Cutler Hammer, Div of Eaton Corp H-max Series Catalog Page

Catalog Number Selection
HMX 3 4 A G 3D4 2 1 -N
Software Series
A–Z
Keypad
G = Graphical panel
Voltage
2 = 200–240 V 4 = 380–480 V 5 = 525–600 V
Phase
3 = Three-phase
Product
HMX = HVAC drive
Enclosure
1 = Open NEMA Type 1 IP21 2 = Open NEMA Type 12 IP54
Input Options Frame and
Voltage Specific
2 =EMC C2
Braking/Application
N = No brake chopper (low overload)
Amperes
200–240 Volts 380–480 Volts 525–600 Volts
3D7 = 3.7 A–0.75 hp, 0.55 kW 4D8 = 4.8 A–1 hp, 0.75 kW 6D6 = 6.6 A–1.5 hp, 1.1 kW 8D0 = 8 A–2 hp, 1.5 kW
011 = 11 A–3 hp, 2.2 kW 012 = 12 A–4 hp, 3 kW 018 = 18 A–5 hp, 4 kW 024 = 24 A–7.5 hp, 5.5 kW 031 = 31 A–10 hp, 7.5 kW 048 = 48 A–15 hp, 11 kW 062 = 62 A–20 hp, 15 kW 075 = 75 A–25 hp, 18.5 kW 088 = 88 A–30 hp, 22 kW 105 = 105 A–40 hp, 30 kW 140 = 140 A–50 hp, 37 kW 170 = 170 A–60 hp, 45 kW 205 = 205 A–75 hp, 55 kW 261 = 261 A–100 hp, 75 kW 310 = 310 A–125 hp, 90 kW
3D4 = 3.4 A–1.5 hp, 1.1 kW 4D8 = 4.8–2 hp, 1.5 kW 5D6 = 5.6 A–3 hp, 2.2 kW 8D0 = 8 A–4 hp, 3 kW 9D6 = 9.6 A–5 hp, 4 kW
012 = 12 A–7.5 hp, 5.5 kW 016 = 16 A–10 hp, 7.5 kW 023 = 23 A–15 hp, 11 kW 031 = 31 A–20 hp, 15 kW 038 = 38 A–25 hp, 18.5 kW 046 = 46 A–30 hp, 22 kW 061 = 61 A–40 hp, 30 kW 072 = 72 A–50 hp, 37 kW 087 = 87 A–60 hp, 45 kW 105 = 105 A–75 hp, 55 kW 140 = 140 A–100 hp, 75 kW 170 = 170 A–125 hp, 90 kW 205 = 205 A–150 hp, 110 kW 261 = 261 A–200 hp, 132 kW 310 = 310 A–250 hp, 160 kW
3D9 = 3.9 A, 3 hp, 2.2 kW 6D1 = 6.1 A, 5 hp, 3.7 kW 9D0 = 9 A, 7.5 hp, 5.5 kW
011 = 11 A, 10 hp, 7.5 kW 01
8 = 18 A, 15 hp, 11 kW 022 = 22 A, 20 hp, 15 kW 027 = 27 A, 25 hp, 18 kW 034 = 34 A, 30 hp, 22 kW 041 = 41 A, 40 hp, 30 kW 052 = 52 A, 50 hp, 37 kW 062 = 62 A, 60 hp, 45 kW 080 = 80 A
, 75 hp, 55 kW
100 = 100 A, 100 hp, 75 kW 125 = 125 A, 125 hp, 90 kW 144 = 144 A, 150 hp, 110 kW 208 = 208 A, 200 hp, 160 kW
H-Max Series Drives
Adjustable Frequency Drives
H-Max Series Drives
2.8
2
Notes
Volume 6—Solid-State Motor Control CA08100007E—January 2017 V6-T2-171
2.8
NEMA Type 1
NEMA Type 12
Product Selection
H-Max Series Drives—230 Vac
2
Adjustable Frequency Drives
H-Max Series Drives
NEMA Type 1/IP21
FS Frame Size
4 3.7 0.75 0.55 3.2 2.6 HMX32AG3D721-N
5 18 5 4 15.2 12.5 HMX32AG01821-N
6 48 15 11 42 31 HMX32AG04821-N
775 25 18.5 68 62 HMX32AG07521-N
8 140 50 37 130 105 HMX32AG14021-N
9 261 100 75 248 205 HMX32AG26121-N
Drive Output Current Assigned Motor Ratings Low Overload Full
Load Amps at 40 °C Horsepower
4.8 1 0.75 4.2 3.7 HMX32AG4D821-N
6.6 1.5 1.1 6.6 4.8 HMX32AG6D621-N
8 2 1.5 6.8 6.6 HMX32AG8D021-N
11 3 2.2 9.6 8 HMX32AG01121-N
12.5 4 3 N/A 11 HMX32AG01221-N
24 7.5 5.5 22 18 HMX32AG02421-N
31 10 7.5 28 24 HMX32AG03121-N
62 20 15 54 48 HMX32AG06221-N
88 30 22 80 75 HMX32AG08821-N
105 40 30 104 88 HMX32AG10521-N
170 60 45 154 140 HMX32AG17021-N
205 75 55 192 170 HMX32AG20521-N
310 125 90 N/A 261 HMX32AG31021-N
Drive kW 230 Vac/50 Hz
230 Vac NEC Amps
Low Overload Full
1
Load Amps at 50 °C
Catalog Number
NEMA Type 12/IP54
FS Frame Size
4 3.7 0.75 0.55 3.2 2.6 HMX32AG3D722-N
5 18 5 4 15.2 12 HMX32AG01822-N
6 48 15 11 42 31 HMX32AG04822-N
775 25 18.5 68 62 HMX32AG07522-N
8 140 50 37 130 105 HMX32AG14022-N
9 261 100 75 248 205 HMX32AG26122-N
Note
1
For sizing reference.
Drive Output Current Assigned Motor Ratings Low Overload Full
Load Amps at 40 °C Horsepower
4.8 1 0.75 4.2 3.7 HMX32AG4D822-N
6.6 1.5 1.1 6.6 4.8 HMX32AG6D622-N
8 2 1.5 6.8 6.6 HMX32AG8D022-N
11 3 2.2 9.6 8 HMX32AG01122-N
12.5 4 3 N/A 11 HMX32AG01222-N
24 7.5 5.5 22 18 HMX32AG02422-N
31 10 7.5 28 24 HMX32AG03122-N
62 20 15 54 48 HMX32AG06222-N
88 30 22 80 75 HMX32AG08822-N
105 40 30 104 88 HMX32AG10522-N
170 60 45 154 140 HMX32AG17022-N
205 75 55 192 170 HMX32AG20522-N
310 125 90 N/A 261 HMX32AG31022-N
Drive kW 230 Vac/50 Hz
230 Vac NEC Amps
Low Overload Full
1
Load Amps at 50 °C
Catalog Number
V6-T2-172 Volume 6—Solid-State Motor Control CA08100007E—January 2017
H-Max Series Drives—480 Vac
NEMA Type 1
NEMA Type 12
Adjustable Frequency Drives
H-Max Series Drives
2.8
NEMA Type 1/IP21
FS Frame Size
4 3.4 1.5 1.1 2.1 2.6 HMX34AG3D421-N
5 16 10 7.5 14 12 HMX34AG01621-N
6 38 25 18.5 34 31 HMX34AG03821-N
7 72 50 37 65 61 HMX34AG07221-N
8 140 100 75 124 105 HMX34AG14021-N
9 261 200 132 240 205 HMX34AG26121-N
Drive Output Current Assigned Motor Ratings Low Overload Full
Load Amps at 40 °C Horsepower
4.8 2 1.5 3.4 3.4 HMX34AG4D821-N
5.6 3 2.2 5.6 4.8 HMX34AG5D621-N
8.0 4 3.0 N/A 5.6 HMX34AG8D021-N
9.6 5 4 7.6 8 HMX34AG9D621-N
12 7.5 5.5 11 9.6 HMX34AG01221-N
23 15 11 21 16 HMX34AG02321-N
31 20 15 27 23 HMX34AG03121-N
46 30 22 40 38 HMX34AG04621-N
61 40 30 52 46 HMX34AG06121-N
87 60 45 77 72 HMX34AG08721-N
105 75 55 96 87 HMX34AG10521-N
170 125 90 156 140 HMX34AG17021-N
205 150 110 180 170 HMX34AG20521-N
310 250 160 302 261 HMX34AG31021-N
Drive kW 400 Vac/50 Hz
480 Vac NEC Amps
Low Overload Full
1
Load Amps at 50 °C
Catalog Number
2
NEMA Type 12/IP54
FS Frame Size
4 3.4 1.5 1.1 2.1 2.6 HMX34AG3D422-N
5 16 10 7.5 14 12 HMX34AG01622-N
6 38 25 18.5 34 31 HMX34AG03822-N
7 72 50 37 65 61 HMX34AG07222-N
8 140 100 75 124 105 HMX34AG14022-N
9 261 200 132 240 205 HMX34AG26122-N
Note
1
For sizing reference.
Drive Output Current Assigned Motor Ratings Low Overload Full
Load Amps at 40 °C Horsepower
4.8 2 1.5 3.4 3.4 HMX34AG4D822-N
5.6 3 2.2 5.6 4.8 HMX34AG5D622-N
8.0 4 3.0 N/A 5.6 HMX34AG8D022-N
9.6 5 4 7.6 8 HMX34AG9D622-N
12 7.5 5.5 11 9.6 HMX34AG01222-N
23 15 11 21 16 HMX34AG02322-N
31 20 15 27 23 HMX34AG03122-N
46 30 22 40 38 HMX34AG04622-N
61 40 30 52 46 HMX34AG06122-N
87 60 45 77 72 HMX34AG08722-N
105 75 55 96 87 HMX34AG10522-N
170 125 90 156 140 HMX34AG17022-N
205 150 110 180 170 HMX34AG20522-N
310 250 160 302 261 HMX34AG31022-N
Drive kW 400 Vac/50 Hz
480 Vac
EC Amps
N
Low Overload Full
1
Load Amps at 50 °C
Catalog Number
Volume 6—Solid-State Motor Control CA08100007E—January 2017 V6-T2-173
Adjustable Frequency Drives
NEMA Type 1
NEMA Type 12
2.8
H-Max Series Drives—600 Vac
H-Max Series Drives
2
NEMA Type 1/IP21
FS Frame Size
5 3.9 3 2.2 4.6 3.3 HMX35AG3D921-N
618151119.915.3HMX35AG01821-N
741403045.334.9HMX35AG04121-N
88075559068HMX35AG08021-N
9 144 150 110 156 122.4 HMX35AG14421-N
Drive Output Current Assigned Motor Ratings Low Overload Full
Load Amps at 40 °C Horsepower
6.1 5 3.7 6.8 5.2 HMX35AG6D121-N
9 7.5 5.5 9 7.7 HMX35AG9D021-N
11 10 7.5 10.5 9.4 HMX35AG01121-N
22 20 15 23.3 18.7 HMX35AG02221-N
27 25 18 27.2 23 HMX35AG02721-N
34 30 22 32.8 28.9 HMX35AG03421-N
52 50 37 53.8 44.2 HMX35AG05221-N
62 60 45 62.2 52.7 HMX35AG06221-N
100 100 75 106 85 HMX35AG10021-N
125 125 90 127 106.3 HMX35AG12521-N
208 200 160 212 176.8 HMX35AG20821-N
Drive kW 575 Vac/50 Hz
575 Vac NEC Amps
Low Overload Full
1
Load Amps at 50 °C
Catalog Number
NEMA Type 12/IP54
FS Frame Size
5 3.9 3 2.2 4.6 3.3 HMX35AG3D922-N
618151119.915.3HMX35AG01822-N
741403045.334.9HMX35AG04122-N
88075559068HMX35AG08022-N
9 144 150 110 156 122.4 HMX35AG14422-N
Note
1
For sizing reference.
Drive Output Current Assigned Motor Ratings Low Overload Full
Load Amps at 40 °C Horsepower
6.1 5 3.7 6.8 5.2 HMX35AG6D122-N
9 7.5 5.5 9 7.7 HMX35AG9D022-N
11 10 7.5 10.5 9.4 HMX35AG01122-N
22 20 15 23.3 18.7 HMX35AG02222-N
27 25 18 27.2 23 HMX35AG02722-N
34 30 22 32.8 28.9 HMX35AG03422-N
52 50 37 53.8 44.2 HMX35AG05222-N
62 60 45 62.2 52.7 HMX35AG06222-N
100 100 75 106 85 HMX35AG10022-N
125 125 90 127 106.3 HMX35AG12522-N
208 200 160 212 176.8 HMX35AG20822-N
Drive kW 575 Vac/50 Hz
575 Vac NEC Amps
Low Overload Full
1
Load Amps at 50 °C
Catalog Number
V6-T2-174 Volume 6—Solid-State Motor Control CA08100007E—January 2017
Onboard Network Communications
Johnson Controls Metasys N2
H-Max Series provides communication between the drive and a Johnson Controls Metasys™ N2 network. With this connection, the drive can be controlled, monitored and programmed from the Metasys system. N2 can be selected and programmed by the drive keypad.
H-Max Series Option Board Kits Available for Slot B
The factory issued relay option board can be replaced with the following option
BACnet
H-Max Series provides communication to BACnet networks. Data transfer is master-slave/token passing (MS/TP) RS-485.
BACnet/IP
100Base-T interface.
Modbus TCP
Ethernet based protocol.
boards to customize the drive for your application needs.
Adjustable Frequency Drives
H-Max Series Drives
Modbus RTU
H-Max Series provides communication to Modbus RTU RS-485 as a slave on a Modbus network. Other communication parameters include an address range from 1–247; a parity of None, Odd or Even; and the stop bit is 1.
The standard board provides 2 Form C RO (NO/NC) and 1 Form A RO (NO).
2.8
2
Option Boards Mounted in Slot B
Option Kit Description
I/O expander card, 2 RO and thermistor input Relay Board 2
H-Max Series Option Board Kits Available for Slots D and E
The H-Max Series drives can accommodate a wide selection of expander and adapter option boards to customize the drive for your
Option Boards Mounted in Slots D and E
Option Kit Description
6 x DI /DO, each digital input can be individually programmed as digital output XMX-IO-B1-A
1RO Form C (NO/NC), 1RO Form A (NO), 1 thermistor XMX-IO-B2-A
1 x AI, 2 x AO (isolated) XMX-IO-B4-A
3 x RO Form A (NO) XMX-IO-B5-A
1RO Form A (NO), 5DI 42–240 Vac input XMX-IO-B9-A
1 x AO, 1 x DO, 1 x RO XMX-IO-BF-A
®
LonWorks
NEMA Type 1 to NEMA Type 12/IP54 Conversion Kit
The NEMA Type 12/IP54 option kit is used to convert a NEMA Type 1 to a NEMA Type 12 drive.
application needs. The drive’s control unit is designed to accept a total of two option boards.
Kit consists of a drive cover, fan kit and plugs.
Option Kit Catalog Number
The H-Max Series factory­installed standard board configuration includes an I/O board and a relay output board.
Option Kit Catalog Number
XMX-COM-C4-A
NEMA Type 12/IP54 Cover
Option Kit Description
FS4-branded N12/IP54 cover with gasket, plastic plug, fans, Eaton logos FS4-N12KIT
FS5-branded N12/IP54 cover with gasket, plastic plug, fans, Eaton logos FS5-N12KIT
FS6-branded N12/IP54 cover with gasket, plastic plug, fans, Eaton logos FS6-N12KIT
Volume 6—Solid-State Motor Control CA08100007E—January 2017 V6-T2-175
Option Kit Catalog Number
2.8
Adjustable Frequency Drives
H-Max Series Drives
Accessories
Flange Kits
2
The flange kit is used when the power section heat sink is mounted through the back panel of an enclosure.
Flange Kit NEMA Type 12/IP54
Includes flange, mounting brackets, NEMA Type 12 fan components, air shroud screws and plugs.
12
Frames FS4–FS7
Description
NEMA Type 12/IP54
FS4 N12/IP54 flange kit
(mounting N1 drive into N12 enclosure)
FS5 N12/IP54 flange kit
(mounting N1 drive into N12 enclosure)
FS6 N12/IP54 flange kit
(mounting N1 drive into N12 enclosure)
FS7 N12/IP54 flange kit
(mounting N1 drive into N12 enclosure)
Keypad Accessories
Remote Mounting Keypad Kit
Frames FS4–FS9
Description
Remote mounting keypad kit—bezel and cable OPTRMT-BP-HMAX-WLABL
Catalog Number
FS4-Flange-N12KIT
FS5-Flange-N12KIT
FS6-Flange-N12KIT
FS7-Flange-N12KIT
Catalog Number
Replacement Parts
Control Board/Keypad
Description
H-Max series graphic bypass, HOA KeypadbypassHOA
H-Max series graphic back, HOA KeypadbackHOA
H-Max control board replacement HMX-SPR-CTRLBOARD
PC Cable
Description
Remote download USB to RJ-45 cable with
software driver disk
Replacement Relay Board in Slot B
Description
Replacement relay board
qty 2 Form C relay, qty 1 Form A relay
Main Fan
Description
FS4 main fan FS4-Main Fan
FS5 main fan FS5-Main Fan
FS6 main fan FS6-Main Fan
FS7 main fan FS7-Main Fan
FS8 main fan FS8-Main Fan
FS9 main fan FS9-Main Fan
Current Catalog Number
Catalog Number
REM-USB-Down
Catalog Number
Relay board 1
Catalog Number
Drive Demo
H-Max Series Drive Demo
Demos and Power Supply
Description
H-Max Series bypass demo H-MAX-BYPASS-DEMO
Hand-held 24 V auxiliary power supply—used to supply power to the control module in order to perform keypad programming before the drive is connected to line voltage
Notes
1
For installation of a NEMA Type 1 drive into a NEMA Type 12 oversized enclosure.
2
Frame size 8 and 9 must be ordered from the factory as a flange mount unit.
Catalog Number
9000XAUX24 V
Internal Fan
Description
FS4 internal fan (IP54/NEMA 12) FS4-Internal Fan
FS5 internal fan (IP54/NEMA 12) FS5-Internal Fan
FS6 internal fan (IP54/NEMA 12) FS6-Internal Fan
FS7 internal fan (IP54/NEMA 12) FS7-Internal Fan
FS8 internal fan (IP54/NEMA 12) FS8-Internal Fan
FS9 internal fan (IP54/NEMA 12) FS9-Internal Fan
Catalog Number
V6-T2-176 Volume 6—Solid-State Motor Control CA08100007E—January 2017
Line and Load Reactors
A line and load reactor is a three-phase inductance filter that can be placed on the line and load side of the AFD to help improve the harmonic performance of the system. Consult the factory for additional filtering options and further technical details.
DR1 Line Reactor
A line reactor helps to provide a moderate reduction in current harmonics similar to a DC choke. It also provides increased input protection for AFD and its semiconductors from line transients helping to extend the life of the AFD.
Line and Load Reactors—Catalog Number Selection
D R1 –22D0 –05
Adjustable Frequency Drives
H-Max Series Drives
DR2 Output Reactor
An output filter is used to reduce the transient voltage (dV/dt) at the motor terminals. The output filter is recommended for cable lengths exceeding 100 ft (30 m) with a drive of 3 hp and above and for cable lengths of 33 ft (10 m) with a drive of 2 hp and below.
2.8
2
Basic Naming
D = Drive
Device Series
R1 = Line side reactor R2 = Load side reactor
Input/Output Voltage
2 = 240 V 4 = 480 V
Current Rating
Examples:
2D0 = 2.0 A 4D0 = 4.0 A 8D0 = 8.0 A
012
= 12 A
Impedance
3 = 3% 5 = 5%
Environment Rating
0 = Open 1 = NEMA 1
Line and Load Reactors—240 V
Open NEMA 1 Load Reactor Line Reactor Load Reactor Line Reactor
hp (VT) 3% 5% 3% 5% 3% 5% 3% 5%
0.75 DR2-24D0-03 DR2-24D0-05 DR1-23D2-03 DR1-23D2-05 DR2-24D0-13 DR2-24D0-15 DR1-23D2-13 DR1-23D2-15
1 DR2-24D0-03 DR2-28D0-05 DR1-24D2-03 DR1-24D2-05 DR2-24D0-13 DR2-28D0-15 DR1-24D2-13 DR1-24D2-15
1.5 DR2-28D0-03 DR2-28D0-05 DR1-26D0-03 DR1-26D0-05 DR2-28D0-13 DR2-28D0-15 DR1-26D0-13 DR1-26D0-15
2 DR2-28D0-03 DR2-28D0-05 DR1-26D8-03 DR1-26D8-05 DR2-28D0-13 DR2-28D0-15 DR1-26D8-13 DR1-26D8-15
3 DR2-2012-03 DR2-2012-05 DR1-29D6-03 DR1-29D6-05 DR2-2012-13 DR2-2012-15 DR1-29D6-13 DR1-29D6-15
5 DR2-2018-03 DR2-2018-05 DR1-2015-03 DR1-2015-05 DR2-2018-13 DR2-2018-15 DR1-2015-13 DR1-2015-15
7.5 DR2-2025-03 DR2-2025-05 DR1-2022-03 DR1-2022-05 DR2-2025-13 DR2-2025-15 DR1-2022-13 DR1-2022-15
10 DR2-2035-03 DR2-2035-05 DR1-2028-03 DR1-2028-05 DR2-2035-13 DR2-2035-15 DR1-2028-13 DR1-2028-15
15 DR2-2045-03 DR2-2045-05 DR1-2042-03 DR1-2042-05 DR2-2045-13 DR2-2045-15 DR1-2042-13 DR1-2042-15
20 DR2-2055-03 DR2-2055-05 DR1-2054-03 DR1-2054-05 DR2-2055-13 DR2-2055-15 DR1-2054-13 DR1-2054-15
25 DR2-2080-03 DR2-2080-05 DR1-2068-03 DR1-2068-05 DR2-2080-13 DR2-2080-15 DR1-2068-13 DR1-2068-15
30 DR2-2080-03 DR2-2100-05 DR1-2080-03 DR1-2080-05 DR2-2080-13 DR2-2100-15 DR1-2080-13 DR1-2080-15
40 DR2-2100-03 DR2-2100-05 DR1-2104-03 DR1-2104-05 DR2-2100-13 DR2-2100-15 DR1-2104-13 DR1-2104-15
50 DR2-2130-03 DR2-2130-05 DR1-2130-03 DR1-2130-05 DR2-2130-13 DR2-2130-15 DR1-2130-13 DR1-2130-15
60 DR2-2160-03 DR2-2200-15 DR1-2154-03 DR1-2154-05 DR2-2160-13 DR2-2200-15 DR1-2154-13 DR1-2154-15
75 DR2-2200-13 DR2-2200-15 DR1-2192-03 DR1-2192-05 DR2-2200-13 DR2-2200-15 DR1-2192-13 DR1-2192-15
100 DR2-2225-13 DR2-2225-15 DR1-2248-03 DR1-2248-05 DR2-2225-13 DR2-2225-15 DR1-2248-13 DR1-2248-15
125 DR2-2320-13 DR2-2320-15 DR1-2312-03 DR1-2312-05 DR2-2320-13 DR2-2320-15 DR1-2312-13 DR1-2312-15
Volume 6—Solid-State Motor Control CA08100007E—January 2017 V6-T2-177
Adjustable Frequency Drives
2.8
Line and Load Reactors—480 V
Open NEMA 1
2
hp (VT) 3% 5% 3% 5% 3% 5% 3% 5%
1.5 DR2-44D0-05 DR2-44D0-05 DR1-43D0-03 DR1-43D0-05 DR2-44D0-13 DR2-44D0-15 DR1-43D0-13 DR1-43D0-15
2 DR2-44D0-03 DR2-44D0-05 DR1-43D4-03 DR1-43D4-05 DR2-44D0-13 DR2-44D0-15 DR1-43D4-13 DR1-43D4-15
3 DR2-48D0-03 DR2-48D0-05 DR1-44D8-03 DR1-44D8-05 DR2-48D0-13 DR2-48D0-15 DR1-44D8-13 DR1-44D8-15
5 DR2-48D0-03 DR2-48D0-05 DR1-47D6-03 DR1-47D6-05 DR2-48D0-13 DR2-48D0-15 DR1-47D6-13 DR1-47D6-15
7.5 DR2-4012-03 DR2-4012-05 DR1-4011-03 DR1-4011-05 DR2-4012-13 DR2-4012-15 DR1-4011-13 DR1-4011-15
10 DR2-4018-03 DR2-4018-05 DR1-4014-03 DR1-4014-05 DR2-4018-13 DR2-4018-15 DR1-4014-13 DR1-4014-15
15 DR2-4025-03 DR2-4025-05 DR1-4021-03 DR1-4021-05 DR2-4025-13 DR2-4025-15 DR1-4021-13 DR1-4021-15
20 DR2-4025-03 DR2-4025-05 DR1-4027-03 DR1-4027-05 DR2-4025-13 DR2-4025-15 DR1-4027-13 DR1-4027-15
25 DR2-4035-03 DR2-4035-05 DR1-4034-03 DR1-4034-05 DR2-4035-13 DR2-4035-15 DR1-4034-13 DR1-4034-15
30 DR2-4045-03 DR2-4045-05 DR1-4040-03 DR1-4040-05 DR2-4045-13 DR2-4045-15 DR1-4040-13 DR1-4040-15
40 DR2-4055-03 DR2-4055-05 DR1-4052-03 DR1-4052-05 DR2-4055-13 DR2-4055-15 DR1-4052-13 DR1-4052-15
50 DR2-4080-03 DR2-4080-05 DR1-4065-03 DR1-4065-05 DR2-4080-13 DR2-4080-15 DR1-4065-13 DR1-4065-15
60 DR2-4100-03 DR2-4080-05 DR1-4077-03 DR1-4077-05 DR2-4100-13 DR2-4080-15 DR1-4077-13 DR1-4077-15
75 DR2-4100-03 DR2-4100-05 DR1-4096-03 DR1-4096-05 DR2-4100-13 DR2-4100-15 DR1-4096-13 DR1-4096-15
100 DR2-4130-03 DR2-4130-05 DR1-4124-03 DR1-4124-05 DR2-4130-13 DR2-4130-15 DR1-4124-13 DR1-4124-15
125 DR2-4160-03 DR2-4160-05 DR1-4156-03 DR1-4156-05 DR2-4160-13 DR2-4160-15 DR1-4156-13 DR1-4156-15
150 DR2-4200-13 DR2-4200-15 DR1-4180-03 DR1-4180-05 DR2-4200-13 DR2-4200-15 DR1-4180-13 DR1-4180-15
200 DR2-4250-13 DR2-4250-15 DR1-4240-03 DR1-4240-05 DR2-4250-13 DR2-4250-15 DR1-4240-13 DR1-4240-15
Load Reactor Line Reactor Load Reactor Line Reactor
H-Max Series Drives
V6-T2-178 Volume 6—Solid-State Motor Control CA08100007E—January 2017
Technical Data and Specifications
Adjustable Frequency Drives
H-Max Series Drives
2.8
H-Max Series Drives
Description Specification
Input Ratings
Input voltage (V
Input frequency (f
Connection to power Once per minute or less (typical operation)
Short-circuit withstand rating
Output Ratings
Output voltage 0 to V
Continuous output current Ambient temperature max. 104 °F (40 °C)
overload 1.1 x IL (1 min./10 min.)
I
L
Overload current 110% (1 min./10 min.)
Initial output current 150% for two seconds
Output frequency 0 to 320 Hz
Frequency resolution 0.01 Hz
Control Characteristics
Control method Frequency control (V/f) open loop sensorless vector control
Switching frequency 1–310 amps
Frequency reference Analog input: Resolution 0.1% (10-bit), accuracy ±1%
Field weakening point 8 to 320 Hz
Acceleration time 0.1 to 3000 seconds
Deceleration time 0.1 to 3000 seconds
Braking torque DC brake: 30% x T
Ambient Conditions
Ambient operating temperature
Storage temperature –40° to 158 °F (–40° to 70 °C)
Relative humidity 0 to 95% RH, noncondensing, non-corrosive, no dripping water
Air quality Chemical vapors: IEC 60721-3-3, unit in operation, Class 3C2;
Altitude 100% load capacity (no derating) up to 3280 ft (1000 m);
Vibration FS4–FS9: EN 61800-5-1, EN 60068-2-6; 5 to 150 Hz,
Shock EN 61800-5-1, EN 60068-2-27 UPS Drop test (for applicable UPS
Enclosure class NEMA Type 1/IP21 or NEMA Type 12/IP54
Standards
EMC Immunity: Fulfills all EMC immunity requirements;
Emissions EMC level dependent—
Efficiency 97.5% at 480 V
) 200–240 Vac, 380–480 Vac, 525–600 Vac, –10%/+10%
in
) 50/60 Hz (variation up to 47–66 Hz)
in
100 kAIC
line voltage in
in/Uin
FS4–9: default 6 kHz
Panel reference: Resolution 0.01 Hz
n
FS4–FS9: 14 °F (–10 °C), no frost to 104 °F (40 °C) (Drive can operate at 122 °F (50 °C), see Pages V6-T2-172 and V6-T2-173)
Mechanical particles: IEC 60721-3-3, unit in operation, Class 3S2
1% derating for each 328 ft (100 m) above 3280 ft (1000 m); max. 9842 ft (3000 m); 380–480 V
displacement amplitude 1 mm (peak) at 5 to 15.8 Hz, max. acceleration amplitude 1G at 15.8 to 150 Hz
weights) Storage and shipping: max. 15 g, 11 ms (in package)
(keypad required for IP54/Type 12)
Emissions: EN 61800-3, LEVEL H (EMC C2)
+EMC 2: EN61800-3 (2004) Category C2 Delivered with Class C2 EMC filtering as default.
96.6% at 208/230 V
Description Specification
Control Connections
Analog input voltage 0 to 10 V, R = 200 kohms differential
Analog input current 0(4) to 20 mA; R
Digital inputs (6) Positive or negative logic; 18 to 30 Vdc
Auxiliary voltage +24 V ±10%, max. 250 mA
Output reference voltage +10 V +3%, max. load 10 mA
Analog output 0–10 V, 0(4) to 20 mA; R
Relay outputs 3 programmable, 2 Form C, 1 Form A relay outputs
Hard wire jumper Between terminal 6 and 10 factory default
DIP switch setting default RS-485 = off
Resolution 0.1%; Accuracy ±1% DIP switch selection (voltage/current)
–250 ohms differential
i
max. 500 ohms; Resolution 10 bit; Accuracy ±2% DIP switch selection (voltage/current)
Switching capacity: 24 Vdc/8 A, 250 Vac/8 A, 125 Vdc/0.4 A
A01 = current A12 = current A11 = voltage
L
Protections
Overcurrent protection Yes
Overvoltage protection Yes
DC bus regulation anti-trip Yes (accelerates or decelerates the load)
Undervoltage protection Yes
Earth fault protection Yes (in case of earth fault in motor or motor cable,
Input phase supervision Yes (trips if any of the input phases are missing)
Motor phase supervision Yes (trips if any of the output phases are missing)
Overtemperature protection Yes
Motor overload protection Yes
Motor stall protection Yes
Motor underload protection Yes
Short-circuit protection Yes
Surge protection Yes (varistor input)
Conformed coated (varnished) boards
only the frequency converter is protected)
Yes (prevents corrosion)
2
Volume 6—Solid-State Motor Control CA08100007E—January 2017 V6-T2-179
Adjustable Frequency Drives
Slot A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
A
+10V
AI–1+
V
in
AI–2+
AI–2–
24V
out
GND
DIN1
DIN2
DIN3
24V
out
GND
DIN4
DIN5
DIN6
AO–1+
AO–1–
DATA -
Reference Output Analog Input Voltage (Range 0–10 Vdc)
(can be programmed to current 4–20 mA) Analog Output Common (Ground)
Analog Input Common PI Setpoint or Feedback
Control Voltage Output (250 A max.)
I/O Ground
START/STOP (Contact closed = start)
External Fault (Closed = fault) Run Interlock Permissive IP Interlock
(Closed = OK) DIN1–DIN6 Common
Control Voltage Output (250 A max.)
I/O Ground
Fire Mode (Contact closed = re mode)
Force Bypass (Contact closed = bypass)
DIN1–DIN6 Common
Output Frequency (0–20 mA)
Analog Output Common (Ground)
RS-485 DATA-
Speed Select 0–100% (Preset speed)
U (T1)
V (T2)
W (T3)
R+
R-
L1
L2
L3
Three-Phase Input Input (Single-Phase not available)
Three-Phase
Output
DB
Chopper
Optional Resistor
Terminal
Factory Default Signal
Resistor
Analog Input Current (Range 4–20 mA) (can be programmed to voltage 0–10 Vdc) PI Setpoint or Feedback
B
DATA +
RO1 Bypass Run
RO2 Drive Run
RO3 Fault
24 Vdc/8A 250 Vac/8A 125 Vdc/0.4A
Relay Board 1 Default Signal
21
22
23
24
25
26
32
33
Slot B
Analog
RS-485 DATA+
Factory Jumper
COM
CMB
30
24 VdcinAuxiliary Input Voltage
12345678 91011
12 13 14 15 16 17 18 19 30 A B
RS-485
Data–
RS-485
Data+
24 Vdc
in
AO1–AO1+COM
DI1–6
DI6DI5DI4GND24 Vdc
out
DI2DI1GND24 Vdc
out
AI2–AI2+AI1–AI1++10
Vdc
COM
DI1–6
DI3
21
RO1
22 23 24 25 26 32 33
NC
RO1
COM
RO1
NO
RO2NCRO2
COM
RO2
NO
RO3
COM
RO3
NO
Slot D __________________
Slot E __________________
Terminal Block Layout
Factory Jumper External Interlock
Circuit Breaker
Optional
Motor
RJ-45
BACnet/IP Ethernet Industrial Protocol Modbus/TCP Transmission Control Protocol (Ethernet Based)
5% DC Link Reactor
Programmable BACnet, Modbus, N2
ON CURRENT CURRENT CURRENT
RS485 AO1 AI2 AI1
OFF VOLTAGE VOLTAGE VOLTAGE
Test
Note: The terminal block layout for the 525–600 V rated drives is different. Please refer to manual MN040021EN.
2.8
Wiring Diagram
Control Input/Output, PID Application
2
H-Max Series Drives
Standards
Digital inputs D1–D6, relay out, analog in/out are freely programmed
The user can assign a single input to multiple functions
V6-T2-180 Volume 6—Solid-State Motor Control CA08100007E—January 2017
Includes
Six digital input Two analog input One analog output Three relay output RS-485 Ethernet (BACnet and
Modbus)
Reliability
Pretested components
Conformal coated (varnished) boards
40 °C rated
110% overload for one minute
Eaton Electrical Services & Systems national network of AF drive specialists
Loading...
+ 23 hidden pages