Circuit Breakers & Supplementary Protectors 125 – 600 Amperes
August 2006
L-Frame
45
L-Frame
Product Description
All Cutler-Hammer L-Frame Circuit
Breakers by Eaton Corporation are HACR rated.
L-Frame circuit breakers are available
as individual components (Frame, Trip Unit, Terminals), or factory assembled complete breakers.
L-Frame circuit breakers with
non-interchangeable trip units are suitable for reverse feed use.
CE marked.
Technical Data and Specifications
I
cu
45 45 45 70
70 100 100
35 35 35 65 65
100 100
25 25 25 35 35
50 50
I
45 45 45 70
70 75 75
I
cs
cu
20 20 20 25
25 35 35
— — — — —
— —
I
cs
10 10 10 13
13 18 18
22 22 — 25 —
30 —

I
cu
20 20 — 20
— 20 —
Table 45-144. UL 489 Interrupting Capacity Ratings
Circuit Breaker Type
LDB LD CLD HLD, HLDB CHLD
LDC, LDCB CLDC
Utilization category A circuit breakers.
L/R = 8 milliseconds minimum.
2-pole circuit breaker or two poles of 3-pole circuit breaker. Incorporating Thermal-Magnetic trip unit only.
100% rated breakers.
Current limiting.

Number of Poles
2, 3 2, 3, 4 2, 3, 4 2, 3, 4 2, 3, 4
2, 3, 4 2, 3, 4
Interrupting Capacity (kA rms Symmetrical Amperes)
Volts ac (50/60 Hz) Volts dc
240 277 480 600 125 250
65 65 65 100 100
200 200
— — — — —
— —
Table 45-145. IEC 947-2 Interrupting Capacity Ratings
Circuit Breaker Type
LDB LD
CLD HLD, HLDB
CHLD LDC, LDCB CLDC
Utilization category A circuit breakers.
L/R = 8 milliseconds minimum.
2-pole circuit breaker or two poles of 3-pole circuit breaker. Incorporating Thermal-Magnetic trip unit only.
100% rated breakers.
Number of Poles
2, 3 2, 3, 4 2, 3, 4 2, 3, 4
2, 3, 4 2, 3, 4
2, 3, 4
Interrupting Capacity (kA Symmetrical Amperes)
Volts ac (50/60 Hz) Volts dc
240 415 690 250
I
85 85 85 100
100 200 200
I
cu
cs
85 85 85 100
100 100 100

I
cs
10 10 — 10
— 10 —
For more information visit: www.EatonElectrical.com CA08102001E
Circuit Breakers & Supplementary Protectors 125 – 600 Amperes
45-85
August 2006
L-Frame
L-Frame Digitrip Specifications
Table 45-146. Specifications
Trip Unit Type Digitrip RMS 310 Digitrip OPTIM 550 Digitrip OPTIM 1050
rms Sensing Ye s Ye s Ye s
Breaker Type
Frame LLL
Ampere Range 300 – 600 A 200 – 600 A 200 – 600 A
Interrupting Rating at 480 Volts 35, 65, 100 (kA) 35, 65, 100 (kA) 35, 65, 100 (kA)
Protection
Ordering Options LS, LSG LSI, LSIG LSI, LSI(A), LSIG LSI(A), LSIG
Fixed Rated Plug (I
Overtemperature Trip Yes Yes Yes Yes
Long Delay Protection (L)
Adjustable Rating Plug (In)YesYesNoNo
Long Delay Pickup 0.5 – 1.0 (I
Long Delay Time I
Long Delay Time I
Long Delay Thermal Memory Yes Yes Yes Yes
High Load Alarm No No 0.5 – 1.0 x I
Short Delay Protection (S)
Short Delay Pickup 200 – 800% x (In) 200 – 800% x (In) 150 – 800% x (Ir) 150 – 800% x (Ir)
Short Delay Time I
Short Delay Time Flat No Inst – 300 ms 100 – 500 ms 100 – 500 ms
Short Delay Time Zone Selective Interlocking No No Yes
Instantaneous Protection (I)
Instantaneous Pickup No 200 – 800% x (In) 200 – 800% x (In) 200 – 800% x (In)
Discriminator No No Yes Yes
Instantaneous Override Yes Yes Yes Yes
Ground Fault Protection (G)
Ground Fault Alarm No No 20 – 100% x (Is) 20 – 100% x (Is)
Ground Fault Pickup 1 – 5 x I
Ground Fault Delay I
Ground Fault Delay Flat Inst – 500 ms Inst – 500 ms 100 – 500 ms 100 – 500 ms
Ground Fault Zone Selective Interlocking No No Yes
Ground Fault Thermal Memory Yes Yes Yes Yes
System Diagnostics
Status LEDs Yes Yes Yes Yes
Cause of Trip LEDs No No Yes Yes
Magnitude of Trip Information No No Yes Yes
Remote Signal Contact — Ground Alarm Yes
Local Auxiliary and Bell Alarm Contact Optional Optional Optional Included
System Monitoring
Digital Display No No Yes
Current No No Yes Yes
Power and Energy No No No Yes
Power Quality — Harmonics No No No Yes
Power Factor No No No Yes
Communications
Cutler-Hammer PowerNet No No Yes
Testing
Testing Method Test Set OPTIMizer, BIM, Cutler-Hammer PowerNet
Adjust by rating plug.
By OPTIMizer/BIM.
Eaton’s Cutler-Hammer PowerNet kit.
Zone interlock kit.
With separate ground fault alarm unit (GFAU).
) Yes Yes Yes Yes
n
)
2
t 12 Seconds 12 Seconds 2 – 24 Seconds 2 – 24 Seconds
4
t No No 1 – 5 Seconds 1 – 5 Seconds
2
t 100 ms No 100 – 500 ms 100 – 500 ms
2
t No No 100 – 500 ms 100 – 500 ms
n
(120 A) 1 – 5 x Ig (120 A) 20 – 100% x (Is) 20 – 100% x (Is)
g
0.5 – 1.0 (In)
Ye s
0.4 – 1.0 x (In) 0.4 – 1.0 x (In)
0.5 – 1.0 x I
Ye s
Ye s
Ye s
Ye s
Ye s
Ye s
r
Legend: BIM = Breaker Interface Module
(A) = GF Alarm
= Sensor Rating
I
s
= Rating Plug
I
n
= Long Delay Pickup Setting
I
r
r
45
CA08102001E For more information visit: www.EatonElectrical.com
45-86
Circuit Breakers & Supplementary Protectors 125 – 600 Amperes
L-Frame
Dimensions/Weights
Table 45-147. Dimensions in Inches (mm)
Number of Poles Width Height Depth
2, 3 4
Table 45-148. Approximate Shipping Weight, Lbs. (kg)
Breaker Type
LD, HLD, LDC LDB
8.25 (209.6)
11.00 (279.4)
Complete Breaker Frame Only Trip Unit
Number of Poles
234 234234
18 (8.2) 18 (8.2)
20 (9.1) 20 (9.1)
10.75 (273.1)
10.75 (273.1)
25 (11.3) 25 (11.3)
4.06 (103.1)
4.06 (103.1)
14 (6.4) —
15 (6.8) —
20 (9.1) —
3 (1.4) —
4 (1.8) —
August 2006
5 (2.3) —
45
For more information visit: www.EatonElectrical.com CA08102001E
Circuit Breakers & Supplementary Protectors 125 – 600 Amperes
August 2006
L-Frame
Product Selection
This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.
Table 45-149. Circuit Breaker/Frame Catalog Numbering System
LD 3 600 F
45-87
Circuit Breaker/
Frame Type
LDB LD HLD LDC CLD CHLD CLDC
Number of Poles
2 = 2 Poles 3 = 3 Poles 4 = 4 Poles
Circuit Breaker/
Frame Ampere
Rating
300 350 400 450 500 600
Table 45-150. Thermal-Magnetic Trip Unit Catalog Numbering System
LT 3 400 T
Trip Unit Type
LT = Thermal
Magnetic
Table 45-151. OPTIM Circuit Breaker/Frame Catalog Numbering System
Number of Poles
2 = 2 Poles 3 = 3 Poles 4 = 4 Poles
Trip Unit Rating/
Plug Ampere Rating
300 350 400 450 500 600
LD 3 125 T5 7 W
Suffix
C = Copper Terminals F = Frame Only K = High Magnetic Molded Case Switch V = 50°C (Thermal-Magnetic Trip Units Only) W = Without Terminals X = Load Side Terminals Only Y = Line Side Terminals Only
Suffix
T = Trip Unit Thermal-Magnetic
Fixed Thermal Adjustable Magnetic
V = 50°C Calibration
(Thermal-Magnetic Trip Units Only)
45
Circuit Breaker/
Frame Type
LD HLD LDC CLD CHLD CLDC
Number of Poles
3 = 3 Poles
Circuit Breaker/
Frame Ampere Rating
125 = (Available on Model 1050 Only) 250 = (Available on Model 1050 Only) 400 600
Trip Type
2 = LSI (550 Only) 6 = LSIG 7 = LSIA
Trip Model
T5 = Model 550 T10 = Model 1050
Table 45-152. Digitrip RMS 310 Trip Unit Catalog Numbering System
LES 3 600 LS P
Trip Unit Type
LES = Electronic
CA08102001E For more information visit: www.EatonElectrical.com
Number of Poles
3 = 3 Poles 4 = 4 Poles
Trip Unit
Ampere
Rating
600
LS LSI LSG LSIG
Suffix
P = 100% Protected
Suffix
W = Without Terminals
Suffix
Neutral on 4-Pole Trip Unit
45-88
45
Circuit Breakers & Supplementary Protectors 125 – 600 Amperes
L-Frame
Product Selection
Table 45-153. Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
Maximum Continuous Ampere Rating at 40°C
2-Pole
300 350 400 450 500 600
3-Pole
300 350 400 450 500 600
4-Pole
300 350 400 450 500 600
Magnetic trip range 5 – 10 times continuous ampere rating.
Individually packed.
Terminal kits contain one terminal for each pole and one terminal cover.
Neutral is in right pole.
Standard Interrupting Capacity 600 Vac Rated 35 kAIC at 480 Vac
Factory Assembled Circuit Consisting of Frame, Trip Unit and Terminals
Catalog Number
LD2300 LD2350 LD2400 LD2450 LD2500 LD2600
LD3300 LD3350 LD3400 LD3450 LD3500 LD3600
LD4300 LD4350 LD4400 LD4450 LD4500 LD4600
Price U.S. $
High Interrupting Capacity 600 Vac Rated 65 kAIC at 480 Vac
Factory Assembled Circuit Consisting of Frame, Trip Unit and Terminals
Catalog Number
HLD2300 HLD2350 HLD2400 HLD2450 HLD2500 HLD2600
HLD3300 HLD3350 HLD3400 HLD3450 HLD3500 HLD3600
HLD4300 HLD4350 HLD4400 HLD4450 HLD4500 HLD4600
Price U.S. $
Ultra High Interrupting Capacity Current Limiting 600 Vac Rated 100 kAIC at 480 Vac
Factory Assembled Circuit Consisting of Frame, Trip Unit and Terminals
Catalog Number
LDC2300 LDC2350 LDC2400 LDC2450 LDC2500 LDC2600
LDC3300 LDC3350 LDC3400 LDC3450 LDC3500 LDC3600
LDC4300 LDC4350 LDC4400 LDC4450 LDC4500 LDC4600
Price U.S. $
Thermal-Magnetic Trip Unit Only
For Use with Standard or High or Ultra High Interrupting Frames
Catalog Number
LT2300T LT2350T LT2400T LT2450T LT2500T LT2600T
LT3300T LT3350T LT3400T LT3450T LT3500T LT3600T
LT4300T LT4350T LT4400T LT4450T LT4500T LT4600T
Price U.S. $
August 2006
Standard Terminals Only
See Page 45-101 for Optional Terminals
Catalog Number
TA602LD TA602LD TA602LD TA602LD TA602LD 2TA603LDK
TA602LD TA602LD TA602LD TA602LD TA602LD 3TA603LDK
TA602LD TA602LD TA602LD TA602LD TA602LD 4TA603LDK
Price U.S. $
Table 45-154. Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers — Frame Only
Standard Interrupting Capacity 600 Vac Rated 35 kAIC at 480 Vac
Catalog Number
Price U.S. $
2-Pole
LD2600F HLD2600F LDC2600F
3-Pole
LD3600F HLD3600F LDC3600F
4-Pole
LD4600F HLD4600F LDC4600F
High Interrupting Capacity 600 Vac Rated 65 kAIC at 480 Vac
Catalog Number
Price U.S. $
Ultra High Interrupting Capacity Current Limiting 600 Vac Rated 100 kAIC at 480 Vac
Catalog Number
Price U.S. $
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CB-2
For more information visit: www.EatonElectrical.com CA08102001E
Circuit Breakers & Supplementary Protectors 125 – 600 Amperes
August 2006
Types LD, HLD and LDC Electronic Circuit Breakers with Interchangeable Trip Units
Order as individual components: Breaker Frame, Trip Unit, Rating Plug, Terminals.
Table 45-155. Types LD, HLD and LDC Electronic Circuit Breakers with Interchangeable Trip Units
Maxi­mum Contin­uous Ampere Rating at 40°C
3-Pole
600 LD3600F HLD3600F LDC3600F LES3600LS LES3600LSI LES3600LSG LES3600LSIG 300
4-Pole
600 LD4600F HLD4600F LDC4600F LES4600LS LES4600LSI — 300
Circuit Breaker Frame Only Digitrip RMS 310 Trip Unit Only
Standard Inter­rupting Capacity 600 Vac
Rated 35 kAIC at 480 Vac
Catalog Number Catalog Number Catalog Number
See Table 45-156 below for prices. Individually packed. For ac use only. Neutral is in right pole. Terminal kits contain one terminal for each pole and one terminal cover.
High Inter­rupting Capacity 600 Vac Rated 65 kAIC at 480 Vac
Ultra High Inter­rupting Capacity Current Limiting 600 Vac Rated 100 kAIC at 480 Vac
L-Frame
L – Adjustable Long Delay Pickup (By Adjustable
Rating Plug)
S – Adjustable Short Delay Pickup with Fixed Short
Delay Time (I Delay Time (Flat Response)
I – Adjustable Instantaneous Pickup by Setting
Short Delay Time to Instantaneous
G – Adjustable Ground Fault Pickup with Adjustable
Ground Fault Delay (Flat Response)
2
t Response) or Adjustable Short
Digitrip RMS 310 Rating Plug Only Standard
Ampere Rating
350 400 450 500 600
350 400 450 500 600
Fixed Rating Plug
6LES300T 6LES350T 6LES400T 6LES450T 6LES500T 6LES600T
6LES300T 6LES350T 6LES400T 6LES450T 6LES500T 6LES600T
Adjustable Rating Plug
Ampere Rating
300/400/ 500/600
A6LES600T1
300/400/ 500/600
A6LES600T1
420/440/ 460/480
A6LES400T5
520/540/ 560/580
A6LES500T5
Terminals Only
See Page 45-101 for Optional Terminals
TA602LD
TA602LD
TA602LD
TA602LD 3TA603LDK
TA602LD
TA602LD
TA602LD
TA602LD 4TA603LDK
45-89
45
Table 45-156. Types LD, HLD and LDC Electronic Circuit Breakers with Interchangeable Trip Units Prices
Catalog Number
A6LES600T1 HLD3600F HLD4600F LDC3600F LDC4600F —
Price U.S. $
Catalog Number
LD3600F LD4600F LES3600LS LES3600LSG LES3600LSI —
Price U.S. $
Catalog Number
LES3600LSIG LES4600LS LES4600LSI TA602LD 3TA603LDK —
Price U.S. $
Catalog Number
4TA603LDK 6LES300T 6LES350T 6LES400T 6LES450T 6LES500T
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CB-2
Price U.S. $
Catalog Number
6LES600T — — A6LES400T5 A6LES500T5 —
Price U.S. $
CA08102001E For more information visit: www.EatonElectrical.com
Loading...
+ 13 hidden pages