IEC Contactors & Starters
IT. Electro-Mechanical
July 2008
Catalogue Number Selection
Catalogue Number Selection (Open Components)
Table B-206. IT. Electro-Mechanical Catalogue Numbering System
E 101 A 12 A 3 A
B-179
Standard
E = IEC
Configuration (Open Type)
02N = FVNR Coil Controller
03N = FVR Coil Controller
04N = Contact Block
05N = Solid-State Non-reversing Overload Relay
06N = Solid-State Reversing Overload Relay
101 = FVNR Starter
111 = FVNR Contactor
501 = FVR Starter
511 = FVR Contactor
Frame Size
A = 27 mm
B = 45 mm
C = 54 mm
D = 76 mm
E = 105 mm
F = 140 mm
(A)
06 = 6 Amps.
09 = 9 Amps.
12 = 12 Amps.
(B)
18 = 18 Amps.
25 = 25 Amps.
32 = 32 Amps.
(C)
40 = 40 Amps.
50 = 50 Amps.
(D)
65 = 65 Amps.
85 = 85 Amps.
10 = 100 Amps.
Designator (IEC)
(E)
12 = 125 Amps.
16 = 160 Amps.
20 = 200 Amps.
(F)
25 = 250 Amps.
31 = 315 Amps.
42 = 420 Amps.
XC = Coil Controller
XR = Overload
A = Standard
(3-phase, 45 mm – 105 mm; 1- or 3-phase, 27 mm)
N = Contactor or Not Applicable
Pole Selection
3 = 3-Pole
Overload Amperes Adjustment
(27 mm)
A = .25 – .8
B = .59 – 1.9
C = 1.4 – 4.4
D = 2.8 – 9.0
E = 3.8 – 12
(45 mm)
A = .25 – .8
B = .59 – 1.9
C = 1.4 – 4.4
D = 2.8 – 9.0
G = 6.3 – 20
J = 10 – 32
(54 mm)
A = .25 – .8
B = .59 – 1.9
C = 1.4 – 4.4
D = 2.8 – 9.0
F = 5.0 – 16
H = 8.4 – 27
L = 16 – 50
(76 mm)
F = 5.0 – 16
H = 8.4 – 27
K = 14 – 45
N = 31 – 100
(105 mm)
K = 14 – 45
M = 28 – 90
P = 42 – 135
R = 63 – 200
(140 mm)
P = 42 – 135
S = 84 – 270
T = 131 – 420
X = Contact Block, Coil
Controller, Contactor or
Not Applicable
Overload Type
B
Note: When using the Catalogue Numbering System for Eaton’s Cutler-Hammer IT. Electro-Mechanical products, care should be exercised to
assure that the Catalogue Number for the Overload Relay aligns with the IT. Contact Block selected for type, frame size and ampacity, if pur-
chased as separate components. Example: Select an E05N_XR_3A IT. Overload Relay for an IEC non-reversing application or an E06N_XR_3A
for an IEC reversing application.
Examples:
E02NCXCXNN — FVNR Coil Controller, 54 mm
E04NB18X3N — Contact Block, 45 mm, 18 Amps
E05NCXRL3A — Solid-State Non-reversing Overload Relay, 16 – 50 Amps
E101B32J3A — FVNR B-Frame Starter, 32 Amps, with Solid-State Overload, 10 – 32 Amps
E111F25X3N — FVNR F-Frame Contactor, 250 Amps
E501D10K3A — FVR D-Frame Starter, 100 Amps, with Solid-State Overload, 14 – 45 Amps
E511B18X3N — FVR B-Frame Contactor, 18 Amps
CA08102002K

B-180
B
IEC Contactors & Starters
IT. Electro-Mechanical
Contactors — Full Voltage, Non-reversing and Reversing
Contents
Description Page
Product Family Overview
Product Description. . . . . . . B-178
Standards and
Certifications . . . . . . . . . . . B-178
Publications . . . . . . . . . . . . . B-178
Catalogue Number
Selection . . . . . . . . . . . . . . B-179
Contactors — Non-reversing
and Reversing
Product Description. . . . . . . B-180
Application Description. . . . B-180
Features . . . . . . . . . . . . . . . . B-180
Product Selection. . . . . . . . . B-181
Technical Data and
Specifications . . . . . . . . . . . . . B-190
Accessories . . . . . . . . . . . . . . . . B-194
Auxiliary Contacts . . . . . . . . B-196
Renewal Parts. . . . . . . . . . . . . . B-198
Wiring Diagrams. . . . . . . . . . . . B-199
Dimensions . . . . . . . . . . . . . . . . B-200
IEC Full Voltage Non-reversing
Contactor, C-Frame
Cat. No. E111C50X3N
Product Description
The Cutler-Hammer® Intelligent
Technologies (IT.) Electro-Mechanical
Contactor from Eaton’s electrical
business consists of an IT. Electro-
Mechanical Contact Block and IT.
Electro-Mechanical Coil Controller
as a Full Voltage Non-reversing
(FVNR) or Full Voltage Reversing
(FVR) device. B-Frame (45 mm) to
E-Frame (105 mm) Contact Blocks
combined with Coil Controllers
(factory or field assembled) are
stand-alone Contactors. Only the
A-Frame (27 mm) and F-Frame
(140 mm) Contactors have internal
factory assembled coil controllers.
Also available are the
Combination Motor Controllers which
combine a Manual Motor Protector,
Wiring Connector Link and
tor.
Application Description
When selecting an IEC Contactor, the
user must consider the specific load,
utilization category and required electrical life. Actual application life July
vary depending on environmental
conditions and duty cycle.
Features
■
■
■
■
■
■
■
IT.
Manual and
IT.
Contac-
115V AC – 600V AC, 1/4 – 350 hp/
3/4 – 250 kW, 50/60 Hz
24V DC Coil Control — safe, reliable
global standard
Most compact DC operated contactors available — e.g., A-Frame
27 mm wide, 7-1/2 hp @ 12A, 460V
Frame sizes (mm): 27, 45, 54, 76, 105,
140
No laminations, shading coils or
magnet noise
-40 to 149°F (-40 to 65°C)
operating temperature
No seal in auxiliary contacts
required — control wiring is not
needed between the contactor and
overload relay
July 2008
Unique Pulse Width Modulated
■
(PWM) coil controller minimizes
energy and coil power consumption
Conformal coated PWM board
■
(coil controller) for environmental
toughness
Microprocessor-based control
■
■
95% humidity non-condensing
(99% consult factory)
■
Easily accessible mounting feet for
panel mounting
■
High immunity to ESD, harmonics —
minimal Total Harmonic Distortion
Front and side mounted Auxiliary
■
Contacts: 1NO, 1NC, 2NO, 2NC,
1NO/1NC and logic level
Built-in logic to provide either 2- or
■
3-wire control, eliminating the need
to provide and wire auxiliary contacts to seal in and interlock the
contactor coils
Easy field assembly of control
■
wiring — plug and unplug lockable
control connector
DIN rail mounting, 6 – 100A (A – D
■
Frames)
■
Common accessories
■
Long-life silver nickel (A – B Frames)
and silver tin oxide (C – F Frames)
contacts provide excellent conductivity and superior resistance to
welding and arc erosion
Environmentally friendly materials
■
IP20 Finger Protection
■
■
Low wattage coils and minimal heat
dissipation
Reversing Contactors
■
Includes Reversing Power Wiring
and bus bars
■
Mounting plates for B-Frame
(45 mm) to E-Frame (105 mm)
■
Exclusive internal electronic interlock for reversing
■
Unique coil controller energizes
both forward and reverse contactors
— one control point for wiring
IEC Full Voltage Reversing
Contactor, D-Frame
Cat. No. E511D10X3N
CA08102002K