Switching Devices
R9 Series (UL 98) Fusible 30–800A
Contents
Description Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . 28
Features, Benefits, and Functions . . . . . . . . . . . . . 28
Standards and Certifications . . . . . . . . . . . . . . . . . 28
Illustrations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Technical Data and Specifications . . . . . . . . . . . . . 39
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Product Overview
R9 Series (UL® 98 listed)
Fusible 30–800A manual
operated multi-pole fusible
disconnect switches use
double break contacts per
pole that ensure complete
isolation of the fuse when the
switch is in the OFF position.
When installed with fuses,
they provide protection for
low voltage electrical
installations against short
circuit and overload.
Features, Benefits
and Functions
●
Load break functionality
●
Double break contacts
●
Up to 200 kA short-circuit
rating with Class CC, J
or L fuses
●
Compact footprints
●
The optional TEST position
function (up to 400A)
enables testing of the
control circuit auxiliaries
without switching the main
contacts. This function
provides a simple
alternative to a separately
wired pushbutton
●
Defeatable pistol handles
automatically re-latch when
the panel door
is closed
●
Front or side operation
●
Flange operation
●
NFPA® 79 compliant kits
●
Two-, three- and fourpole devices
Standards and Certifications
●
UL 98, File E222859 for
30 to 800A ratings
●
UL 489, File E305341 for
H-Frame switches
●
CSA® 22.2 No. 4,
File 217736
●
CSA 22.2 No. 5,
File 217736, H-Frame only
●
IEC 60947-1, EN 60947-1
●
IEC 60947-3, EN 60947-3
●
CE mark
●
NFPA 79
28 Switching Devices PG00802002E—September 2012
Illustrations
R9 Fusible 30A/CC and 30A/J H-Frame—Direct and External Operation
1
External front handles
2
Direct handle
3
Shaft extensions for external handles
4
Configurable U Type ACs, for pre-break and signaling or TEST
Switching Devices
R9 Series (UL 98) Fusible 30–800A
R9 Fusible 30A/J–800A/L (I–N-Frames)—Direct and External Operation
1
External front handle
2
External right side handle (not applicable for N-Frame 600/800A)
3
Direct handle
4
Shaft extensions for external handles
5
Configurable U Type ACs, for pre-break and signaling or TEST
6
Side auxiliary contacts
7
Terminal shrouds
Switching Devices PG00802002E—September 2012 29