CyberData 011113 Installation Quick Reference

Installation Quick Reference
VoIP Indoor Intercom with Keypad
SiP Compliant
Quick Reference 930225G © 2011, CyberData Corpora tion, ALL RIGHTS RESERVED© 2011, CyberDa ta Corporation, ALL RIGH TS RESERVED 930225G Quick Reference
011113*, RAL 9003, Signal White
*Replaces the 011078 number.
The IP Endpoint Company
Contacting CyberData
611469B
Single Gang or 2 Gang Box
Can Be Rotated
to Mount on Either Sides
(Not Provided)
Drywall or Wall Cutout
(4 Pieces)
Machine Screw
Mounting Screw
for Gang Box
(4 Pieces)
Warranty
CyberData warrants its product agains t defects in material or workmanship for a period of two years from the dat e of purchase. Should the product fail within the warranty period, CyberData will repair or replace the product free of charge. This warranty includes all pa rts and labor.
Should the product fail out-of-warranty, a flat rate repair charge of one half of the purchase price of the product wil l be assessed. Repairs that are in warranty but are damaged by improp er modifications or abuse, will be charged at the out-of-warranty rate. Products shipped to CyberData, both in and out-of-warranty, are shipped at the expense of the customer. Shipping charges for repaired products shipped back to the customer by CyberData, will be paid by CyberData.
CyberData shall not under any circu mstances be liable to any person for any special, incidental, indirect or consequential damages, including without limitation, damages resulting fr om use or malfunction of the products, loss of profits or revenues or costs of replacement goods, even if CyberData is informed in advance of the possibility of such damages.
For product service, contact the Returned Materials Authorization (RMA) department. A product will not be accepted for return without an approved RMA number. Send the product, in its o riginal package, to: CyberData Cor­poration, 2555 Garden Road, Monter ey, CA 93940, Attention: RMA “your RMA number”
The most recent warranty information i s available at: Web: http://www.cyberdata.net/support/warranty/index.html
Corporate Headquarters
CyberData Corporation 3 Justin Court Monterey, CA 93940, USA
Phone: 831-373-2601 Fax: 831-373-4193 www.CyberData.net
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333 Web: http://www.cyberdata.net/support/contactsupportvoip.html
RMA Dept: (831) 373-2601 ext. 136 Email: RMA@CyberData.net RMA Status: http://www.cyberdata.net/support/rmastatus.html
Typical System Installation
Getting Started
• Download the VoIP Indoor Intercom with Keypad Operations Guide PDF file from the Documents page at:
http://www.cyberdata.net/products/voip/digitalanalog/in tercomkeypad/docs.html
• Create a plan for the locations of your Intercoms.
• Prior to installation, consult local building and electrical code requirements.
• WARNING: This enclosure is not rated for any AC voltages
!
Intercom Parts
Parameter Factory Default Setting
IP Addressing DHCP
IP Address
a
10.10.10.10
Web Access Username admin
Web Access Password admin
Subnet Mask
a
255.0.0.0
Default Gateway
a
10.0.0.1
a. Default if there is not a DHCP server present.
Door Strike
VoIP Intercoms with Keypad
IP Phone
IP PBX Server
Generic PoE Switch
123 456
(1) Intercom Assembly
(4)#6 x 0.75-inch Sheet Metal Screw
(1) Wall Mounting Kit
(4) #6 Plastic anchor (4) #6 x 3/8-inch Pan Head
Phillips Machine Screw*
(1) Gang Box Mounting Kit
* Only two screws are needed for a single gang box.
The CyberData SIP-enabled VoIP Indoor Intercom with Keypad is a Power-over-Ethernet (PoE 802.3af) and Voice-over-IP (VoIP) two-way communications device that easily connects into existing local area networks (LANs) with a single cable connection.
© 2011, CyberD ata Corporation, ALL RIG HTS RESERVED 930225G Quick Reference Quick Referenc e 930225G © 2011, Cyb erData Corporation, ALL RIGHTS RESERVED
RTFM Switch
Wall Mounting Options
RTFM
When the device is operational and linked to a network, you can use the Reset Test Function Management (RTFM) switch (see picture) to announce the device’s IP address or restore the device to the factory default settings.
To announce the device’s current IP address:
• Press and release the RTFM switch within a five second window.
Note The device will use DHCP to obtain the
new IP address (DHCP-assigned address or default to 10.10.10.10 if a DHCP server is not present).
To restore the device to factory default settings:
• Press and hold the RTFM switch for longer than five seconds.
Backplate
Can Be Rotated
Machine Screw
(4 Pieces)
to Mount on Either Sides
(4 Places)
Pre-Drilled Hole
Hole in Wall
(for Network Cable)
Plastic Anchor (4 Pieces Each)
Sheet Metal Screw &
Dimensions
Terminal Block Connections
6.5 [165]
DIMENSIONS ARE IN INCHES [MILLIMETER]
4.5 [115]
1.6 [40]
Alternate Power Input: 1 = +12 to +24 VDC at 500 mA 2 = Power Ground
Relay Contact: (2A at 30 VDC or 0.4A at 125 VAC
3 = Normally Open Common 4 = Normally Open Contact 5 = Door Sense Input 6 = Door Sense Ground Reference
J3
Terminal Block
Wire in,
3
4
up to 16 AWG
accept wire range
for continuous loads)
123456
Relay Contact: (1A at 30 VDC for continuous loads) 3 = Normally Open Common 4 = Normally Open Contact 5 = Door Sense Input 6 = Door Sense Ground Reference
2 = Power Ground
1 = +12 to +24 VDC at 1000mA (500mA minimum)
34
Alternate Power Input:
Wire in, accepts 16 AWG gauge wire
Loading...