Pushbuttons and Indicating Lights
47.4
Technical Data and Specifications
47
Pushbuttons, Indicating Lights, Selector Switches and Emergency-Stop Operators
47
Description
47
General
Standards IEC/EN 60947
47
Lifespan, mechanical Operations x 10
47
Operating frequency Operations/h ≥3600 ≥1800 — ≥600 ≥2000 ≥100 ≥3600
Actuating force n ≥5 ≥5— ≥50 – — ≥5
47
Operating torque
(screw terminals)
Protection Type
47
IP IP67, IP69K IP67, IP69K Indicating lights: IP67, 69K
47
UL type 4X, 13 4X, 13 Indicating lights: 4X/13
47
Climatic proofing Damp heat, constant, according to IEC 60068-2-78
47
Ambient temperature,
47
operating
Mounting position As required As required As required As required As required As required As required
47
Mechanical shock
resistance to
IEC 60068-2-27
47
shock duration 11 ms,
half-sinusoidal
47
Terminal Capacities
Solid AWG — — 20-16 ————
47
Stranded AWG — — 20-16 ————
47
Contacts
47
Rated impulse withstand
voltage
47
Rated insulation voltage U
Overvoltage category/
pollution degree
47
22.5 mm Modular Pushbuttons—M22
Momentary
Pushbuttons
VDE 0660
6
>5 >1 — >0.1 >0.1 >0.1 >0.2
Nm——— —≥0.3 ≥0.5 —
Damp heat, cyclical to IEC 60068-2-30
°F
–13 to 158
(°C)
(–25 to 70)
g >30 >30 >30 >50 >30 >30 >30
2
mm
2
mm
U
imp
i
Vac — — 4000 ————
V — — 2500 ————
— — III/3 ————
Maintained
Pushbuttons
IEC/EN 60947
VDE 0660
–13 to 158
(–25 to 70)
— 0.5–1.5 — —
— 0.5–1.5 — —
Indicating Lights,
Buzzers and
Potentiometers
IEC/EN 60947
VDE 0660
Buzzers: IP40
Potentiometers: IP66
Buzzers: 12
Potentiometers: 4X/13
–13 to 158
(–25 to 70)
Emergency-Stop
Operators
IEC/EN 60947
VDE 0660
IP67, IP69K IP66 IP66 IP66
4X, 13 4X, 13 4X, 13 4X, 13
–13 to 158
(–25 to 70)
Selector
Switches
IEC/EN 60947
VDE 0660
–13 to 158
(–25 to 70)
Key-Operated
Operators
IEC/EN 60947
VDE 0660
–13 to 158
(–25 to 70)
Double
Pushbuttons
IEC/EN 60947
VDE 0660
–13 to 158
(–25 to 70)
47
47
47
47
47
47
47
47
47
47
47
104 Control Products Catalog CA08102001E—August 2010 www.eaton.com
Pushbuttons and Indicating Lights
22.5 mm Modular Pushbuttons—M22
47.4
Contact Blocks and Light Units
Description
General
Standards IEC/EN 60947
Lifespan, mechanical Operations x 10
Operating frequency Operations/h ≥3600 —
Actuating force n ≥5—
Operating torque (screw terminals) Nm ≥0.8 —
Protection Type
IP IP20 IP20
UL type — —
Climatic proofing Damp heat, constant, according to IEC 60068-2-78
Ambient temperature, operating °F (°C) –13 to 158 (–25 to 70) –13 to 158 (–25 to 70)
Mounting position As required As required
Mechanical shock resistance to
IEC 60068-2-27 shock duration
11 ms, half-sinusoidal
Terminal Capacities
Solid AWG 18–14 18–14
Stranded AWG 20–14 20–14
Contacts
Rated impulse withstand voltage U
Rated insulation voltage U
Overvoltage category/
pollution degree
NEMA contact ratings A600, Q300 —
Current draw — 5–15 mA
Control Circuit Reliability
at 24 Vdc/5 mA H
at 5 Vdc/1 mA H
Max. Short-Circuit Protective Device
Fuse gG/gL A 10 —
Switching Capacity
Rated Operational Current
AC-15
115V I
230V I
400V I
500V I
DC-13
24V I
42V I
60V I
110V I
220V I
Lifespan, Electrical
AC-15
230V/0.5A Operations x 10
230V/1.0A Operations x 10
230V/3.0A Operations x 10
DV-13
12V/2.8A Operations x 10
imp
i
F
F
e
e
e
e
e
e
e
e
e
6
g >30 >30
2
mm
2
mm
Vac 6000 6000
V 500 500
Fault probability <10-7, <1 fault in 107 operations —
Fault probability <5 x 10-6, <1 fault in 5 x 106 operations —
A6 —
A6 —
A4 —
A2 —
A3 —
A 1.7 —
A 1.2 —
A 0.8 —
A 0.3 —
6
6
6
6
Contact
Blocks
VDE 0660
>5 —
Damp heat, cyclical to IEC 60068-2-30
0.75–2.5 0.75–2.5
0.5–2.5 0.5–2.5
III/3 III/3
1.6 —
1—
0.7 —
1.2 —
LED
Light Units
IEC/EN 60947
VDE 0660
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
47
Contact Element Note: >200 Vac/60 Hz: –25/55°C
47
47