Cybernet CyberMed H22, CyberMed N22 User Manual

CyberMed H22/N22
All-in-one Medical Panel PC
User’s M anual
Rev: V1.1
Copyright©,2012. All rights reserved
All other bra nd n ame s a re re gistered trade ma rk s of th e ir re spe ctive owners.
WMP-226/227 Us er’s Manual
ii
The information contained in this document is subject to change without notice
CyberMed H22/N22 User’s manual
iii
Version Change History
Date
Version
Description
Remark
2012/7/6
1.0
First release
Cosa Huang
2012/8/20
1.1
Update battery spec
James.Chiu
CyberMed H22/N2 2 User’s man ual
iv
Acknowledgments
Intel® 2nd generation Core i and Celeron are registered
trademarks of Intel® Corporation.
IBM, PC/AT, PS/2 are trademarks of International Business
Machines Corpora tion.
Microsoft
®
Wind ows is a registe red tradema rk of Micros oft
®
Corporation.
RTL is a trademark of Realtek Sem i-Conductor Co., Lt d . C&T is a trademark of Chips and Technologies, Inc. UMC is a tr a d em a rk of United Mic roelectr onics Corporati on. ITE is a trademark of Integrated Tec h no logy Ex p ress, In c. VIA is a trademark of VIA Technology, Inc. Award is a registered trad e ma rk of Award So ftw a re
International, Inc.
PS/2 is a trademark of International Business Machines
Corporation.
Intel is a trademark or registered trademark of Intel
Corporation.
Microsoft Windows is a registered trademark of Microsoft
Corporation.
Winbond is a registered trademark of Winbond Electronics
Corporation.
All other product n ames or trad emarks are properties of their resp ect i v e owner s.
CyberMed H22/N22 User’s manual
v
FCC Class B
This equipm ent has been tested and found to com ply with the limits for a Class B digital device, pursuant to Par t 18 of the FCC Rules. These limits are designed to provide r easonabl e pr otection against harmf ul interference when the equipment is operated in a residential environment. This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with this user manual, it may cause harmf ul interference to radio communica tions. Note that ev en when this equipment is installed and used i n accordance with thi s user manual , t her e is sti ll no guar antee that interference will not occur. If this equipment is believ ed to be causi ng harmf ul interfer ence to radio or tel ev ision reception, this can be determined by turning the equipm ent on and off. If interference is occur r ing, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna  Increase the separation between the equipment and the receiver  Connect the equipment to a power outlet on a circuit different from
that to which the r eceiver is connected
Consult the dealer or an experienced radio/TV technician for help
Warning:
Any chan ges or modifications made to the equipment which are not e xpres sly a ppro ved b y the rele vant s tand ard s autho rit y cou ld void your authority to operate the equipment.
To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth.
Do not modify this equipment without authorization of the manufacturer.
CyberMed H22/N2 2 User’s man ual
vi
Safety Instructions
Intended use
The CyberMed H22/N22 is intended to serve as a medical monitor which i s de signed for ge neral purpose for hospital environm ent and fo r d iagno sis. It co u ld b e used fo r S u rgical, R a d io lo g y, P A CS (Picture Archiving Communication Systems), LIS (Lab Information Systems) and Electronic Medical Record purpose. It shall no t be used for life-supporting system. WARNING: Critical diagnostic decision must not be based solely on images displayed by this device
Greeting & Setup
Thank yo u for pur c ha sing the CyberMed H22/N22 unit. We wis h that this u nit wil l be d urable a nd re liable in prov iding y our medical application needs. P le a se follow th e instructions below to ensure the unit continues to ha ve high pe rf o rmance.
Unpacking
After opening the carton, there will be a medical pa nel PC unit with an accessory box. Examine the contents to see if there are damages to the unit and if all accessories are present.
Setting up
Please read this manual carefully and remember to keep this manual for future reference.
Safety Instructions & Cleaning
The unit has undergone various tests in order to comply with safet y s tanda rd s. I nappr o p riate use of t he open fra me uni t ma y be dangerous. Please remember to follow the instructions below to insure your safety during the installation and operating process.
Transporting & Pl aceme nt of unit
1. When moving the unit on a cart; be very cautious. Quick stops, excessive forces and uneven surfaces may cause the cart to overturn thus risking the unit to fall to the ground.
CyberMed H22/N22 User’s manual
vii
2. If the medical panel PC unit does fall to the ground, immediate ly turn the po wer off a nd disconnect cords. Then contact a service technician for repairs. Continual use of the unit may result cause a fire or electric shock. Also, do not repair the unit on your own.
3. Having two or more people transporting the displ ay uni t is recommended. In addition, when installing the unit by sus p en ding it also req uires tw o or more people .
4. Before suspending the unit, make sure the mate rial used for suspension is sturdy and stable. If not properly suspended, the display unit may fall and cause serious injury to people standing nearby as well as to the unit itself.
5. If you w ish to mo u n t the disp lay un it, rem e mb er to use only the m o u nt ing har d w ar e recomme nd e d by t he manufacturer.
Electrical and Power Source Related
1. This medical panel PC unit must operate on a power source as shown on the specification label. If you are not sure what type of power supply used in the area, consult your dealer or local p ow e r su p p lier.
2. The power cords must not be da maged. Appl ied pressure, added heat, and tugging may damage the power cord.
3. The power cord must be routed properly when setup takes place. We adv ise t hat this aspe ct measur e is to prevent people from step pin g on the cords or while the unit is suspended to prevent flying objects from getting tangled with the unit.
4. Do not overload the AC outlets or extension cords. Electrical shocks or fires may occur from overloading.
5. Do not touch the power s ource during a thunderst orm.
6. If your hands are wet, do not touch the plug.
7. Use your thumb and index f inger, grip firmly on the power cord to disconnect from the electrical socket. By pulling the power cord, may result in damaging it.
CyberMed H22/N2 2 User’s man ual
viii
8. If the unit is not going to be in use for an extended period of time, remember to disconnect the unit.
9. The medical panel PC unit use s voltage between 100-240VAC. C o n nect the u n it to a p o w e r sour ce w it h the same numerica l value as shown. P lease use o nly the power cord provided by the dealer to ensure safety and EMC compliance.
Various Fa ctors of Environment
1. Do not inser t ob j ects into the op e n ings.
2. Do not have liquid s s eep into the internal areas of the medical panel PC unit.
3. Having liquid s seep in or inserting objects into the unit may result in electric shocks from taking and/or short circuiting the internal parts.
4. Do not pl a ce the medical panel P C unit in the pres ence of high mo isture areas .
5. Do not install the medical panel PC u nit in a wet environment.
6. Do not place near unit near heat generating sources.
7. Do not place the unit in a location where it will come in contact with fumes or steam.
8. Remember to keep the medical panel PC unit away from the presence of dust.
9. If wate r has f low in or see p in, im media te ly disc onne ct the open frame unit. Then contact a service technician for repairs.
Ventilation Spacing
1. Do not cove r or block the openings on th e t op an d b a ck sides o f the display unit. Inad equate ventila tion may cause overheating thus reducing the lifespa n of the unit.
2. Unless p roper ve ntila tion is p rese nt, d o no t p lace unit in a n enclosed area; such as a buil t-in shelf. Keep a minimum distance of 10 cm between the display unit and wall.
CyberMed H22/N22 User’s manual
ix
Cleaning t he uni t
1. Rememb e r to tur n of f the powe r so urc e and to unpl ug t he cord f rom the outlet b ef ore cleaning the unit.
2. Caref ully dismount the unit or bring the uni t d own from suspension to clea n.
3. Please use a dry so ft cloth to clean t he un it.
4. Take a dry clo th and wip e the un it dry . Re memb er to avo id having liquids seep into the internal components and areas of the med ical panel PC unit.
Servicing, Repairing, Maintenance & Safety Checks
1. If the unit is not functioning properly, observe the performance level of the display closely to determine what type of servicing is needed.
2. Do no t atte mpt to rep air t he med ical p anel P C unit on your own. Disassembling the cover exposes users’ to high voltages and other dangerous conditions. Notify and reque st a q ualifie d serv ice te chnicia n for s ervic ing the unit.
3. To avoid risk of electric shock, this equipmen t must only be connected to a supply mains with protective earth.
4. If any of the following situations occur turn the power source off and unplug the unit. Then contact a qualified service tech ni cia n.
(a) A liquid was spilled on the unit or objects have fallen
into the unit. (b) The unit is soaked with liquids. (c) The unit is dropped or damaged. (d) If smoke or strange odor is flowing out of the operating
unit. (e) If the power cord or plug is damaged. (f) When the functions of the unit are dysfunctional.
5. When replaceme nt parts are ne eded for the med ica l pa ne l PC unit, make sure service technicians use replacement parts specified by the manufacturer, or those with the
CyberMed H22/N2 2 User’s man ual
x
same characteristics and performance as the original parts. I f u na utho r iz ed par ts are used it may re sult in starting a fire, electrical shock and/or other dangers.
ISO 7000-0434 : Caution, consult ACCOMPANYING DOCUMENTS.
ISO 7000-1641 : Follow operating instructions or Consult instructions for use.
IEC 6041 7 -50 09 : STAN D-BY.
IEC 60417-5031 : Direct current.
EU-wid e le gisla tion, as implemented in each Memb er State, requ ires that waste electrical an d
elec tron ic p ro duc ts ca r ry ing t he m ar k (l ef t) m us t b e
disp osed of separately from normal househ old waste. This includes monitors and electrical accessories, such as signal cables or power cords.
When you n ee d to di spo se of your d isplay pro d u cts,
please follow the guidance of your local authority, or ask the shop where you purcha sed the prod uct, or if applicable, follow any agreements made between yourself.
The mark on electrical and electronic products only applies to the c u rr ent European Union Memb e r States.
CyberMed H22/N22 User’s manual
xi
When networking with electrical devices, the operator is responsibl e for ensuring that the resulting system meets the requirements set forth by the following standards:
– EN 60601-1 (IEC 60601-1)
Medical electrical equipment Part 1: General requiremen ts for safety
– EN 60601-1-1 (IEC 60601-1-1)
Medical electrical equipment Part 1-1: General requirements for safety Collateral standard: Safety requirements for Medical electrical systems
– EN 60601-1-2 (IEC 60601-1-2)
Medical electrical equipment Part 1-2: General requirements for safety Collateral standard: Electromagnetic compatibility; Requirements and tests
Accessory equ ipm en t con nec ted to the a nalog and digi tal inter faces must be in compliance with the respective nationally harmonized IEC standards (i.e. IEC 60950 for data processing equipment, IEC 60065 for video equipment, IEC 61010-1 for laboratory equ ipment, and IE C 60601-1 for medical equipme n t.) Fur ther mo re al l co nfigurations shall comply with the syst e m s tandard IEC 60601-1-1. Everybody who connects additional equipment to the signal input part or signal output part configures a medical system, and is therefore, responsible that the system complies with the requirements of the sy stem standar d I EC 60 6 01 -1-1. The unit is for exclusive interconnection with IEC 60601-1 certified equipment in the patient environment and IEC 60XXX certified equipment outside of the patient environment. If in doubt, consult the technical services department or your local representative.
CyberMed H22/N2 2 User’s man ual
xii
Caution:
DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW
-20° C (-4° F) OR A BOVE 6 0° C ( 140° F) . T HIS M AY DAMA GE TH E EQUIPMENT.
This equipment shall not be used in life suppo r t sys tems. The user is not to touch SIP/SOPs and the patient at the same
time. Caution – Use suitable mounting apparatus to avoid risk of injury.
The sound pressur e level at the op er a tor’s position according t o IEC 704-1:1982 is no more than 70dB (A).
A) Gro unding reliab ility ca n only b e ac hieved w hen the equipm ent
is connected to an equivalent receptacle marked “Hospital Only” or “Hospital Grade”.
B) Use a power cord that matches the voltage of the power outlet,
which has been approved and complies with the safety standard of your particular country.
C) Caution: This adapter Sinpro MPU101-105 is a forming part of
the medical device
Contact information:
Address: 5 Holland, Bldg. 201 Irvine, CA92618 U.S.A. TEL: (888)834-4577 E-Mail: sales@cybernetman.com
CyberMed H22/N22 User’s manual
xiii
Table of Contents
Acknowledgments .................................... iv
FCC Class B .............................................. v
Safety Instructions ................................... vi
Introduction ............................................ 1
Product Descripti on .................................... 1
Package list .............................................. 2
Features .................................................. 3
Specifications ........................................... 4
Guidance and manufacturer’s declaration –
electromagnetic emissions .......................... 6
Guidance and manufacturer’s declaration –
electromagnetic immunity........................... 8
Guidance and manufacturer’s declaration –
electromagnetic immunity........................... 9
Immunity ................................................. 9
Cleaning/Disinfecting ............................... 11
Getting Started ..................................... 12
System Set Up ........................................ 12
Dimension .............................................. 13
System View .......................................... 15
Disconnect Device ................................... 17
BIOS Setup ........................................... 18
Appendix ............................................... 28
A. Jumper settings and Connectors ............ 28
B. L type Stand (optional kit) .................... 51
C. Battery Pack Specifications.................... 52
D. Change Win Xp resolution to 1920*1080 . 53 E. How to disable battery when system hang up
-CyberMed H22/N22 ................................ 54
F. Scrap Computer Recycli n g ..................... 55
CyberMed H22/N22 User’s manual
1
Introduction
Product Description
The CyberMed H22/N22 Medical Pa nel PC are based on In tel 2nd generation Core i processor which can deliver faster gr aphic w it h
higher CPU performance. It a ccommod ates o ne 2.5” S ATA II hard disk drive and up to 8GB DDR3 SODIMM.
The high brightness LCD, Low noise (Cybe rMed H 22) / Fanless (CyberMed N22) solution, integrated multimedia functions and extensive expansion options make them the perfect platform upon which to build comprehensive lifestyle computing applications.
The CyberMed H22/N22 includes all the features of a powerful computer into a slim and attractive chassis. The CyberMed H22/N22 has a 21.5” high brightness TFT display with 1920 x 1080 resolutions.
The CyberMed H22/N22 is compact, Giga LAN and selectable WLAN network compatible PC with full safety and medical approval and features to control a dedicated system with a wide variety of applications. Combining the CyberMed H22/N22 into your system can achieve both cost-saving and efficient improvements.
Common applications include Surgical, Radiology, PACS (Picture Archiving Communication Systems), LIS (Lab Information Syste ms ) a nd Ele ctr o nic Med ica l R e cor d. T he CyberMed H22/N22 are definitely your perfect choices.
CyberMed H22/N2 2 User’s man ual
2
Package list
Before you begin installing your Medical Station, please make sure that the following items have been shipped:
The CyberMed H22/N22 Medical Panel PC unit
One CD containing user manual, chipset drivers
Power Adapter x 1 (Mf:Sinpro, type/model: MPU101-105)
Power cord – Hospita l grade used(US type), or other type in
UK, EU …etc.
Touch pen x 1 (By configuration)
Screw x 8 (VESA 75/100 use)
CyberMed H22/N22 User’s manual
3
Features
Seamless on the front side Easy wipe surfaces with no internal corners 21.5" (1920X1080) Diagnostic Panel High pe rf orma nce Intel 2nd generation Core i series mobile
CPU
Supports PCI-E x 16 & mini PCI-e expansion HDD Anti-vibration m echanism Low noise Smart fan solution(CyberMed H22) Fanless Solution (CyberMed N22) Anti-bacteria (MRSA) plastic housing Built-in Battery backup function (option) optional Video Graphic card (CyberMed H22 only)
CyberMed H22/N2 2 User’s man ual
4
Specifications
[
Hardware Sp ecifications
Display 21,5” 250 nits Full HD TFT LCD
CPU Support
CyberMed H22
Intel® socket r PGA 988B Cor e™ i 5-2410M (3M Cache, 2.30 G Hz) 35W Intel® socket r PGA 988 Cor e™ i 5-2510E ( 3M Cache, 2.50 G Hz) 35W Intel® socket r PGA 988 Cor e™ i 3-2330E ( 3M Cache, 2.20 G Hz) 35W Intel® socket PGA 988B Celeron™ B810 (2M Cache, 1.60 G Hz) 35W
CyberMed N22
Intel® Core™ i5-2467M Processor (3M Cache,
1.60 GHz)
Disk Driv e Space 2.5” Hard Di sk Driv e (SATA II )
Expansion
Two Mini P CIe slot;
One PCI expansion (load 10.78W) or one PCI-E
expansion slot
Button
Power Button// Audio adjustment (+)(-) //
brightness (+)(-
) // LCD on/off // Clean me(auto
release af ter 1 minute)
I/O
Standard versi on
1 RS-232 port + 1 RS-232/422/485 port 4 USB 2.0 ports 1 DC-in w/ lock function 2 Gigabit LAN RJ-45 Connectors Sound: 1 x Line-in 1 x line-out 2 x 1.5W Speakers on back side
LCD Specifi cat ions
Model Name
AUO M215HW03 V1
Display Type
21.5” col or TFT LCD
Max. Resoluti on
1920 x 1080 (Full HD)
Contrast Ratio
1000 : 1 (Typ)
Pixel Pitch (um)
248.25 (per one tri ad) × 248.25
Luminance (cd /m2)
250 (TYP)
CyberMed H22/N22 User’s manual
5
Viewing Angle
170°(H)
160°(V)
Operating Temperature
0°C~ 40°C (32°F~ 104° F)
Bright ness Control
Yes
Power Adapter Specifications
Power
Close-frame
MFR Sinpro
Type
MPU101-105
Input Volt age
AC 100 ~ 240 V, 1.25 – 0.5A @ 47 ~ 63 Hz
Output Voltage
DC 12V @ 8.33 A
MTBF
100,000 hrs operati on at 25°C
Mechani cal Speci f ications
Architecture Close-frame
Front Bezel
PET bezel with resistive touch screen
Color
Medical-white
Mounting / Holder VESA 75/100mm
Construction
3mm ABS + PC TYPE Plastic housing
Dimension (WxHx D) 540 x 375 x 78 mm Net Weight
CyberMed H22: 6.5kg (w/o power adapter) CyberMed N22: 7. 0kg ( w/o power adapter)
Packing Filler PE
Environmental Specifications
Temperature
Operating: 0°C to 40°C (32°F ~104°F)
Storage, Transportation: -20°C to 60°C (-4°F
~140°F)
Humidity
Operating: 10% to 90%, non-condensing
Storage, Transportation: 10% to 90%@ 40° C,
non-condensing
Vibration
Operating: 15g/0.53 oz, 11 ms, half sine wave
Non-operating: 50g/1.76 oz, 11 ms, half sine
wave
Shock
Operating: 5 ~ 17 Hz ,
Amplitude0.117 ~ 500Hz , Acceleration1.0G
Non-operating:10~55Hz/0.15g, 55~500Hz/2. 0g
CyberMed H22/N2 2 User’s man ual
6
Altitudes
Operational: up to 3000 m (9842 feet) Shippi ng: up t o 12192 m (40000 f eet)
Pressure
700 – 1060 hPa (Operation)
186 – 1060 hPa (Stor age)
186 – 1060 hPa (Transport ation)
Input Power Rating
For Adaptor :
AC100~240 V, 1.25 – 0. 5A, @47 ~ 63 Hz. For Unit:
DC 12V, 8.33A
Power Consumption
CyberMed H22: 98W Max (Typica l: 79.50W) CyberMed N22: 98W Max (Typica l: 46.50W)
Touch Screen
Type Full flat 5-wire, Analog Resistive
Interface
USB interface, 5V
Resolution 4096 x 4096
Light Transmission
>78% at 550 nm wavelength
Life Time
35M times, 250g at same place
Guidance and manuf act urer’s declaration – electromagnetic emissions
The model CyberMed H22/N22 is intended for use in the electromagnetic environment specified below. The customer or the user of the model
CyberMed H22/N22 should assure that it is used in such an environment.
Emissions t est Compliance Electromagn et ic environment –
guidance
RF emissions CISPR 11
The model CyberMed H22/N22 uses
RF energy only f or its i nternal function. Therefore, its RF emissions are very low and are not li kel y to cause any interference in nearby
electr onic equipment.
RF emissions CISPR 11
The model CyberMed H22/N22 is
suitable for use in all establishments, incl uding dom estic establishment s and those direct ly connected to the public l ow-v oltage power supply
Harmonic emissions
IEC 61000-3-2
CyberMed H22/N22 User’s manual
7
Voltage fluctuations/
flicke r emission s IEC 61000-3-3
network that supplies buildings used
for domesti c purposes.
Recommended sep arat io n dist ances between
portable and mobile RF communications equipment an d the model
CyberMed H22/N22
The model CyberMed H22/N22 is intended for use in an electromagnetic environment in which radiated RF di stur bance s are controlled. The customer or the user of the model CyberMed H22/N22 can help prev ent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communi cations equipment (transmit ters) and the model CyberMed H22/N22 as recom mended below, according to the maximum output power of the communications equipment.
Rated maximu m
output power of
transmitter
W
Separation di st ance according to
frequency of transmitter
m
150 kHz to
80 MHz
d = 1,2
80 MHz to
800 MHz
d = 1,2
800 MHz to
2,5 GHz
d = 2,3
0,01 0,12 0,12 0,23
0,1 0,38 0,38 0,73
1 1,2 1,2 2,3
10
3,8
3,8
7,3
100 12 12 23
For transmit ters rated at a maximum output power not listed above, the recomm ended separat ion distanced in meters (m) can be estimat ed using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmit ter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines m ay not apply i n all si tuations. Electromagnetic propagation is affected by absorption and refl ection from structures, objects and people.
CyberMed H22/N2 2 User’s man ual
8
Guidance and manuf act urer’s declaration – electromagnetic
immunity
The model CyberMed H22/N22 is intended for use in t he electromagnetic environment specified below . The customer or the user of the model CyberMed H22/N22 should assure that it is used in such an environment.
Immunity t est IEC 60601
test level
Compliance
level
Electromagnetic
environment –
guidance
Electrostatic discharge (ESD)
IEC 61000-4-2
±6 kV contact
±8 kV air
±6 kV contact
±8 kV air
Floors should be wood, concret e or ceramic tile. If floors are cover ed with synthetic material, the relative humidity should be at least 30 %.
Electrical fast transient/burst
IEC 61000-4-4
±2 kV for power
supply lines
±1 kV for input/output
lines
±2 kV for power
supply lines
±1 kV for input/output
lines
Mains power quality should be that of a typical commercial or hospital env ir onment.
Surge IEC 61000-4-5
±1 kV line(s) to line(s)
±2 kV line(s) to earth
±1 kV line(s) to line(s)
±2 kV line(s) to earth
Mains power quali ty should be that of a typical commercial or hospital env ir onment.
interruptions and voltage variations on power supply
input lines
IEC 61000-4-11
<5 % UT (>95 % dip in
UT) for 0,5 cycle
40 % UT (60 % dip in
UT) for 5 cycles
70 % UT
(30 % dip in
<5 % UT (>95 % dip in
UT) for 0,5 cycle
40 % UT (60 % dip in
UT) for 5 cycles
70 % UT
(30 % dip in
Mains power quality should be that of a typical commercial or hospital env ir onment. If the user of the model CyberM ed H22/N22 requires continued oper ation during power
mains interruptions, it is recommended that the model CyberMed
CyberMed H22/N22 User’s manual
9
UT)
for 25 cycles <5 % UT
(>95 % dip in UT)
for 5 sec
UT)
for 25 cycles <5 % UT
(>95 % dip in UT)
for 5 sec
H22/N22 be powered
from an uninterr uptible power supply or a battery.
Power frequency
(50/60 Hz) magnetic field
IEC 61000-4-8
3 A/m
3 A/m
Power frequency magnetic fields should be at lev els characteristic of a typical location in a typical commercial or hospital env ir onment.
NOTE UT is the a.c. mains volt age pri or to application of the test lev el.
Guidance and manufacturer’s declaration – electromagnetic immunity
The model CyberMed H22/N22 is intended for use in the electromagnetic environment specified below. The customer or the user of the model CyberMed H22/N22 should assure that it is used in such an environment.
Immunity
IEC
60601
test
level
Compliance
level
Electromagnetic environment – guidance
Conducted RF IEC 61000-4-6
Radiated RF IEC 61000-4-3
3 Vrms 150 kHz to 80 MHz
3 V/m
80 MHz to 2,5
GHz
Vrms
V/m
Portable and mobile RF communications equipment should be used no closer to any part of the model CyberMed H22/N22, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Recommended separation distance
d = 1,2
d = 1,2 80 MHz to 800 MHz d = 2,3 800 MHz to 2,5 GHz
where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).
Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey ,
a
should be less than the compliance level in each frequency range.
b
Interference may occur in the vicinity of equipment marked with the following symbol:
CyberMed H22/N2 2 User’s man ual
10
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones
and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the model CyberMed H22/N22 is used exceeds the applicable RF compliance level above, the model CyberMed H22/N22 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the model CyberMed H22/N22.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than V/m.
CyberMed H22/N22 User’s manual
11
Cleaning/Disinfecting
Steps:
1. Wipe the CyberMed H22/N22 with a dry clean cloth.
2. Prepare agent per manufacturer’s instructions or hospital protocol.
Cautions:
Do not immerse or rinse the CyberMed H22/N22 and i ts
peripherals. If you accidentally spill liquid on the device, disconnect the u nit fro m the pow er so ur ce. Con t a ct your Biomed regarding the continued safety of the unit before placing it back in operation.
Do not spray cleaning agent on the chassis. Do not use disinfectants that contain phenol. Do not autoclave or clean the CyberMed H22/N 22 or its
perip hera ls w ith s tron g aro mat ic, c hlor inate d, k eto ne, e ther , or Esther solvents, s harp too ls o r abra s ive s. Never imme rse electrical connectors in water or othe r liquids .
CyberMed H22/N2 2 User’s man ual
12
Getting S tarted
System Set Up
The follo wing is a s um mar y of the step s i n set ti n g up the system for us e. (1). Yo u ca n fix t he s ys tem to a mo unt ing fix tu re using t he screw
holes on the sides of the system.
(2). Make any requ ired exter nal co nnections suc h as t he di spla y,
keyboard, and LAN.
(3). Plug the appropriate end of the power cord int o the power
connector on the rear of the system and the plug to an electrical outlet.
(4).
Waiting for 3 seconds
(5). If nece ssa ry, ru n t he BIOS SE TUP programs to co nfigu re the
system.
the n press the power switch on the
fron t p a nel of the s y s tem o n ce to tur n on the s y s tem po w e r .
Caution:
In or der to b oot up system f rom USB-CD/DVD drive, please connect USB-CD/DVD drive, turn on computer power, keep on pressing “F11” key, go into BIOS quick boot menu, select “USB-CD ROM”, WAIT FOR 20
SECONDS, then press enter, system OS will boot up from USB -CD/DVD drive directly.
CyberMed H22/N22 User’s manual
13
Dimension
CyberMed H22
CyberMed H22/N2 2 User’s man ual
14
CyberMed N22
CyberMed H22/N22 User’s manual
15
System View
Front View
Hotkey and LED definition at front panel
Located on Touch screen bottom side, from left to right, front
view 1-1. Up. HDD: Yellow 1-2 Down. B attery:
AC mode: Dark Battery mode : Yellow Battery low: Yellow blinking
2. Power (with LED status indicator: ON: Green, OFF: dark)
3. Volume adjustment (-)
4. Volume adjustment (+)
5. Brightness (-)
6. Brightness (+)
7. LCD on/ off (wit h LED sta tus indica tor: LCD ON: dark, LCD OFF:
Webcam (optional)
CyberMed H22/N2 2 User’s man ual
16
Yellow)
8. Clean me (with LED status indicator: ON: Yellow, OFF: dark) a. Keep on contacting 5 second s to active b. keep contact ing 5 secon ds to release c. auto release after 60 seconds
I/O parts (CyberMed H 22/N22)
CyberMed H22/N22 User’s manual
17
Disconnect Device
Unplug the power cord from the power
adapter jack to disconnect the device.
CyberMed H22/N2 2 User’s man ual
18
BIOS Se t up
BIOS Introduction
The AMI BIOS (Basic Input / Output System) installed in your computer system’s ROM supports Intel processors. The BIOS provi des criti cal low-lev el s u pport fo r a st and ard d evi ce su ch as disk drives, serial ports and parallel ports. It also adds virus and password protection as well as special support for detailed fine-tuning of the chipset controlling the entire system.
BIOS Setup
The AMI BIOS provides a Setup utility program for specifying the syste m c o nfig ura tio ns and s etti ngs. T he B IOS RO M o f the sys te m stores t he Set up uti lity . Whe n yo u tur n o n t he co mpu ter, t he AMI BIOS is immediately activated. Pressing the <Del> key immediately allows you to enter the Setup utility. If you are a little bit late pr es s ing the < D e l> key, POST (P o wer On Sel f Te s t) will continue with its test routines, thus preventing you from invoking the Setup. If you still wish to enter Setup, restart the system by pressing the ”Reset” button or simultaneously pressing the <Ctrl>, <Alt> and <Delete> keys. You can also restart by turning the system Off and back On again. The following messa g e will appear on the screen:
Press <DEL> to Enter Setup
In general, you press the arrow keys to highlig ht i tems, <Enter> to select, the <PgUp> and <P gDn> keys to cha nge entries, <F1> for help and <Esc> to quit.
When you enter the Setup utility, the Main Menu screen will appear on the screen . The Main Menu all ows you to sele ct from various setup functions and exit choi ces.
CyberMed H22/N22 User’s manual
19
Main
This section provides inf orm at ion on t he BI OS inf orm ation, M em ory inform at i on, and LAN MAC inf orm ation
System Language Choose the BIOS defa ul t la nguage .
System Date/Time Set the system date/ time. Use t he <Tab> k ey to switch between data/time elements.
CyberMed H22/N2 2 User’s man ual
20
Advanced
Launch OpROM Suppo rt Launch PXE OpROM
Enables or disabl es Boot Option for Legacy Network Devices.
Launch St orag e OpR OM
Enables or disabl es Boot Option for Legacy Mass Storage Devices with Option ROM
.
PCI Subsyst em Settings
PCI ROM Priority
In Case of multiple Option ROMs (Legacy and EFI Compatible), specifies what PCI Option ROM to launch.
PCI Latency Timer
Value to be programmed into PCI Latency Timer Register.
VGA Palet t e Snoop
Enables or disabl es VGA Palette Registers Snooping.
PERR# Generation
Enables or Disables PCI Device to Generate PERR#.
SERR# Generatio n
Enables or Disables PCI Device to Generate SERR#.
Relaxed O rd ering
Enables or Disables PCI Express Device Relaxed Ordering.
Extended Tag
If ENABLED allows Device to use 8-bit Tag field as a requester.
CyberMed H22/N22 User’s manual
21
No Snoop
Enables or Disable s PCI Express Device No Snoop option.
Maximum Payload
Set M ax im um P ay lo ad o f PC I Exp r ess De vic e o r a llow Sy ste m BIOS to se le c t the va lu e
Maximum Read Request
Set Maximum Read Request Size of PCI Express Device or allow Sy s te m BIOS to select the va lue .
ASPM Support
Set the ASPM Level: Force L0 – Force all links to L0 State : AUTO – BIOS auto configure : DISABLE – Disa b les ASPM.
Extended Sy nch
If ENABLED allows generation of Extended Synchronization patterns.
ACPI Setting s
Enables ACPI Auto Conf
Enables or Disables BIOS ACPI Auto Configuration.
Enable Hibernation
Enab les o r Dis able s Sy stem abi lity to Hib erna te ( OS/S 4 Sle ep State). This option may be not effective with some OS.
ACPI Sleep State
Select the highest ACPI sleep state the system will enter, when the SUSPEND button is pressed.
S5 RTC Wake Settings
Wake System with Fixed Time
Enables or disabl es system wake on alarm event. When enabled, the system will wake on the time specified.
Wake system with Dynamic Time
Enables or disabl es system wake on alarm event. When enabled, the system will wake on the current time+Increase minute(s).
CPU Configuration
Hyper-Threading
Enabled for Windows XP and Linux (OS optimized for Hyper-Threa ding Tech no logy) a nd Disabled for othe r OS (OS optim iz e d for Hyper-Threading Technology)
Core-Multi Processing
Enable or Disable Core-Multi Processing mode.
Execute Disable Bi t
XD can prevent certain classes of malicious buffer overflow att a ck s when combined with a suppor ting OS (Windows
CyberMed H22/N2 2 User’s man ual
22
Server 2003 SP1, Windows XP SP2, SuSE Linux 9.2, RedH at Enterprise 3 Update 3.)
Limit CPUID Maximum
Disab led for Windows XP.
IDE Configurat ion
ATA or IDE Configuration
Select ATA or IDE configuration.
Configure SATA AS
Sel ect a configuration for SATA controller.
HDD Acoust i c Power Ma
Option to enable or disable HDD Acoustic Power Management.
DiPM
Option to enable or disable DiPM
Intel IGD SWSCI OpRegion
DVMT Mod e Select
Selects DVMT Mode used by Internal Graphics Devi ce.
DVMT/FIX ED Memo ry
Selects DVMT/FIXED Mode Memory size used by Internal Gr aphics Device .
IGD – Boot Type
Sele ct the V id e o D e v ic e which will b e a ctiva te d during PO ST . This has no effect if external graphics presen t.
LCD Panel Ty pe
Select LCD panel used by Internal Graphics Device by selecting the appropriate setup item.
Panel Scaling
Select the LCD panel scaling option used by th e Internal Gr aphics Device .
GMCH BLC Control
Back Ligh t Control Setting
BIA Control Spread Spectrum clock
>>Hardware: Spread is controlled by chip; >>Software: Sprea d is controll ed by BIOS.
TV1 Standard TV2 Standard Active LFP
Select the Active LFP Configuration. No LVDS:VBIOS does not enable LVDS. INT-LVDS:VBIOS enables LVDS driver by Integrated encoder.
CyberMed H22/N22 User’s manual
23
SDV0 LVDS:VBIOS enables LVDS driver by SDV0.
USB Con fi guration
Legacy USB Support
Allows USB devic es to b e used in MS-DOS.
EHCI Hand-off
This is a w orkar ound for 0 Ses w itho ut EHC I ha nd-off support. The EHCI ownership change should be claimed by EHCI driver.
USB transfer time-out
The time-out va lue for C on tro l, Bulk , and I nter ru pt tra nsf er s.
Device reset time-out
USB mass storage device Start Un it command time -out.
Device power-up delay
Maxim um ti me the dev ice will tak e before it properly reports itself to the HOST Controller. ‘Auto’ uses default value: for a Root port it is 100 ms, for a Hub port the delay is taken from Hub descriptor.
F71869 Super IO Configura t i on
Serial Port 0 Config ura t i on
Set Parameters of Serial Port 0 (COM A).
Serial Port 1 Config ura t i on
Set Para meters of Se rial Port 1 (COM B).
F71869 H/W Monitor
Monito r hard w a re s tatus
Second Sup er IO C onfigur a t i on
Serial Port 1 Configuration
Set Parameters of Serial Por t 1 (COM C).
Serial Port 2 Config ura t i on
Set Para meters of Se rial Port 2 (COM D) .
Serial Port 3 Config ura t i on
Set Para meters of Se rial Port 3 (COM E) .
Serial Port 4 Config ura t i on
Set Para meters of Se rial Port 4 (COM F).
Serial Port Console Red irection
Serial Port Console Redirection.
CyberMed H22/N2 2 User’s man ual
24
Chipset
Host Bridge/South Bridge
This screen provides information on Host Bridge/South Bridge parameters.
CyberMed H22/N22 User’s manual
25
Boot
Setup Prompt Timeout
Number of seconds to wait for setup activation key. 65535(0xFFFF) means indefinite waiting.
Bootup Numlock State
Selects the ke ybo ar d NumL o ck sta te.
Full Screen LOGO Show
Allows you to determine whether to display the AMI Logo at system startup. Disabled displays normal POST mess age.
Fast Boot
Enables or disables the quick boot function to speed up the system boot-up process to shorten the waiting time for entering the op erat ing sy ste m a nd to deliver gre a ter e fficienc y for daily use.
GateA20 Activ e
This optio n is use ful wh en any R T code is executed above 1MB . Upon Request GA20 can be disabled using BIOS services. (Default) Always Do not allow disabling GA20.
Option ROM Messages
Sets display made for op tion ROM.
Interrupt 19 Captu re
Enables or disabl es Option ROMs to Trap Int 19.
Boot Option Priorities
Specifies the sequence of loadi ng the opera ting system from the installed hard drives.
CyberMed H22/N2 2 User’s man ual
26
Security
Enab les or d isab les the sec urit y chip . It is rec omm ended that you use this function with the Admin istrator/User password.
CyberMed H22/N22 User’s manual
27
Save & Exit
Save Change s and Exit
Exit system setup after saving the changes. Discard Cha nges and Exi t Exit system setup without saving any changes. Save Change s and Reset Reset the system after saving the changes. Discard Cha nges and Reset Reset system setup withou t s a vi ng t he changes. Save Change s Save the changes done so far to any of setup options. Discard Cha nges Discard the changes done so far to any of setup options. Restore D efaults Restore/load default values for all the setup options. Save as User Defaults Save the changes done so far as User Defaults. Restore User Default s Restore the User Defaults to all the setup options. EFIGUI_FLASH Press <Enter> to execute the simple EFI GUI Flash Program.
APPENDIX
CyberMed H22/N2 2 User’s man ual
28
Appendix
A. Jumper se ttings and Connectors
This appendix gives the definitions and shows the positions of jumpe rs , he a ders and connectors . All of the configuration jumpers on CyberMed H22/N22 are in the pr op er position.
Note: Som e of jum pers or connectors wi l l b e rem ov ed base on syst em configuration.
Jumper and Connector Definition Block
APPENDIX
CyberMed H22/N22 User’s manual
29
Description
Jumper Setting
analog Inverter
1-2 (default)
PWM Inverter
2-3
Description
Jumper Setting
4 wire
1-2, 3-4, 5-6, 7 -8, 9-10
5 wire
3-4, 5-6, 7-8, 9 -10 (default)
8 wire
1-2
Description
Jumper Setting
3M type
1-2, 3-4 (default)
ELO type
5-6,7-8
Description
Jumper Setting
+5VS (for 17"/19"/21.5”)
1-2,3-4 (default)
+3.3VS (for 10"/12"/15")
5-6,7-8
Description
Jumper Setting
Clear ME RTC register s
1-2
Keep ME RTC registers
OPEN (default)
APPENDIX
CyberMed H22/N2 2 User’s man ual
30
Description
Jumper Setting
Normal Open
1-2 (default)
CMOS Clear
2-3
JP11 – Thermal sensor
Description
Jumper Setting
Auto detect
1-2(default)
always 25 2-3
always -40 ℃
NC
Description
Jumper Setting
SATA DOM
1-2 ---power +5V
SATA
2-3(default)--- GND
Description
Jumper Setting
RS-232
5-6, 9-11, 10-12, 15-17, 16-18(default)
RS-422
3-4, 7-9, 8-10, 13-15, 14-16, 21-22
RS-485
1-2, 7-9, 8-10, 19-20
APPENDIX
CyberMed H22/N22 User’s manual
31
Connector Definition
1
4
Pin #
Signal Description
1
+12V
2
Ground
3
Ground
4
+5V
1
4
Pin #
Signal Description
1
+12V
2
Ground
3
Ground
4
+5V
Pin1
Pin #
Signal Description
1
BATT+
APPENDIX
CyberMed H22/N2 2 User’s man ual
32
2
BATT+
3
BATT+
4
BAT_T
5
BAT_C
6
BAT_D
7
BATT_EN#
8
BATT-
9
BATT-
10 BATT-
1 5
Pin #
Signal Description
1
DC In
2
DC In
3
Ground
4
Ground
5
Ground
J5,J6,J7 – Internal USB +3.3V Interface
Pin #
Signal Description
1
+3.3VS
2
Data -
3
Dat a +
4
Ground
5
Ground
APPENDIX
CyberMed H22/N22 User’s manual
33
6 1
Pin #
Signal Description
1
+12V
2
+12V
3
Backlight Adjust
4
Backligh t Enable
5
Ground
6
Ground
1
9
Pin #
Signal Description
8-wire
4-wire
5-wire
1
UL(X+)
UL(X+)
UL(X+)
2
UR(Y+)
UR(Y+)
UR(Y+)
3
N/A
N/A
PRCBE
4
LR(X-)
LR(X-)
LR(X-)
5
LL(Y-)
LL(Y-)
LL(Y-)
6
X+_DRIVE
N/A
N/A
7
Y+_DRIVE
N/A
N/A
8
X-_DRIVE
N/A
N/A
9
Y-_DRIVE
N/A
N/A
APPENDIX
CyberMed H22/N2 2 User’s man ual
34
Pin #
Signal Description
J10(SYSTEM)
J11(CPU) 2.54mm
J12(CPU) 2.0mm
1
AUX PWM
CPU PWM
SYS PWM
2
AUX RPM
CPU RPM
SYS RPM
3
VAUXFAN
VCPUXFAN
VSYSXFAN
4
GND
GND
GND
Pin #
Signal Description
1
+3.3V_TP
2
C2CK
3
C2D
4
Ground
APPENDIX
CyberMed H22/N22 User’s manual
35
Pin #
Signal Description
1
+5VSB
2
+5VSB
3
Data -
4
Dat a +
5
Ground
6
Ground
Pin #
Signal Description
1
+5VSB
2
+5VSB
3
Data -
4
Dat a +
5
Ground
6
Ground
Pin # Signal Description Pin # Signal Description
1
WAKE#
2
+3.3VSB
3
Reserved
4
GND
5 Reserved 6 +1.5VS
7
CLKREQ#
8
Reserved
9
GND
10
Reserved
11
REFCLK-
12
Reserved
APPENDIX
CyberMed H22/N2 2 User’s man ual
36
Pin #
Signal Description
1
RTC +3. 3V
2
GND
13
REFCLK+
14
Reserved
15
GND
16
Reserved
17
Reserved
18
GND
19
Reserved
20
Reserved
21
GND
22
PERST#
23
PERn0
24
+3.3VSB
25 PERp0 26 GND
27
GND
28
+1.5VS
29
GND
30
SMB_CLK
31
PETn0
32
SMB_DATA
33
PETp0
34
GND
35
GND
36
USB_D-
37
GND
38
USB_D+
39
+3.3VSB
40
GND
41
+3.3VSB
42
Reserved
43
GND
44
Reserved
45 CL_CLK 46 Reserved
47
CL_ DATA
48
+1.5VS
49
Controller Link RST#
50
GND
51 Reserved 52 +3.3VSB
APPENDIX
CyberMed H22/N22 User’s manual
37
Pin
#
Side B
Side A
Pin
#
Side B
Side A
1
+12V
PRSNT1#
42
PETn6
GND
2
+12V
+12V
43
GND
PERp6
3
+12V
+12V
44
GND
PERn6
4
GND
GND
45
PETp7
GND
5
SMCLK
PCIE_TXN6
46
PETn7
GND
6
SMDAT
PCIE_TXP6
47
GND
PERp7
7
GND
PCIE_RXN6
48
Reserved
PERn7
8
+3.3V
PCIE_RXP6
49
GND
GND
9
Reserved
+3.3V
50
PETp8
Reserved
10
+3.3V
+3.3V
51
PETn8
GND
11
WAKE#
PERST#
52
GND
PERp8
12
Reserved
GND
53
GND
PERn8
13
GND
PCIEx16_CLK+
54
PETp9
GND
14
PETp0
PCIEx16_CLK-
55
PETn9
GND
15
PETn0
GND
56
GND
PERp9
16
GND
PERp0
57
GND
PERn9
17
Reserved
PERn0
58
PETp10
GND
18
GND
GND
59
PETn10
GND
19
PETp1
Reserved
60
GND
PERp10
20
PETn1
GND
61
GND
PERn10
21
GND
PERp1
62
PETp11
GND
22
GND
PERn1
63
PETn11
GND
23
PETp2
GND
64
GND
PERp11
24
PETn2
GND
65
GND
PERn11
25
GND
PERp2
66
PETp12
GND
26
GND
PERn2
67
PETn12
GND
27
PETp3
GND
68
GND
PERp12
28
PETn3
GND
69
GND
PERn12
29
GND
PERp3
70
PETp13
GND
30
PCIEx1_CLK+
PERn3
71
PETn13
GND
31
PCIEx1_CLK-
GND
72
GND
PERp13
APPENDIX
CyberMed H22/N2 2 User’s man ual
38
32
GND
Reserved
73
GND
PERn13
33
PETp4
Reserved
74
PETp14
GND
34
PETn4
GND
75
PETn14
GND
35
GND
PERp4
76
GND
PERp14
36
GND
PERn4
77
GND
PERn14
37
PETp5
GND
78
PETp15
GND
38
PETn5
GND
79
PETn15
GND
39
GND
PERp5
80
GND
PERp15
40
GND
PERn5
81
Reserved
PERn15
41
PETp6
GND
82
PCICLK_33M
GND
Pin #
Signal Description
Pin #
Signal Description
1
+LCD (+5V/ +3.3V)
2
+LCD (+5V/ +3.3V)
3
+LCD (+5V/ +3.3V)
4
+LCD (+5V/ +3.3V)
5
Ground
6
Ground
7
Ground
8
Ground
9
A_RxIn0-
10
B_RxIn0-
11
A_RxIn0+
12
B_RxIn0+
13
Ground
14
Ground
15
A_RxIn1-
16
B_RxIn1-
17
A_RxIn1+
18
B_RxIn1+
19
Ground
20
Ground
21
A_RxIn2-
22
B_RxIn2-
23
A_RxIn2+
24
B_RxIn2+
25
Ground
26
Ground
27
A_CKIN-
28
B_CKIN-
29
A_CKIN+
30
B_CKIN+
31
Ground
32
Ground
33
A_RxIn3-
34
B_RxIn3-
35
A_RxIn3+
36
B_RxIn3+
37
Ground
38
Ground
39
Ground
40
Ground
APPENDIX
CyberMed H22/N22 User’s manual
39
J23 H9.2 Near CPU J24 H5.2 Near External
Pin
Symbol
Pin
Symbo
l
Pin
Symbol
Pin
Symbol
Pin
Symbol
Pin
Symbol
1
VREFDQ
69
DQ27
137
DQS4
2
VSS
70
DQ31
138
VSS
3
VSS
71
VSS
139
VSS
4
DQ4
72
VSS
140
DQ38
5
DQ0
73
CKE0
141
DQ34
6
DQ5
74
NC
142
DQ39
7
DQ1
75
VDD
143
DQ35
8
VSS
76
VDD
144
VSS
9
VSS
77
NC
145
VSS
10
DQS0#
78
NC
146
DQ44
11
DM0
79
BA2
147
DQ40
12
DQS0
80
NF/A14
148
DQ45
13
VSS
81
VDD
149
DQ41
14
VSS
82
VDD
150
VSS
15
DQ2
83
A12
151
VSS
16
DQ6
84
A11
152
DQS5#
17
DQ3
85
A9
153
DM5
18
DQ7
86
A7
154
DQS5
19
VSS
87
VDD
155
VSS
20
VSS
88
VDD
156
VSS
21
DQ8
89
A8
157
DQ42
22
DQ12
90
A6
158
DQ46
23 DQ9 91 A5 159 DQ43 24 DQ13 92 A4 160 DQ47
25
VSS
93
VDD
161
VSS
26
VSS
94
VDD
162
VSS
27
DQS1#
95
A3
163
DQ48
28
DM1
96
A2
164
DQ52
29
DQS1
97
A1
165
DQ49
30
RESET#
98
A0
166
DQ53
31
VSS
99
VDD
167
VSS
32
VSS
100
VDD
168
VSS
33
DQ10
101
CK0
169
DQS6#
34
DQ14
102
CK1
170
DM6
35
DQ11
103
CK0#
171
DQS6
36
DQ15
104
CK1#
172
VSS
37
VSS
105
VDD
173
VSS
38
VSS
106
VDD
174
DQ54
39
DQ16
107
A10
175
DQ50
40
DQ20
108
BA1
176
DQ55
41
DQ17
109
BA0
177
DQ51
42
DQ21
110
RAS#
178
VSS
43 VSS 111 VDD 179 VSS 44 VSS 112 VDD 180 DQ60
45
DQS2#
113
WE#
181
DQ56
46
DM2
114
S0#
182
DQ61
47
DQS2
115
CAS#
183
DQ57
48
VSS
116
ODT0
184
VSS
49 VSS 117 VDD 185 VSS 50 DQ22 118 VDD 186 DQS7#
51
DQ18
119
A13
187
DM7
52
DQ23
120
NC
188
DQS7
53
DQ19
121
NC
189
VSS
54
VSS
122
NC
190
VSS
55
VSS
123
VDD
191
DQ58
56
DQ28
124
VDD
192
DQ62
57
DQ24
125
NC
193
DQ59
58
DQ29
126
VREFCA
194
DQ63
59
DQ25
127
VSS
195
VSS
60
VSS
128
VSS
196
VSS
61
VSS
129
DQ32
197
SA0
62
DQ3#
130
DQ36
198
EVENT#
63
DM3
131
DQ33
199
VDDSPD
64
DQ3
132
DQ37
200
SDA
65
VSS
133
VSS
201
SA1
66
VSS
134
VSS
202
SCL
67
DQ26
135
DQS4#
203
VTT
68
DQ30
136
DM4
204
VTT
APPENDIX
CyberMed H22/N2 2 User’s man ual
40
H22/N22)
Pin #
Signal Description
1
+3.3V
2
+3.3V
3
KP_SCL
4
KP_SDA
5
HEATER_LED#
6
KP_INT#
7
SATA_LED#
8
Ground
9
Ground
Pin #
Signal Description
1
+5V
2
P80_DAT
3
P80_CLK
4
Ground
1
9
APPENDIX
CyberMed H22/N22 User’s manual
41
Pin #
Signal Description
Pin #
Signal Description
1
EC_TRST#
2
+3.3V
3
EC_TMS
4
EC_RDY#
5
EC_TDI
6
GND
7
EC_TCK
8
GND
9
EC_TDO
10
GND
Pin #
Signal Description
Pin #
Signal Description
1
LPC AD0
2
PCI reset
3
LPC AD1
4
SERIRQ
5
LPC AD2
6
+3.3V
7
LPC AD3
8
+5V
9
LPC Frame
10
PCI CLKRUN
11
Debug CLK
12
SMB CLK
13
GND
14
SMB DATA
15
SUS_STAT#
16
+3.3V
APPENDIX
CyberMed H22/N2 2 User’s man ual
42
Pin #
Signal Description
1
Power Butt on
2
+3.3V
3
Sound Volume Up
4
Sound V olume Down
5
Ground
6
LCD BackL ight Up
7
LCD BackL ight Down
8
Touch Screen Forbid
9
LCD BackLight ON/ OFF
Pin #
Signal Description
1
Keyboard data
2
Mouse data
3
GND
4
5V 5 Keyboard c lock
1
9
APPENDIX
CyberMed H22/N22 User’s manual
43 6 Mouse clock
Pin #
Signal Description
1
Light Sensor
2
NC
3
+3.3V
Pin #
Signal Description
1
VCC_POR#
2
GND
Pin #
Signal Description
1
+3.3V_UC
2
HEATER_LED#
3
KEYLOCK_LED#
APPENDIX
CyberMed H22/N2 2 User’s man ual
44
Pin #
Signal Description
1
Ground
2
Tx+
3
Tx-
4
Ground
5
Rx-
6
Rx+
7
Ground
Pin #
Signal Description
Pin #
Signal Description
1
DCD#
2
DSR#
3
SIN
4
RTS#
5
SOUT
6
CTS#
7
DTR#
8
RI#
9
GND
10
+5VS
Pin #
Signal Description
Pin #
Signal Description
1
232_DCD
2
232_DSR
APPENDIX
CyberMed H22/N22 User’s manual
45 3 232_SIN
4
232_RTS
5
232_SOUT
6
232_CTS
7
232_DTR
8
232_RI
9
GND
10
+5VS
Pin1
Pin #
Signal Description
Pin #
Signal Description
1
CS#
5
VDD
2
SO 6 HOLD#
3
WP#
7
SCK
4
VSS
8
SI
Pin #
Signal Description
1
SATA LED
2
+3.3V
3
+3.3V
4
Power LED
APPENDIX
CyberMed H22/N2 2 User’s man ual
46
Pin #
Signal Description
1
+12V
2
+12V
3
Ground
4
Ground
J43(Righ t Channe l )
J45(Left Channel)
Pin #
Signal Description
Pin #
Signal Description
1
AMP. Out +
1
AMP. Out +
2
AMP. Out -
2
AMP Out -
Pin #
Signal Description
1
HOOK_ON#
2
Handset speaker
3
Handset MIC
4
GND
APPENDIX
CyberMed H22/N22 User’s manual
47
Pin #
Signal Description
1
Power ON
2
GND
Pin #
Signal Description
1
Data0+
2
Data0-
3
Data1+
4
Data2+
5
Data2-
6
Data1-
7
Data3+
8
Data3-
APPENDIX
CyberMed H22/N2 2 User’s man ual
48
Pin #
Signal Description
1
+5V
2
Data-
3
Data+
4
GND
Pin #
Signal Description
Pin #
Signal Description
1
TMDS Data2-
2
TMDS Data2+
3
TMDS Data2 shiel d
4
NC
5
NC
6
DDC Clock
7
DDC Data
8
Analog VSYNC
9
TMDS Data1-
10
TMDS Data1+
11
TMDS Data1 Shiel d
12
NC
13
NC
14
+5V
15
GND
16
Hot Plug Det ect
17
TMDS Data0-
18
TMDS Data0+
19
TMDS Data0 Shiel d
20
NC
21
NC
22
TMDS Clock Shield
23
TMDS Clock+
24
TMDS Clock-
C1
Analog Red
C2
Analog Green
C3
Analog Blue
C4
Analog HSYNC
C5
GND
C6
GND
Pin #
Signal Description
J53
Mic rophone (stereo) P ink
J54
Lin e O ut ( st ereo) Green
APPENDIX
CyberMed H22/N22 User’s manual
49
Pin #
Signal Description
1
SYS_RESET#
2
GND
Pin #
Signal Description
1
SYS_RESET#
2
GND
Pin #
Signal Description
RS-232
RS-422
RS-485
1
Carrier Detect
Transmit Data -
Transmit Data -
2
Recei ve Data
Transmit Data +
Transmit Dat a +
APPENDIX
CyberMed H22/N2 2 User’s man ual
50 3 Transmit Data
Receive Data +
NC
4
Data Terminal Ready
Recei ve Data -
NC
5
Ground
NC
NC
6
Dat a Set Ready
NC
NC
7
Request to Send
NC
NC
8
Clear to Send
NC
NC
9
Ring Indicat or
NC
NC
Pin #
Signal Description
Pin #
Signal Description
1
232_DCD
2
232_SIN
3
232_SOUT
4
232_DTR
5
GND
6
232_DSR
7
232_RTS
8
232_CTS
9
232_RI
10
Not Us ed
APPENDIX
CyberMed H22/N22 User’s manual
51
B. L type Stand (optional kit)
White color require by most of the application.
Key Features and Benefits
10 degree tilt down and 3 0 d e g re e tilt up so lutio n 5,000 times hinge life cycle
Weight Capacity:
Specifications:
Max 10kgs Monitor Mounting Holes VESA 75*75mm or 10 0*100m m Appl ication using Desktop sta nd
APPENDIX
CyberMed H22/N2 2 User’s man ual
52
C. Battery Pack Specifications (optional kit)
Batte ry Model133 BP-WMP001-22/1900A Battery Type Li-ion 2S2P
Minimum Capacity
3800 mA h
Nominal Voltage
7.3 V
Max. Charge Voltage 8.4V
Cut Off Voltage
6.0v
Suggested Charge Current (Max.)
2A
System Continuous
Discharging Current
(Max.)
16.6 A
The End of Charge
Condition
150 mA/min
Discharge Protection
UVP/OCP
Charge Protection OVP/OTP
Self-dischar ge Rate
10uA ~800 uA
Dimensions
133 x 47 x 21mm
Weight 220g+/-20g Ambient Temperature 0°C ~ +45°C
Storage Temperat ure
-20°C ~ +60°C
Energy
27.74Wh
Backup
100 W/ 10 min
APPENDIX
CyberMed H22/N22 User’s manual
53
D. Change Win Xp resol ution to 1920*1080
1. Please help to follow below step to change setting
2. In display properties settings advanced monitor
disable hide mode …screen resolution will have 1920*1080 resolution can use.
APPENDIX
CyberMed H22/N2 2 User’s man ual
54
E. How to disable battery when system hang up –CyberMed H22/N22
1. When system hang up ,press pow er butto n 4 seconds to t ur n
off system . If you can’t power on system by power button. Pleas e f o l low belo w s tep to reset system .
2. Remove AC power cord, then the battery LED will on.
3. Press vo lume up ke y 10 seconds, then a ll LED will t urn on and
turn off
4. Plug in AC power cord again, press power button then you can
power on system.
APPENDIX
CyberMed H22/N22 User’s manual
55
F. Scrap Computer Recycling
Cybernet e-recycling SOP
Cybernet has an e-recycling program that is very easy to use. J ust follow the steps expla i ned be low or go to our website at www.cybernetman.com.
1. Request an RMA via phone, email or support request.
2. We will arrange a call tag to have the product picked up. Just have it packed and ready to ship.
We do the rest !