Cutler Hammer, Div of Eaton Corp S751 Technical Data

Reduced Voltage Motor Starters Solid-State Reduced Voltage Starters
Open Soft Starters Intelligent Technologies (IT.) S751
Technical Data Specications
Table G-35. S751 Open Soft Staters
Soft Starter (Partial Catalog Number)
Maximum Current Capacity .8 1.9 4.4 9.0 16 27
Dimensions
Width in Inches (mm) 2.13 (54) 2.13 (54) 2.13 (54) 2.13 (54) 2.13 (54) 2.13 (54) Height in Inches (mm) 6.92 (175.7) 6.92 (175.7) 6.92 (175.7) 6.92 (175.7) 6.92 (175.7) 6.92 (175.7) Depth in Inches (mm) 4.13 (104.8) 4.13 (104.8) 4.13 (104.8) 4.13 (104.8) 4.13 (104.8) 4.13 (104.8) Weight in lbs. (kg) 2.80 (1.27) 2.80 (1.27) 2.80 (1.27) 2.80 (1.27) 2.80 (1.27) 2.80 (1.27) Drawing See
Electrical Characteristics
Line Voltage (V AC) 200 – 600 200 – 600 200 – 600 200 – 600 200 – 600 200 – 600 Operating Frequency (Hz) 47 – 63 47 – 63 47 – 63 47 – 63 47 – 63 47 – 63 Leakage Current 15 mA AC max. Min. Operating Current 100 mA Control Voltage (24V ±10%) 21.6 – 26.4 21.6 – 26.4 21.6 – 26.4 21.6 – 26.4 21.6 – 26.4 21.6 – 26.4 Response Time Max. 250 mS 250 mS 250 mS 250 mS 250 mS 250 mS Control Steady State Current 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA Inrush Current (During Bypass) 3.6A @ 50 mS 3.6A @ 50 mS 3.6A @ 50 mS 3.6A @ 50 mS 3.6A @ 50 mS 3.6A @ 50 mS
Control Wiring
Wire Sizes (AWG) 22 – 12 22 – 12 22 – 12 22 – 12 22 – 12 22 – 12 Number of Conductors (Stranded) 2 (or one AWG 12) T orque Requirements (lb-in) 3.5 3.5 3.5 3.5 3.5 3.5 Solid, Stranded or Flexible Max. Size
(mm2)
Cabling Capacity
Number of Conductors 111111 Wire Sizes 14 – 8 14 – 8 14 – 8 14 – 8 14 – 8 14 – 8 Type of Connectors Box Lugs Box Lugs Box Lugs Box Lugs Box Lugs Box Lugs
Environmental Characteristics
T emperature — Operating (no derating) -35° – 50°C -35° – 50°C -35° – 50°C -35° – 50°C -35° – 50°C -35° – 50°C
G
T emperature — Derate >50°C (max. 65°C) -1/2% per°C -1/2% per°C -1/2% per°C -1/2% per°C -1/2% per°C -1/2% per°C T emperature — Storage -40° – 80°C -40° – 80°C -40° – 80°C -40° – 80°C -40° – 80°C -40° – 80°C Altitude (Meters) No Derating 2000 2000 2000 2000 2000 2000 Altitude > 2000M -1/2% per °C -1/2% per °C -1/2% per °C -1/2% per °C -1/2% per °C -1/2% per °C Humidity 95% Non-condensing Operating Position Vertical ± 30° Impulse Withstand Voltage IEC 947-4-1 4000V 4000V 4000V 4000V 4000V 4000V Rated Insulation Voltage (Ui) 660V Installation Category III Vibration IEC 68-2-6 3g 10 – 150 Hz Shock 15g 15g 15g 15g 15g 15g Degree of Protection IP20 IP20 IP20 IP20 IP20 IP20 Agency Approvals UL, CSA, CE
S751 L01
3.31 3.31 3.31 3.31 3.31 3.31
S751 L02
S751 L04
Figure G-5 (Page G-25
S751 L09
S751 L16
)
S751 L27
January 2003