The CurrentWatch EGF Series from
Eaton’s electrical business is a family
of ground fault (earth leakage) sensors.
Ground fault sensors help protect
people, products and processes from
damage by ground fault conditions
by monitoring all current-carrying
conductors in grounded single- and
three-phase delta or wye systems.
The EGF Series is available with
either solid-state or mechanical relay
outputs.
The EGF Series with solid-state outputs offers the benefit of reliable,
long-lasting solid-state switches.
Solid-state design provides unlimited switch operating life, superior
resistance to shock and vibration,
zero off-state leakage, high switch
speeds and high input-output isolation. Solid-state outputs have solidcore housings with screw terminals.
The EGF Series with mechanical
relay outputs are available in solidcore housings with a choice of N.O. or
N.C. SPST latching relays and a SPDT
Form C relay with auto-reset. All
mechanical models can be ordered
with a fixed setpoint or with a “triset” option, which provides three
factory-set, field-adjustable setpoints.
Approvals
■
UL Recognized
Unless otherwise noted, the
products contained in this
document are not designed
or intended for use in human
safety applications.
CurrentWatch™ Current Sensors
EGF Series Ground Fault Sensors
CA05311002E
Ground Fault Sensors with Solid-State or Mechanical Relay
Outputs
Product Features
■
Broad Range of Options to Meet Application Needs — N.O. or N.C., solid-
state or mechanical relays, normally energized or normally de-energized
contacts
■
Setpoint Options Maximize Ease-of-Use and Application Flexibility — Field
selectable 5, 10 or 30 mA setpoints on the EGF “Tri-set” models make user
adjustments fast, sure and convenient
Compatible with Standard Equipment — Application on single- and three-
■
phases systems, ideal for use with shunt trip breakers, and magnetically
isolated from monitored circuit and control power
■
Agency Approved — UL and CE Certified, accepted worldwide
ditions, which could cause injury to people, and functions as a sensor and
alarm trigger when applied as an input to an overall ground fault protection
system
Equipment Protection (Typically 10 or 30 mA) — For applications where
■
personnel protection is not the primary concern, higher setpoint capability
helps eliminate nuisance tripping while still providing adequate ground
fault detection to protect machine electronics
Regulatory — Meets requirements as stipulated by governmental and
■
industrial regulatory groups for ground fault sensing
”Zero Sequence” Operating Principle
In three-phase delta and wye systems, under normal conditions, current in the
“hot” leg of a two-wire load is equal in magnitude but opposite in sign to the
current in a neutral leg. As a result, the electromagnetic fields surrounding these
two conductors cancel, producing a “zero sum current.” As soon as current leaks
to ground (fault condition), the two currents become imbalanced and a net
magnetic field results. The CurrentWatch EGF Series sensors monitor this field
and trips the contacts when the leakage rises above the setpoint.
1
For Customer Service in the U.S. call 1-877-ETN CARE (386-2273),
in Canada call 1-800-268-3578.
For Application Assistance in the U.S. and Canada
call 1-800-426-9184.
CA05311002EFor more information visit: www.eaton.com
CurrentWatch™ Current Sensors
2
EGF Series Ground Fault Sensors
Example Application — CurrentWatch EGF Series
Insulation Breakdown Monitoring
February 2009
Ground Fault Sensor
Circuit Interruption Device
E.g. Contactor
Model Selection — CurrentWatch EGF Series
Power SupplySetpointAC Solid-State
Solid-State Output Sensors
Solid-Core Housings
Stocked product, typical order quantities guaranteed in stock.
120V ACFixed, 50 mASolid-State, N.O.,
Fixed, 100 mASolid-State, N.O.,
Tri-Set Adjustable,
5, 10 or 30 mA
Leakage
to Ground
Output
1A @ 240V AC
Solid-State, N.C.,
1A @ 240V AC
—Solid-State, N.O.,
—Solid-State, N.C.,
1A @ 240V AC
Solid-State, N.C.,
1A @ 240V AC
—Solid-State, N.O.,
—Solid-State, N.C.,
Solid-State, N.O.,
1A @ 240V AC
Solid-State, N.C.,
1A @ 240V AC
—Solid-State, N.O.,
—Solid-State, N.C.,
DC Solid-State
Output
—Normally Energized
—Normally Energized
0.15A @ 30V DC
0.15A @ 30V DC
—Normally Energized
—Normally Energized
0.15A @ 30V DC
0.15A @ 30V DC
—Normally Energized
—Normally Energized
0.15A @ 30V DC
0.15A @ 30V DC
ContactsCatalog Number
EGF1NOACNE050
Normally De-energizedEGF1NOACDE050
EGF1NCACNE050
Normally De-energizedEGF1NCACDE050
Normally Energized
Normally De-energizedEGF1NODCDE050
Normally Energized
Normally De-energizedEGF1NCDCDE050
Normally De-energizedEGF1NOACDE100
Normally De-energizedEGF1NCACDE100
Normally Energized
Normally De-energizedEGF1NODCDE100
Normally Energized
Normally De-energizedEGF1NCDCDE100
Normally De-energizedEGF3NOACDET3
Normally De-energizedEGF3NCACDET3
Normally Energized
Normally De-energizedEGF3NODCDET3
Normally Energized
Normally De-energizedEGF3NCDCDET3
EGF1NODCNE050
EGF1NCDCNE050
EGF1NOACNE100
EGF1NCACNE100
EGF1NODCNE100
EGF1NCDCNE100
EGF3NOACNET3
EGF3NCACNET3
EGF3NODCNET3
EGF3NCDCNET3
For more information visit: www.eaton.com
CA05311002E
CurrentWatch™ Current Sensors
EGF Series Ground Fault Sensors
February 2009
Model Selection — CurrentWatch EGF Series (Continued)
Power SupplySetpointMechanical Relay OutputContactsCatalog Number
Mechanical Relay Output Sensors
Solid-Core Housings
Stocked product, typical order quantities guaranteed in stock.
120V ACFixed, 50 mAMechanical Relay, N.O. SPST Relay, Form A
Fixed, 100 mAMechanical Relay, N.O. SPST Relay, Form A
Tri-set Adjustable,
5, 10 or 30 mA
24V AC/DCFixed, 50 mAMechanical Relay, N.O. SPST Relay, Form A
Fixed, 100 mAMechanical Relay, N.O. SPST Relay, Form A
Tri-set Adjustable,
5, 10 or 30 mA
(1A @ 120V AC)
Mechanical Relay, N.C. SPST Relay, Form B
(1A @ 120V AC)
Mechanical Relay, SPDT Form C, Auto-Reset
(1A @ 120V AC)
(1A @ 120V AC)
Mechanical Relay, N.C. SPST Relay, Form B
(1A @ 120V AC)
Mechanical Relay, SPDT Form C, Auto-Reset
(1A @ 120V AC)
Mechanical Relay, N.O. SPST Relay, Form A
(1A @ 120V AC)
Mechanical Relay, N.C. SPST Relay, Form B
(1A @ 120V AC)
Mechanical Relay, SPDT Form C, Auto-Reset
(1A @ 120V AC)
(2A @ 30V DC)
Mechanical Relay, N.C. SPST Relay, Form B
(2A @ 30V DC)
Mechanical Relay, SPDT Form C, Auto-Reset
(2A @ 30V DC)
(2A @ 30V DC)
Mechanical Relay, N.C. SPST Relay, Form B
(2A @ 30V DC)
Mechanical Relay, SPDT Form C, Auto-Reset
(2A @ 30V DC)
Mechanical Relay, N.O. SPST Relay, Form A
(2A @ 30V DC)
Mechanical Relay, N.C. SPST Relay, Form B
(2A @ 30V DC)
Mechanical Relay, SPDT Form C, Auto-Reset
(2A @ 30V DC)
Latching Relay
Latching Relay
Normally Energized
Normally De-energizedEGF1SPDTDE050
Latching Relay
Latching Relay
Normally Energized
Normally De-energizedEGF1SPDTDE100
Latching Relay
Latching Relay
Normally Energized
Normally De-energizedEGF1SPDTDET3
Latching Relay
Latching Relay
Normally Energized
Normally De-energizedEGF2SPDTDE050
Latching Relay
Latching Relay
Normally Energized
Normally De-energizedEGF2SPDTDE100
Latching Relay
Latching Relay
Normally Energized
Normally De-energizedEGF2SPDTDET3
EGF1NOLA050
EGF1NCLA050
EGF1SPDTNE050
EGF1NOLA100
EGF1NCLA100
EGF1SPDTNE100
EGF1NOLAT3
EGF1NCLAT3
EGF1SPDTNET3
EGF2NOLA050
EGF2NCLA050
EGF2SPDTNE050
EGF2NOLA100
EGF2NCLA100
EGF2SPDTNE100
EGF2NOLAT3
EGF2NCLAT3
EGF2SPDTNET3
3
Accessories — CurrentWatch EGF Series
DescriptionCatalog Number
DIN Rail Mounting Kit (Sensor pictured
for reference and not included in kit)
Stocked product, typical order quantities guaranteed in stock.
CA05311002EFor more information visit: www.eaton.com
EDINKIT
Loading...
+ 4 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.