Cutler Hammer, Div of Eaton Corp Series C Moulded Case Circuit Breakers Catalog Page

Series C Moulded Case Circuit Breakers
70-600 Amperes L-Frame
Typical L-Frame Circuit Breaker
Product Description
All L-frame circuit breakers are HACR rated.
L-frame circuit breakers are available as individual components (Frame, Trip Unit, Terminals), or factory assembled complete breakers. OPTIM circuit breakers are available as factory assembled only.
L-frame circuit breakers are suitable for reverse feed use.
Technical Data and Specifications
CSA C22.2 No. 5 and UL489 Interrupting Capacity Ratings
Interrupting Capacity (RMS Symmetrical Amperes) (kA)
Circuit Breaker Type
LD CLD
HLD CHLD
LDC
CLDC
IEC 947-2 Interrupting Capacity Ratings
Circuit Breaker Type
LD 2, 3, 4 I
CLD
HLD 2, 3, 4 I
CHLD
LDC 2, 3, 4 I
CLDC
Number of Poles
2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4
2, 3, 4 2, 3, 4
Number of Poles
2, 3, 4 I
2, 3, 4 I
2, 3, 4 I
Volts Ac (50/60 Hz) Volts Dc
240 277 480 600 125 250
65 65 100 100
200 200
cu
I
cs
cu
I
cs
cu
I
cs
cu
I
cs
cu
I
cs
cu
I
cs
– – – –
– –
35 35 65 65
100 100
Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz) Volts Dc
240 415 690 250
85 85
85 85
100 100
100 100
200 100
200 100
25 25 35 35
50 50
45 45
45 45
70 70
70 70
100 75
100 75
49
49
Section Page
➁➂
Number
– – – –
– –
22 – 25 –
30 –
L-4,5,7 L-5,9 L-4,5,7 L-5,9
L-4,5,8 L-5,10
49
49
49
49
49
49
Section
➁➂
20 10
20 10
25 13
25 13
35 18
35 18
20 10
– –
20 10
– –
20 10
– –
Page Number
L-4,5,7
L-5,9
L-4,5,7
L-5,9
L-4,5,8
L-5,10
49
49
49
49
49
49
49
Utilization category A circuit breakers.
L/R = 8 milliseconds minimum.
2-pole circuit breaker or two poles of 3-pole circuit breaker. Incorporating Thermal-Magnetic trip unit only.
100% rated breakers.
Current limiting.
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
Series C and Special Application Moulded Case Circuit Breakers
PG01200001K—October 2011
41
Series C Moulded Case Circuit Breakers
70-600 Amperes L-Frame
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
L-Frame Digitrip Specifications
Trip Unit Type Digitrip RMS 310 Digitrip OPTIM 550 Digitrip OPTIM 1050
RMS Sensing Yes Yes Yes
Breaker Type
Frame L L L
Ampere Range 300-600A 200-600A 70-600A
Interrupting Rating @ 600V 25, 35, 50 (kA) 25, 35, 50 (kA) 25, 35, 50 (kA)
Protection
Ordering Options LS, LSG LSI, LSIG LSI, LSI(A), LSIG LSI(A), LSIG
Fixed Rated Plug (In) Yes Yes Yes Yes
Overtemperature Trip Yes Yes Yes Yes
Long Delay Protection (L)
Adjustable Rating Plug (I
Long Delay Pickup 0.5-1.0 (In)
Long Delay Time I
Long Delay Time I4t No No 1-5 Seconds 1-5 Seconds
Long Delay Thermal Memory Yes Yes Yes Yes
High Load Alarm No No 0.5-1.0 x I
Short Delay Protection (S)
Short Delay Pickup 200-800% x (In) 200-800% x (In) 150-800% x (Ir) 150-800% x (Ir)
Short Delay Time I2t 100 ms No 100-500 ms 100-500 ms
Short Delay Time Flat No Inst-300 ms 100-500 ms 100-500 ms
Short Delay Time Zone Selective Interlocking No No Yes
Instantaneous Protection (I)
Instantaneous Pickup No 200-800% x (In) 200-800% x (In) 200-800% x (In)
Discriminator No No Yes Yes
Instantaneous Override Yes Yes Yes Yes
Ground Fault Protection (G)
Ground Fault Alarm No No 20-100% x (Is) 20-100% x (Is)
Ground Fault Pickup 1-5 x 1g (120A) 1-5 x 1g (120A) 20-100% x (Is) 20-100% x (Is)
Ground Fault Delay I2t No No 100-500 ms 100-500 ms
Ground Fault Delay Flat Inst-500 ms Inst-500 ms 100-500 ms 100-500 ms
Ground Fault Zone Selective Interlocking No No Yes
Ground Fault Thermal Memory Yes Yes Yes Yes
System Diagnostics
Status LEDs Yes Yes Yes Yes
Cause of Trip LEDs No No Yes Yes
Magnitude of Trip Information No No Yes Yes
Remote Signal Contact – Ground Alarm Yes
Local Auxiliary and Bell Alarm Contact Optional Optional Optional Included
System Monitoring
Digital Display No No Yes
Current No No Yes Yes
Power and Energy No No No Yes
Power Quality-Harmonics No No No Yes
Power Factor No No No Yes
Communications
Eaton PowerNet No No Yes
Testing
Testing Method Test Set OPTIMizer, BIM, Eaton PowerNet
Adjust by rating plug.
By OPTIMizer/BIM.
Require Eaton PowerNet kit.
Require Zone interlock kit.
With separate ground fault alarm unit (GFAU).
) Yes Yes No No
n
2
t 12 Seconds 12 Seconds 2-24 Seconds 2-24 Seconds
Legend: BIM = Breaker Interface Module (A) = GF Alarm
0.5-1.0 (In)
Yes
0.4-1.0 x (In) 0.4-1.0 x (In)
r
Yes
➃➄
= Sensor Rating
I
s
= Rating Plug
I
n
Ir = Long Delay Pickup Setting
0.5-1.0 x I
Yes
Yes
Yes
Yes
Yes
r
42 Series C and Special Application Moulded Case Circuit Breakers
PG01200001K—October 2011
Series C Moulded Case Circuit Breakers
70-600 Amperes L-Frame
Catalogue Numbering System
This information is presented only as an aid to understanding Catalogue numbers. It is not to be used to build Catalogue numbers for circuit breakers or trip units.
Thermal-Magnetic Trip Unit Catalogue NumberCircuit Breaker/Frame Catalogue Number
LD
3 600 F LT 3 400 T
Circuit
Breaker/
Frame Type
LD
HLD
LDC
CLD
CHLD
CLDC
“VISA option is available. CSA listed only.
Number
of Poles
2: 2 Poles 3: 3 Poles 4: 4 Poles
Circuit Breaker/Frame Ampere Rating
300 350 400 450 500 600
F: Frame Only WK: High Magnetic Moulded
V: 50°C (Thermal-Magnetic
FS: VISA - Frame only. SKW: VISA - High Magnetic
Suffix
Case Switch without terminals
Trip Units Only)
Moulded Case Switch without terminals
Trip Unit Type
LT:Thermal-
Magnetic
Number of Poles
2: 2 Poles 3: 3 Poles 4: 4 Poles
OPTIM Circuit Breaker/Frame Catalogue Number Digitrip RMS 310 Trip Unit Catalogue Number
Circuit
Breaker/
Frame
Type
LD HLD LDC CLD CHLD CLDC
Number of Poles
3: 3 Poles
LD
3 125 T5 7 W
Circuit
Breaker/
Frame
Ampere
Rating
125 (Available on Model 1050 only)
250 (Available on Model 1050 only)
400
600
Trip Model
T5 – Model 550
T10 – Model 1050
Trip Type
2 – LSI (550 only) 6 – LSIG 7 – LSIA
Suffix
W:Without Terminals
Trip Unit Type
LES:Electronic
LES
Number of
Poles
3: 3 Poles 4: 4 Poles
Trip Unit/
Rating Plug
Ampere
Rating
300 350 400 450 500 600
T: Trip Unit Thermal-Magnetic
TV: 50°C Calibration (Thermal-
3 600 LS P
Trip Unit
Ampere
Rating
600
Suffix
LS LSI LSG LSIG
Suffix
Fixed Thermal Adjustable Magnetic
Magnetic Trip Units Only)
Suffix
P: 100% Protected
Neutral on 4-Pole Trip Unit
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
Dimensions/Weights
Dimensions, Inches (mm)
Number of Poles Width Height Depth
2, 3 8.25
4 11
Approximate Shipping Weight, Lbs. (kg)
Complete Breaker Frame Only Trip Unit
Breaker Type
LD, HLD, LDC
Series C and Special Application Moulded Case Circuit Breakers
Number of Poles
234234234
18 (8.172)20(9.080)25(11.340)14(6.356)15(6.810)20(9.072)3(1.361)4(1.814)5(2.268)
(210)
(279)
10.75 (274)
10.75 (274)
PG01200001K—October 2011
4.062 (103)
4.062 (103)
49
49
49
49
49
49
49
49
49
43
Series C Moulded Case Circuit Breakers
70-600 Amperes L-Frame
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
49
Product Selection
Types LD, HLD, and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
Standard Interrupting Capacity 600 Vac Rated 25 kAIC @600 Vac
Factory Assembled Circuit Breaker
Maximum Continuous Ampere Rating @ 40°C
2-Pole
300 350 400 450 500 600
3-Pole
300 350 400 450 500 600
4-Pole
300 350 400 450 500 600
Instruction Leaflet Number 29C105 for Breaker; 29C607 for Thermal Magnetic Trip Unit
Consisting of Frame, Trip Unit, and Terminals
Catalogue Number
LD2300 LD2350 LD2400 LD2450 LD2500 LD2600
LD3300 LD3350 LD3400 LD3450 LD3500 LD3600
LD4300 LD4350 LD4400 LD4450 LD4500 LD4600
Frame
Only
LD2600F HLD2300
LD3600F HLD3300
LD4600F HLD4300
High Interrupting Capacity 600 Vac Rated 35 kAIC @ 600 Vac
Factory Assembled Circuit Breaker Consisting of Frame, Trip Unit, and Terminals
HLD2350 HLD2400 HLD2450 HLD2500 HLD2600
HLD3350 HLD3400 HLD3450 HLD3500 HLD3600
HLD4350 HLD4400 HLD4450 HLD4500 HLD4600
Frame
Only
HLD2600F LDC2300
HLD3600F LDC3300
HLD4600F LDC4300
Ultra High Interrupting Capacity Current Limiting 600 Vac Rated 50 kAIC @ 600 Vac
Factory Assembled Circuit Breaker Consisting of Frame, Trip Unit, and Terminals
LDC2350 LDC2400 LDC2450 LDC2500 LDC2600
LDC3350 LDC3400 LDC3450 LDC3500 LDC3600
LDC4350 LDC4400 LDC4450 LDC4500 LDC4600
Frame Only
LDC2600F LT2300T
LDC3600F LT3300T
LDC4600F LT4300T
Thermal Magnetic Trip Unit Only
For Use With: Standard or High or Ultra High Interrupting Frames
Magnetic Trip Range is 5-10 x Continuous Ampere Rating
LT2350T LT2400T LT2450T LT2500T LT2600T
LT3350T LT3400T LT3450T LT3500T LT3600T
LT4350T LT4400T LT4450T LT4500T LT4600T
Standard Terminals Only
See Section Page Number L-11 for Optional Terminals
TA602LD TA602LD
TA602LD
TA602LD
TA602LD
2TA603LDK
TA602LD TA602LD TA602LD TA602LD TA602LD 3TA603LDK
TA602LD TA602LD TA602LD TA602LD TA602LD 4TA603LDK
➃ ➃ ➃ ➃ ➃
➃ ➃ ➃ ➃ ➃
49
49
49
49
49
49
49
49
49
49
49
49
49
When a “VISA” frame is required, add suffix “S” to circuit breaker frame catalogue number. LD and HLD only.
2-pole circuit breaker supplied in 3-pole frame.
Neutral is in right pole.
Individually packed.
Terminal kits contain one terminal for each pole and one terminal cover.
44 Series C and Special Application Moulded Case Circuit Breakers