Cutler Hammer, Div of Eaton Corp DH1 Product Flyer

PowerXL series
DH1 HVAC/R drives
Next-generation drives for today’s demands
The DH1 HVAC/R drives are part of the Eaton next generation PowerXLE series of variable frequency drives specifically engineered to exceed the demands of the HVAC/R market. With an industry-leading energy efficiency algorithm, high short-circuit current rating and robust design, the DH1 offers customers increased efficiency, safety and reliability.
Graphic LCD keypad display
Active Energy ControlT algorithm
On-board communications:
ModbusT/TCP
Modbus RTU
BACnetT MS/TP
BACnet/IP
Onboard I/O:
8DI, 1DO
2AI, 2AO
2 FC relays and 1 FA relay
Real-time clock with battery backup
5% DC link choke
Standard applications:
Basic
Multi-PID
Multi-purpose
Advanced configuration PC tool
Benets
Variable torque rated for HVAC/R applications
Easy menu navigation
Two configurable keypad soft keys
Conformal coated boards standard
Product range
208–240 V, 1–125 hp, 312 A, 90 kW
380–500 V, 1.5–250 hp, 310 A, 160 kW
525–600 V, 3–250 hp, 250 A, 160 kW
Type 1/IP21 or Type 12/IP54 packaging
Catalog numbering system
Series Power part Options
D H1 – 3 4 011 D N – C 21 C
Basic naming
D = Drive
Series
H1 = HVAC
Phase reference
3 = 3~ input /3~output
Input/output voltage
2 = 230 V (208–240 V, –15%, +10%) 4 = 400 V (380–500 V, –15%, +10%) 5 = 600 V (252–600 V, –15%, +10%)
208–240 V 380–500 V 525–600 V
4D8 = 4.8 A, 1.0 hp, 0.75 kW 6D6 = 6.6 A, 1.5 hp, 1.1 kW 7D8 = 7.8 A, 2.0 hp, 1.5 kW 011 = 11 A, 3.0 hp, 2.2 kW 012 =12.5 A, 4.0 hp, 3.0 kW 017 = 17.5 A, 5.0 hp, 3.7 kW 025 = 25 A, 7.5 hp, 5.5 kW 031 = 31 A, 10 hp, 7.5 kW 048 = 48 A, 15 hp, 11 kW 061 = 61 A, 20 hp, 15 kW 075 = 75 A, 25 hp, 18.5 kW 088 = 88 A, 30 hp, 22 kW 114 = 114 A , 40 hp, 30 kW 143 = 143 A, 50 hp, 37 kW 170 = 170 A, 60 hp, 45 kW 211 = 211 A, 75 hp, 55 kW 261 = 261 A, 100 hp, 75 kW 312 = 312 A, 125 hp, 90 kW
Output current rating (VT)
3D3 = 3.3 A, 1.5 hp, 1.1 kW 4D3 = 4.3 A, 2.0 hp, 1.5 kW 5D6 = 5.6, 3.0 hp, 2.2 kW 7D6 = 7.6 A, 4.0 hp, 3 kW 9D0 = 9 A, 5.0 hp, 4 kW 012 = 12 A, 7.5 hp, 5.5 kW 016 = 16 A, 10 hp, 7.5 kW 023 = 23 A, 15 hp, 11 kW 031 = 31 A, 20 hp, 15 kW 038 = 38 A, 25 hp, 18.5 kW 046 = 46 A, 30 hp, 22 kW 061 = 61 A, 40 hp, 30 kW 072 = 72 A, 50 hp, 37 kW 087 = 87 A, 60 hp, 45 kW 105 = 105 A, 75 hp, 55 kW 140 = 140 A, 100 hp, 75 kW 170 = 170 A, 125 hp, 90 kW 205 = 205 A, 150 hp, 110 kW 261 = 261 A, 200 hp, 132 kW 310 = 310 A, 250 hp, 160 kW
Frames and power ranges
Frame size Voltage hp (V T/IL) kW Amperes (VT/IL)
FR0 230 Vac 1–2 0.75–1.5 4.8–7.8
480 Vac 1.5–5 1.1–3 3.3–7.6
FR1 230 Vac 1–4 0.75–3 4.8-12.5
480 Vac 1.5–7.5 1.1–5.5 3.3–12 575 Vac 3–7.5 2.2–5.5 4.5–10
FR2 230 Vac 5–10 3.7–7.5 17.5–31
480 Vac 10–20 7.5–15 16–31 575 Vac 10–20 7.5–15 13.5–22
FR3 230 Vac 15–20 11–15 48–61
480 Vac 25–40 18.5–30 38–61 575 Vac 25–40 18.5–30 27–41
FR4 230 Vac 25–40 18.5–30 75–114
480 Vac 50–75 37–55 72–105 575 Vac 50–75 37–55 52–80
FR5 230 Vac 50–75 37–55 143–211
480 Vac 100–150 75–110 140–205 575 Vac 100–150 75–110 100–144
FR6 230 Vac 100–125 75–90 261–312
480 Vac 200–250 132–160 261–310 575 Vac 200–250 150–187 208–250
Coating of boards
C = Coated
Enclosure (IP rating)
20 = IP20 (FR0 only)
4D5 = 4.5 A, 3 hp, 2.2 kW 7D5 = 7.5 A, 5.0 hp, 3.7 kW 010 = 10 A, 7.5 hp, 5.5 kW 013 = 13.5 A, 10 hp, 7.5 kW 018 = 18 A, 15 hp, 11 kW 022 = 22 A, 20 hp, 15 kW
21 = IP21/Type 1 54 = IP54/Type 12
Display option
C = LCD (graphical) W = No display
027 = 27 A, 25 hp, 18.5 kW 034 = 34 A, 30 hp, 22 kW 041 = 41 A, 40 hp, 30 kW 052 = 52 A, 50 hp, 37 kW 062 = 62 A, 60 hp, 45 kW 080 = 80 A, 75 hp, 55 kW 100 = 100 A, 100 hp, 75 kW 125 = 125 A, 125 hp, 90 kW 144 = 144 A, 150 hp, 110 kW 208 = 208 A, 200 hp, 150 kW 250 = 250 A, 250 hp, 187 kW
Internal brake chopper
N = No brake chopper B = Brake chopper
Internal EMC filter
D = DC choke only E = EMC filter only F = Internal EMC filter and DC choke N = No EMC filter, no DC choke
Input ratings
Description Specification
Input voltage (Bin) 208–240 V, 380–500 V, 525–600 V, –15 to 10% Input frequency (fin) 50–60 Hz (variation up to 45–66 Hz) Connection to power Up to one connection every 60 seconds Short-circuit withstand rating 100 kAIC (with fuses and circuit breakers)
Output ratings
Description Specification
Output voltage 0 to Vin VT/IL overload Overload 1.1 x IL (1 min./10 min.) Initial output current 200% (2 sec./20 sec.) Output frequency 0–400 Hz (standard) Frequency resolution 0.01 Hz
Ambient conditions
Description Specification
Operating temperature –10 ° C (no frost) to +50 ° C, up to +60 ° C
withderating Storage temperature –40 °C to +70 ° C Relative humidity 0–95% RH, noncondensing, non-corrosive Altitude 100% load capacity (no derating) up to
3280 ft (1000 m); 1% derating for each
328 ft (100 m) above 3280 ft (1000 m)
9843 ft (3000 m) maximum
Eaton
1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com
© 2018 Eaton All Rights Reserved Printed in USA Publication No. PA040023EN / Z20482 February 2018
Eaton is a registered trademark.
All other trademarks are property of their respective owners.
Follow us on social media to get the latest product and support information.
Loading...