Cutler Hammer, Div of Eaton Corp XTFR Parts List

IEC Contactors and Starters
1.2
XTFR Reversing Combination Motor Controllers—Component Bill of Material
1
Factory Assembled Manual Motor Protector + Contactor + Line Side Adapter
1
Assembled Combination Motor Controller
1
XTFR Frame B MMP + Frame B Contactor
XTFRP16BB_ 0.1–0.16 XTPAXLSA XTPRP16BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11
1
XTFRP25BB_ 0.16–0.25 XTPAXLSA XTPRP25BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11
XTFRP40BB_ 0.25–0.4 XTPAXLSA XTPRP40BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11
1
XTFRP63BB_ 0.4–0.63 XTPAXLSA XTPRP63BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11
1
XTFR001BB_ 0.63–1 XTPAXLSA XTPR001BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11
XTFR1P6BB_ 1–1.6 XTPAXLSA XTPR1P6BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11
1
XTFR2P5BB_ 1.6–2.5 XTPAXLSA XTPR2P5BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11
XTFR004BB_ 2.5–4 XTPAXLSA XTPR004BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11
1
XTFR6P3BB_ 4–6.3 XTPAXLSA XTPR6P3BC1 XTPAXTPCRB (2) XTCE007B01_ XTPAXFA11
XTFR010BB_ 6.3–10 XTPAXLSA XTPR010BC XTPAXTPCRB (2) XTCE009B01_ XTPAXFA11
1
XTFR012BB_ 8–12 XTPAXLSA XTPR012BC1 XTPAXTPCRB (2) XTCE012B01_ XTPAXFA11
1
XTFR Frame B MMP + Frame C Contactor
XTFR016BC_ 10–16 XTPAXLSA XTPR016BC1 XTPAXTPCRC (2) XTCE018C01_ XTPAXFA11
1
XTFR020BC_ 16–20 XTPAXLSA XTPR020BC1 XTPAXTPCRC (2) XTCE025C01_ XTPAXFA11
XTFR025BC_ 20–25 XTPAXLSA XTPR025BC1 XTPAXTPCRC (2) XTCE025C01_ XTPAXFA11
1
XTFR032BC_ 25–32 XTPAXLSA XTPR032BC1 XTPAXTPCRC (2) XTCE032C01_ XTPAXFA11
1
XTFR Frame D MMP + Frame C Contactor
XTFR016DC_ 10–16 XTPAXLSAD XTPR016DC1
1
XTFR025DC_ 16–25 XTPAXLSAD XTPR025DC1
XTFR032DC_ 25–32 XTPAXLSAD XTPR032DC1
1
XTFR Frame D MMP + Frame D Contactor
XTFR040DD_ 32–40 XTPAXLSAD XTPR040DC1
1
XTFR050DD_ 40–50 XTPAXLSAD XTPR050DC1
1
XTFR058DD_ 50–58 XTPAXLSAD XTPR058DC1
XTFR063DD_ 55–65 XTPAXLSAD XTPR063DC1
1
Notes
1
1
Underscore (_) indicates magnetic coil suffix required. See Page V5-T1-204.
The connection between the XTPR…DC1 and the XTCE…C_ contactor will be made with flexible wire and mounted to the DIN rail adapter plate (XTPAXTPCPD).
The reversing connection between the XTPR…DC1 and the (2) XTCE…C_ contactors will be accomplished by using the non-reversing combination connection kit (XTPAXTPCD), Frame D reversing link kit (XTCEXRLD), additional DIN rail adapter plate (XTPAXTPCPD) and DIN adapter connection element (XTPAXCNE).
XT IEC Power Control
FLA Adjustment Range/ Overload Release—I (Amps)
r
Component Catalog Numbers Line Side
Adapter
Manual Motor Protector
Combination Connection Kit Contactor
(2) XTCE018C01_ XTPAXFA11
(2) XTCE025C01_ XTPAXFA11
(2) XTCE032C01_ XTPAXFA11
(2) XTCE040D00_ XTPAXFA11
(2) XTCE050D00_ XTPAXFA11
(2) XTCE065D00_ XTPAXFA11
(2) XTCE065D00_ XTPAXFA11
Manual Motor Protector Auxiliary Contact
1
1
1
1
1
1
1
1
1
1
Loading...