Cutler Hammer, Div of Eaton Corp XT IEC Power Control Accessories Catalog

1.1
XTMCXF_
54
53
61
62
515261
62
71
72
82
81
536171
81
82
72
62
54
54
53
61
62
717283
84
54
53 61
627374
83
84
54
63 73
64
74
53
83
84
58
57
65
66
717283
84
Accessories
1
1
1
1
1
1
1
1
IEC Contactors and Starters
XT IEC Power Control
Front-Mount Auxiliary Contacts for Use with XTRM Mini Control Relays
Rated Operational Current AC-15 I
(A)
Conventional Thermal Current,
Open (A)
I
th
10 4 2 1.5 2NC 5 XTMCXFA02
10 4 2 1.5 1NO-1NC 5 XTMCXFA11
220V 230V 240V
e
380V 400V 415V 500V
Contact Configuration Contact Sequence
51
61
62
52
Pkg. Qty.
1
Screw Terminal Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
10 4 2 1.5 2NO 5 XTMCXFA20
10 4 2 1.5 4NC 5 XTMCXFA04
10 4 2 1.5 1NO-3NC 5 XTMCXFA13
10 4 2 1.5 2NO-2NC 5 XTMCXFA22
10 4 2 1.5 3NO-1NC 5 XTMCXFA31
10 4 2 1.5 4NO 5 XTMCXFA40
10 4 2 1.5 1NO-1NC
Notes
1
Orders must be placed in multiples of package quantity listed.
2
One early-make contact (NOE), one late-break contact (NCL).
1NO
E
-1NC
L
53
546364
5 XTMCXFAL22
2
1
1
1
1
1
1
V5-T1-6 Volume 5—Motor Control and Protection CA08100006E—April 2016
IEC Contactors and Starters
Two - Po le
Four-Pole
4
51
52
61
62
5
54
53 61
627374
83
84
54
53
61
62
717283
84
XT IEC Power Control
1.1
Front-Mount Auxiliary Contacts for Use with XTRE Control Relays
Rated Operational Current AC-15 I
Conventional Thermal Current,
(A), Open at 60°C Poles
I
th
16 2 6 3 1.5 2NO 5 XTCEXFAC20
16 2 6 3 1.5 1NO-1NC 5 XTCEXFAC11
16 2 6 3 1.5 2NC 5 XTCEXFAC02
16 2 6 3 1.5 1NO
16 4 6 3 1.5 4NO 5 XTCEXFAC40
16 4 6 3 1.5 3NO-1NC 5 XTCEXFAC31
16 4 6 3 1.5 2NO-2NC 5 XTCEXFAC22
16 4 6 3 1.5 1NO-3NC 5 XTCEXFAC13
16 4 6 3 1.5 4NC 5 XTCEXFAC04
16 4 6 3 1.5 1NO-1NC
220V 230V 240V
380V 400V 415V 500V
(A)
e
Contact Configuration Circuit Symbol
-1NC
E
-1NC
1NO
E
1
Pkg. Qty.
63
53
6
54
61
53
62
54
L
L
57 6
66
58
53
63 73
64
54
536171
54
62
515261
62
65
57
66
58
83
84
74
82
72
71
81
72
82
717283
81
84
5 XTCEXFALC11
5 XTCEXFCLC22
2
Screw Terminal Catalog Number
1
1
1
1
3
1
1
1
4
1
3
3
1
1
1
3
1
1
1
1
4
1
1
Notes
1
Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules (not NOE and NCL contacts) and between the auxiliary contacts and built-in contacts of the XTRE control relays.
2
Orders must be placed in multiples of package quantity listed.
3
Catalog number is shown with screw type terminal. For spring cage, add a “C” before the last 2 digits. For example, to order a spring cage version of the XTCEXFAC22, change the catalog number to XTCEXFACC22.
4
One early-make contact (NOE), one late-break contact (NCL).
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—April 2016 V5-T1-7
Loading...
+ 4 hidden pages