Cutler Hammer, Div of Eaton Corp Series G General Product Line Information

Series G molded-case circuit breakers
UL 489 solution
Featuring the EG: The Industry’s Smallest 125A UL Breaker
Earth Leakage Module
Applications
Series G molded-case circuit breakers provide the world’s most comprehensive product solutions for applications from 15 to 2500A at 208 to 690V.
Branch circuit protection
Series G molded-case circuit breakers provide for the protection of cable, and meet or exceed the requirements of the NEC for branch circuit protection.
Series G UL 489 molded-case circuit breakers exceed the requirements of the NEC for use as disconnecting means in branch and motor branch circuits.
Circuit breaker mounting
EG-Frame circuit breakers can be DIN rail mounted, or base or front panel mounted. All other Series G frame breakers can be panel mounted.
30 mA ground fault (earth leakage) modules
Eaton offers a UL Listed Earth Leakage Solution consisting of a three- and four-pole 30 mA ground fault (earth leakage) protection module for EG, JG and LG breakers, while not restricting the use of other breaker accessories.
Standards
Series G molded-case circuit breakers are available in versions that meet all major electrical standards of the world.
UL Listed
Series G molded-case circuit breakers meet NEMAT design
standards. They are tested and listed per UL 489, ensuring conformance with the NEC.
CSAT Certied
Series G molded-case circuit breakers are certified in
accordance with CSA 22.2 No. 5-02.
IEC 60947-2 CE Mark
Eaton’s world-class Series G molded-case circuit breakers
exceed the performance specifications of IEC 60947-2. They carry the CE mark for applications where European compliance is required.
China Compulsory Certied
The China Compulsory Certificate mark (CCC Mark) is a
compulsory safety mark for many products sold on the Chinese market.
IEC Third-Party Certication
In addition to self certification to IEC 60947-2 standard,
Eaton’s Series G circuit breakers are witness tested by certified third-party IEC test labs. Please check Eaton’s Web site for a list of available certificates.
Technology
Series G employs the world’s most advanced molded-case circuit breaker technology. Patented reverse loop contact designs provide for current limiting performance and the highest interrupting ratings in the industry’s most compact breaker sizes.
Series G molded-case circuit breaker accessories
UL 489 solution
Series G breaker frame capabilities
Maximum Voltages Maximum Interrupting Ratings
Frame
E 125 600Y/347 415 200 kA 100 kA 35 kA 200 kA 100 kA N/A 5.50 3.00 2.99 J 250 600 690 200 kA 200 kA 50 kA 200 kA 200 kA 18 kA 7.00 4.13 3.57 L 600 600 690 200 kA 200 kA 65 kA 200 kA 200 kA 35 kA 10.13 5.48 4.09 N 1200 600 690 200 kA 150 kA 65 kA 200 kA 100 kA 35 kA 16.00 8.25 5.50 R 2500 600 690 200 kA 100 kA 65 kA 200 kA 100 kA 35 kA 16.00 15.50 9.75
A
Maximum Amperes
Per UL and CSA listed ratings.
NEMA,
A
UL, CSA IEC 60947-2 UL 240V UL 480V UL 600V IEC 240V IEC 415V IEC 690V H W D
Dimensions in Inches Three Poles
Series G accessories
Termination Options and Accessories
Control panel and enclosure accessories
Flex Shaft
High Performance Handle with Padlocks
Power Distribution Blocks
Universal Rotary
Accessories
Series G breakers are available with a comprehensive range of accessories, including shunt trips, undervoltage releases, alarm lockout and auxiliary switches, multi-wire lug kits, control wire terminal kits, etc., that are field installable.
Plug-in blocks
Plug-in adapters simplify installation and front removal of circuit breakers. Plug-ins are available for rear connection applications on three- and four-pole circuit breakers. Trip-on drawout interlock kits are included. Stabs for EG, JG and LG plug-ins rotate 90° for flexible installation. Use terminal shields for IP30 protection.
Flex ShaftE handle mechanism
Flex Shaft handle mechanisms make installing and operating enclosure-mounted breakers easier than ever. Installation and adjustment of this flange­mounted mechanism can be accomplished in about 10 minutes or less. Optional early break auxiliary switch handle is available. Use for Type 1, 12, 4 and 4X environments.
High-performance handle mechanism
In addition to its robust design features, the handle mechanism has stand-off support that allows for easy operation with a gloved hand. Use for Type 1, 12, 3R or 4X environments. The high performance external handle can accept padlocks or multi-hasp locks.
Power distribution blocks
Eaton power distribution blocks are designed for high short-circuit current rating applications when applied with Series G breakers. Available in three-pole open style and single­pole enclosed style with a variety of terminal arrangements and current-carrying capability up to 570A.
Rotary door-mounted handle mechanism
Rotary handle mechanisms are available for EG-, JG-, LG­and NG-Frame breakers. Use for Type 1 and 12 environments. This rugged through-the-door rotary handle mechanism is designed to accommodate a gloved hand.