixed properly in the compartment and close the battery cover.
MODEL: CSN27U12V-NA2, CSN27U12V-NA3,
CSN27U12V-NA3-G, CSN27U12V-XL
1 2 3
1. Slide off the battery cover at the back of t he DTC36U12V unit.
2. Remove the battery from the enclosure.
3. Disconnect both battery cable connectors.
4. Install the new battery by connecting the red lead to the positive terminal and the black lead to the negative terminal.
5. Slide the battery back into the nor mal operation.
6. Replace battery cover to resume normal operation.
MODEL: DTC36U12V-NA3-G
1 2 3
1. Remove the case screw.
2. Open the battery cover.
3. Loosen the battery strap.
4. Disconnect battery cable connector to remove battery.
5. Replace with new battery and re-connect the battery connector.
6. Tighten the battery strip
7. Close the battery cover and lock the case screw.
MODEL: CS24C12V2-E
1 2 3
1. Remove the six retaining screws, and remove the front panel from the UPS.
2. Remove the two retaining screws for the cable protection cover and remove the cover.
3. Remove the two retaining screws from the cable connectors.
4. Disconnect the black and red cable.
5. Remove the three retaining screws holding the battery pack in place.
6. Remove the battery pack.
7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.
MODEL: PR1000LCDRTXL2Ua, PR1500LCDRTXL2U, PR2200LCDRTXL2U, PR3000LCDRT2U, PR3000LCDRTXL2U
654
1 2 3
1. Remove the right side front panel.
2. Remove the three retaining screws for the cable protection cover and remove the cover.
3. Remove the two retaining screws from the cable connectors.
4. Disconnect the black and red cable.
5. Remove the four retaining screws holding the battery pack in place.
6. Remove the battery pack.
7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.
MODEL: OR1500PFCRT2U, OR2200PFCRT2U
4
1 2 3
5 6
PFC SINEWAVE Series
1. Turn the UPS on its side. Remove the retaining screw located on the bottom of the UPS.
2. Slide the battery compartment cover completely off of the unit.
3. Remove the batteries from the compartmen t.
4. Disconnect the battery wires from the batteries .
5. Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors fro m the battery pack. Put the batteries back into the compartment.
6. Slide back the battery compartment cover and tighten the retaining screw. Recharge the UPS for 8-16 hours to fully charge the battery.
MODEL: CP850PFCLCD, CP1000PFCLCD
3 4
1
2
1. Turn the UPS on its side. Remo ve the front panel retaining screws located on the bottom of the UPS.
2. Slide the battery compartment cover (front panel) completely off of the unit.
3. Remove the batteries from the compartmen t.
4. Disconnect the battery wires f rom the batteries.
5. Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors from the battery pack. Put the batteries back into the compartment.
6. Slide back the battery compartment cover and tighten the retaining screws. Recharge the UPS for 8-16 hours to fu lly charge the battery.
MODEL: CP1350PFCLCD
1
3 4
2
1. Turn the UPS on its side. Remo ve the front panel retaining screws located on the bottom of the UPS.
2. Slide the battery compartment cover (front panel) completely off of the unit.
3. Remove the batteries from the compartmen t.
4. Disconnect the battery wires f rom the batteries.
5. Install the replacement batteries by connecting the wire bundle (composed of one red wire and one black wir e) to the connector from the battery pack. Put the batteries back into the compartment.
6. Slide back the battery compartment cover and tighten the retaining screws. Recharge the UPS for 8-16 hours to fu lly charge the battery.
MODEL: CP1500PFCLCD
1
3 4
2
1 2
4 5
3
1. Remove the front panel.
2. Remove the two retaining screws of the cable protection cover and remove the cover.
3. Pull the plastic sticker out slowly to re move the battery module.
4. Put the new battery modules back into the compar tment.
5. Tighten the screws and replace the cable protection cover an d the front panel.
MODEL: PR5000LCDRTXL5U, PR6000LCDRTXL5U
1. Remove the right side front panel.
2. Remove the three retaining screws for the cable pr otection cover and remove the cover.
3. Remove the two retaining screws from the cable connectors.
4. Disconnect the black and red cable.
5. Remove the four retaining screws holding the battery pack in place.
6. Remove the battery pack.
7. Install the new battery pack. Assemble the screws, cov er, cable and front panel in the reverse order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected runtimes.
MODEL: PR1000LCDRT2U, PR1000LCDRTXL2U, PR1500LCDRT2U, PR2200LCDRT2U, PR3000SWRM2U
21
!
3
4
5
6