Cutler Hammer, Div of Eaton Corp R9 Series Data Sheet

Switching Devices
R9 Series (UL 98) Fusible 30–800A
Contents
Description Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . 28
Features, Benefits, and Functions . . . . . . . . . . . . . 28
Standards and Certifications . . . . . . . . . . . . . . . . . 28
Illustrations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Technical Data and Specifications . . . . . . . . . . . . . 39
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Product Overview
R9 Series (UL® 98 listed) Fusible 30–800A manual operated multi-pole fusible disconnect switches use double break contacts per pole that ensure complete isolation of the fuse when the switch is in the OFF position.
When installed with fuses, they provide protection for low voltage electrical installations against short circuit and overload.
Features, Benefits and Functions
Load break functionality
Double break contacts
Up to 200 kA short-circuit rating with Class CC, J or L fuses
Compact footprints
The optional TEST position function (up to 400A) enables testing of the control circuit auxiliaries without switching the main contacts. This function provides a simple alternative to a separately wired pushbutton
Defeatable pistol handles automatically re-latch when the panel door is closed
Front or side operation
Flange operation
NFPA® 79 compliant kits
Two-, three- and four­pole devices
Standards and Certifications
UL 98, File E222859 for 30 to 800A ratings
UL 489, File E305341 for H-Frame switches
CSA® 22.2 No. 4, File 217736
CSA 22.2 No. 5, File 217736, H-Frame only
IEC 60947-1, EN 60947-1
IEC 60947-3, EN 60947-3
CE mark
NFPA 79
28 Switching Devices PG00802002E—September 2012
Illustrations
1
2
3
4
1
2
3
4
5
6
7
4
R9 Fusible 30A/CC and 30A/J H-Frame—Direct and External Operation
1
External front handles
2
Direct handle
3
Shaft extensions for external handles
4
Configurable U Type ACs, for pre-break and signaling or TEST
Switching Devices
R9 Series (UL 98) Fusible 30–800A
R9 Fusible 30A/J–800A/L (I–N-Frames)—Direct and External Operation
1
External front handle
2
External right side handle (not applicable for N-Frame 600/800A)
3
Direct handle
4
Shaft extensions for external handles
5
Configurable U Type ACs, for pre-break and signaling or TEST
6
Side auxiliary contacts
7
Terminal shrouds
Switching Devices PG00802002E—September 2012 29
Loading...