Cutler Hammer, Div of Eaton Corp Circuit Breakers, Supplementary Protectors Accessories Catalog

Circuit Breakers & Supplementary Protectors 10 – 225 Amperes
August 2006
Allowable Accessory Combinations
Table 45-108. Accessories
Description Reference
Internal Accessories (Only one internal accessory per pole)
Alarm Lockout Switch (Make Only) 45-109
Alarm Lockout (Make/Break) 45-109
Alarm Lockout (2Make/2Break) 45-109
Auxiliary Switch (1A, 1B) 45-112
Auxiliary Switch (2A, 2B) 45-112
Auxiliary Switch and Alarm Switch Combination 45-114
Shunt Trip — Standard 45-116
Shunt Trip — Low Energy 45-119
Undervoltage Release Mechanism 45-120
External Accessories
End Cap Kit 45-128
Keeper Nut 45-128
Control Wire Terminal Kit 45-129
Multiwire Connectors 45-130
Base Mounting Hardware 45-131
Terminal Shields 45-132
Terminal End Covers 45-133
Interphase Barriers 45-133
Non-Padlockable Handle Block 45-135
Snap-on Padlockable Handle Lock Hasp 45-135
Padlockable Handle Lock Hasp 45-136
Cylinder Lock 45-136
Key Interlock Kit 45-137
Sliding Bar Interlock — Requires Two Breakers 45-138
Walking Beam Interlock — Requires Two Breakers 45-138
Electrical (Solenoid and Motor) Operators 45-139
Plug-in Adapters 45-141
Rear Connecting Studs 45-142
Panelboard Connecting Straps 45-145
Handle Mechanisms 45-146
LFD Current Limiter 45-151
IQ Energy Sentinel 45-151
Modifications (Refer to Eaton)
Special Calibration
Moisture Fungus Treatment
Freeze-Tested Circuit Breakers
Marine Application
Applicable in indicated pole position May be mounted on left or right pole —
F-Frame
Page
not both
1-Pole 2-Pole 3-Pole 4-Pole
Center Left Right Left Center Right Left Center Right Neutral
■❏ ❏■
■❏ ❏■
■■ ■■
■■ ■■
■❏ ❏■
■■ ■■
■■ ■■
■■ ■■
●●
●●
●●
●●
●●
●●
●●
■■
■■
■❏ ❏❏
■❏ ❏❏
●●
●●
●●
●●
●●
●●
●●
●●
●●
●●
Accessory available/Modification available
45-61
45
CA08102001E For more information visit: www.EatonElectrical.com
August 2006
Circuit Breakers & Supplementary Protectors Internal Accessories
Alarm Switch
45-109
Alarm Switch
Make
Break
voltage release is operated. A “make” contact closes and a “break” contact opens when the alarm/lockout switch operates. The switch automatically resets when the circuit breaker is reset.
For remote indication of automatic trip operation. Does not function with manual switching; how­ever, it will operate when either a shunt trip or under-
Table 45-181.
Maximum Voltage
F-Frame Electrical Rating Data
Frequency Maximum
Current Amperes
Dielectric Withstand Voltage
Multi-Pole Circuit Breakers
600 125 250
50/60 Hz dc dc
6
0.50
0.25
2500
Single-Pole Circuit Breakers
125/250 28 28
Endurance: 6000 electrical operations plus 4000 mechanical operations.
Endurance: 6000 electrical operations plus 2000 mechanical operations.
Non-inductive load.
Inductive (L/R = 0.026).
Table 45-182.
Maximum Voltage
600 125 250
Endurance: 6000 electrical operations plus 2000 mechanical operations.
Pigtail wire size: 18 AWG (0.82 mm2).
Non-inductive load.
50/60 Hz dc dc
J-Frame Electrical Rating Data
Frequency Maximum
50/60 Hz dc dc
6
3
5
Current Amperes
6
0.50
0.25
2000
Dielectric Withstand Voltage
2500


Table 45-183.
Maximum Voltage
600 125 250
Pigtail wire size: 18 AWG (0.82 mm2).
Endurance: 5,000 electrical operations plus 1000 mechanical operations.
Non-inductive load.
Table 45-184. L-Frame Electrical Rating Data
Maximum Voltage
600 125 250
Pigtail wire size: 18 AWG (0.82 mm2).
Endurance: 5,000 electrical operations plus 1000 mechanical operations.
Non-inductive load.
K-Frame Electrical Rating Data
Frequency Maximum
50/60 Hz dc dc

Frequency Maximum
50/60 Hz dc dc
Current Amperes
6
0.50
0.25
Current Amperes
6
0.50
0.25
 
 
Dielectric Withstand Voltage
2500
Dielectric Withstand Voltage
2500

45
CA08102001E For more information visit: www.EatonElectrical.com
45-110
Circuit Breakers & Supplementary Protectors Internal Accessories
August 2006
Alarm Switch
45
Table 45-185. G-Frame Alarm Switch (RH Only)
Electrical Ratings Contact Volts Frequency Amperes
Arrangement
Factory Suffix
Adder U.S. $
Catalog Number

Price U.S. $
Alarm Switch
240 50/60 Hz 6 1 Make/1 Break
B3
1288C75G03
Alarm Switch Auxiliary Switches Combination
240 50/60 Hz 6 1 Make/1 Break and 1a/1b
F-Frame circuit breakers are factory sealed. Underwriters Laboratories, requires that internal accessories be installed at the factory. Internal accesso-
B13
1288C76G09
ries are UL listed for factory installation under E7819. Where local codes and standards permit and UL listing is not required, internal accessories can be field installed. Accessory installation should be done before the circuit breaker is mounted and connected.
Includes 24-inch (609.6 mm) external pigtail leads,18 AWG (16-.010).
A maximum of two internal accessories may be mounted in a 3-pole circuit breaker.
Suitable for mounting in right pole only of 2- or 3-pole breaker.
Table 45-186. F-Frame and HMCP (F) Alarm Switch
Number of Contacts (Make and Break)
1 Left
2 Left
1 (Make Only)
F-Frame circuit breakers are factory sealed. Underwriters Laboratories, requires that internal accessories be installed at the factory. Internal accesso-
Mounting Location (Pole)
Right
Right
Single­Pole
Factory Mounted Field Mounted Connection Type and Location Field Installation Kits 18-Inch (457.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block Same Side Rear Suffix
Number
Adder U.S. $
B01 B05
B09 B12
B15

Suffix Number
B02 B06
B10 B13
Adder U.S. $
Opposite Side Same Side Suffix
Number
B03 B07
— —
Adder U.S. $
Suffix Number
B04 B08
B11 B14
Adder U.S. $
Catalog Number
A1L1LPK A1L1RPK
A2L1LPK A2L1RPK
Price U.S. $
Catalog Number
A1L1LTK A1L1RTK
A2L1LTK A2L1RTK
Price U.S. $
———— —
ries are UL listed for factory installation under E7819. Where local codes and standards permit and UL listing is not required, internal accessories can be field installed. Accessory installation should be done before the circuit breaker is mounted and connected.
Not listed with Underwriters Laboratories, for field installation.
For F-Frame HMCP, add “M” to the beginning of catalog number.
Standard pigtail lead exit location.
Standard mounting location.
Factory installation only. Leads exit load end of circuit breaker.
Table 45-187. J-Frame and HMCP (J) Alarm Switch
Number of Contacts (Make and Break)
1 Left
Listed with Underwriters Laboratories, for field installation on interchangeable trip unit breakers under E64983.
Standard mounting location.
Standard mounting location — leads exit rear of breaker.
Standard pigtail lead exit location.
Mounting Location (Pole)
Right
Factory Mounted Field Mounted Connection Type and Location Field Installation Kits 18-Inch (457.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block Same Side Rear Suffix
Number
Adder U.S. $
B01 B05
Suffix Number
B02 B06
Adder U.S. $
Opposite Side Same Side Suffix
Number
B03 B07
Adder U.S. $
Suffix Number
B04 B08
Adder U.S. $
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CB-2
Catalog Number
A1L2LPK A1L2RPK
Price U.S. $
Catalog Number
A1L2LTK A1L2RTK
Price U.S. $
For more information visit: www.EatonElectrical.com CA08102001E
45-112
45
Circuit Breakers & Supplementary Protectors Internal Accessories
Auxiliary Switch
Auxiliary Switch
The Auxiliary Switch provides circuit breaker con-
a
tact status information by monitoring the position of the molded cross bar which contains the mov-
b
ing contact arms. The auxiliary switch is used for
tion, and consists of one or two SPDT switches housed in a plug-in module. Each SPDT switch has one “a” and one “b” contact. When the circuit breaker contacts are open, the “a” contact is open and the “b” contact is closed.
Table 45-190. F-Frame Electrical Rating Data
Maximum Voltage
125 600 125 250
Endurance: 6000 electrical operations plus 4000 mechanical operations.
Pigtail wire size: 18 AWG (0.82 mm2).
For use in electronic circuit of 100 micro amperes and 15 Vdc minimum.
Non-inductive load.
Table 45-191. J-Frame Electrical Rating Data
Maximum Voltage
600 125 250
Endurance: 6000 electrical operations plus 4000 mechanical operations.
Pigtail wire size: 18 AWG (0.82 mm2).
Non-inductive load.
remote indication and interlock system verifica-

Frequency Maximum
50/60 Hz 50/60 Hz dc dc
Frequency Maximum
50/60 Hz dc dc
Current Amperes
1 6
0.50
0.25
Current Amperes
6
0.50
0.25

Dielectric Withstand Voltage
2500
Dielectric Withstand Voltage
2500
August 2006
Table 45-192. K-Frame Electrical Rating Data
Maximum Voltage
600 125 250
Endurance: 5000 electrical operations plus 1000 mechanical operations.
Pigtail wire size: 18 AWG (0.82 mm2).
Non-inductive load.
Frequency Maximum
Current Amperes
50/60 Hz dc dc
6
0.50
0.25
Table 45-193. L-Frame Electrical Rating Data
Maximum Voltage
600 125 250
Pigtail wire size: 18 AWG (0.82 mm2).
Non-inductive load.
Frequency Maximum
Current Amperes
50/60 Hz dc dc
6
0.50
0.25

Dielectric Withstand Voltage
 
2500
Dielectric Withstand Voltage
 
2500
Table 45-194. G-Frame Auxiliary Switch (RH only)
Electrical Ratings Contact
Volts Frequency Amperes
240 240
Includes 24-inch external pigtail leads, 18 AWG (16-.010).
A maximum of two internal accessories may be mounted in a 3-pole circuit breaker. Suitable for mounting in right pole only of 2- or 3-pole breaker.
50/60 Hz 50/60 Hz
6 6
Arrangement
1a/1b 2a/2b
Factory Suffix
A3 A6
Adder U.S. $
Catalog

Number
1288C74G03 1288C73G03
Price U.S. $
Table 45-195. F-Frame and HMCP (F) Auxiliary Switch
Number of Contacts a and b
1 Left
2 Left
Standard pigtail lead exit location.
Not listed with Underwriters Laboratories, for field installation.
Pigtail wire size: 18 AWG (0.82 mm2).
125 volts (Max.), 50/60 Hz switch for use in electronic circuit of 100 micro amperes and 15 Vdc minimum.
Not for use on 4-pole circuit breakers.
Mounting Location (Pole)
Right or Neutral
Right or Neutral
Factory Mounted Field Mounted Connection Type and Location Field Installation Kits 18-Inch (457.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block Same Side Rear Suffix
Number
A01 A15 A05 A18
A09 A21 A12 A23
Adder U.S. $
Suffix Number
A02
A16 A06
A19
A10
A22 A13
A24
Opposite Side Same Side
Adder
Suffix
U.S. $
Number
A03
A17 A07
A20
— — — —
Adder U.S. $
Suffix Number
A04 — A08 —
A11 — A14 —
Adder U.S. $
Catalog Number
A1X1PK E1X1PK A1X1PK —
A2X1LPK E2X1LPK A2X1RPK E2X1RPK
Price U.S. $
Catalog Number
A1X1LTK — A1X1RTK —
A2X1LTK — A2X1RTK —
Price U.S. $
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2
For more information visit: www.EatonElectrical.com CA08102001E
45-114
Circuit Breakers & Supplementary Protectors Internal Accessories
Auxiliary Switch and Alarm Switch Combination
Auxiliary Switch and Alarm Switch Combination
Each Catalog Number listed in Tables 45-199 – 45-206 includes one Auxiliary Switch and one
a
Alarm Switch. In an auxiliary switch ASL switch combination, the auxiliary switch is always
b
mounted on the side of the plug-in module next to the center pole of the circuit breaker.
Current Amperes
6
0.50
0.25
Current Amperes
6
0.50
0.25

Dielectric Withstand Voltage
2500 2200 2200

Dielectric Withstand Voltage
2500
Table 45-199. F-Frame Electrical Rating Data
Maximum Voltage
600 125 250
Endurance: 6000 electrical operations plus 4000 mechanical operations.
Pigtail wire size: 18 AWG (0.82 mm2).
Non-inductive load.
Frequency Maximum
50/60 Hz dc dc
Table 45-200. J-Frame Electrical Rating Data
Maximum Voltage
600 125 250
Endurance: 6000 electrical operations plus 2000 mechanical operations.
Pigtail wire size: 18 AWG (0.82 mm2).
Non-inductive load.
Frequency Maximum
50/60 Hz dc dc
August 2006
Current Amperes
6
0.50
0.25
Current Amperes
6
0.50
0.25

Dielectric Withstand Voltage
2500

Dielectric Withstand Voltage
2500
Table 45-201. K-Frame Electrical Rating Data
Maximum Voltage
600 125 250
Endurance: 5000 electrical operations plus 1000 mechanical operations.
Pigtail wire size: 18 AWG (0.82 mm2).
Non-inductive load.
Frequency Maximum
50/60 Hz dc dc
Table 45-202. L-Frame Electrical Rating Data
Maximum Voltage
600 125 250
Endurance: 5000 electrical operations plus 1000 mechanical operations.
Pigtail wire size: 18 AWG (0.82 mm2).
Non-inductive load.
Frequency Maximum
50/60 Hz dc dc
45
For more information visit: www.EatonElectrical.com CA08102001E
Circuit Breakers & Supplementary Protectors Internal Accessories
August 2006
Table 45-203. F-Frame and HMCP (F) Auxiliary Switch and Alarm Switch Combination
Mounting Location (Pole)
Left Right
Not listed with Underwriters Laboratories for field installation.
For F-Frame HMCP, add an “M” to beginning of catalog number.
Standard mounting location.
Not for use on 4-pole circuit breakers.
Factory Mounted Field Mounted
Connection Type and Location Field Installation Kits
18-Inch (457 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block
Same Side Rear
Suffix Number
Adder U.S. $
C01 C04
Suffix Number
C02 C05
Table 45-204. J-Frame and HMCP (J) Auxiliary Switch and Alarm Switch Combination
Number of Sets of Contacts (1a and 1b) (1m – 1b)
1 Left
Listed with Underwriters Laboratories for field installation of interchangeable trip unit breakers under E64983.
Standard mounting location — leads exit rear of breaker.
Not for use on 4-pole circuit breakers.
Mounting Location (Pole)
Right
Factory Mounted Field Mounted
Connection Type and Location Field Installation Kits
18-Inch (457 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block
Same Side Rear
Suffix Number
C01 C04
Adder U.S. $
Suffix Number
C02 C05
Auxiliary Switch and Alarm Switch Combination
Same Side
Adder U.S. $
Adder U.S. $
Suffix Number
C03 C06
Adder U.S. $
Catalog Number
AAL1LPK AAL1RPK
Opposite Side Same Side
Suffix Number
— —
Adder U.S. $
Suffix Number
C03 C06
Adder U.S. $
Price U.S. $
Catalog Number
AAL2LPK AAL2RPK

Catalog Number
AAL1LTK AAL1RTK
Price U.S. $
Catalog Number
AAL2LTK AAL2RTK
45-115
Price U.S. $
Price U.S. $
Table 45-205. K-Frame and HMCP (K) Auxiliary Switch and Alarm Switch Combination
Number of Sets of Contacts (1a and 1b) (1m – 1b)
1 Left
Listed with Underwriters Laboratories for field installation of interchangeable trip unit breakers under E64983.
Standard mounting location — leads exit rear of breaker.
Breakers with K-Frame OPTIM 550 can only accept accessories in left pole.
Will not install on OPTIM Trip (RH).
Mounting Location (Pole)
Right
Factory Mounted Field Mounted
Connection Type and Location Field Installation Kits
18-Inch (457 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block
Same Side Rear
Suffix Number
Adder U.S. $
C01 C04
Suffix Number
C02 C05
Adder U.S. $
Opposite Side Same Side
Suffix Number
— —
Adder U.S. $
Suffix Number
C03 C06
Adder U.S. $
Table 45-206. L-Frame and HMCP (L) Auxiliary Switch and Alarm Switch Combination
Number of Sets of Contacts
1A, 1B and 1 Make/1 Break
2A, 2B and 1 Make/1 Break
3A, 3B and 1 Make/1 Break
Listed with Underwriters Laboratories for field installation under E64983.
Standard mounting location — leads exit rear of breaker.
Not for use on 4-pole circuit breaker.
Mounting Location (Pole)
Left
Right
Left
Right
Left
Right
Factory Mounted Field Mounted
Connection Type and Location Field Installation Kits
18-Inch (457.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block
Same Side Rear
Suffix Number
Adder U.S. $
C01 C04
C07 C10
C14 C15
Suffix Number
C02 C05
C08 C11
— —
Adder U.S. $
Opposite Side Same Side
Suffix Number
— —
— —
— —
Adder U.S. $
Suffix Number
C03 C06
C12 C13
— —
Adder U.S. $
Catalog Number
AAL3LPK AAL3RPK
Catalog Number
AA114LPK AA114RPK
AA214LPK AA214RPK
AA314LPK AA314RPK
Price U.S. $
Price U.S. $
Catalog Number
AAL3LTK AAL3RTK
Catalog Number
AA114LTK AA114RTK
AA214LTK AA214RTK
— —
45
Price U.S. $
Price U.S. $
CA08102001E For more information visit: www.EatonElectrical.com
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2
45-116
Circuit Breakers & Supplementary Protectors Internal Accessories
Shunt Trip
Shunt Trip
The Shunt Trip provides remote controlled tripping of the circuit breaker. The shunt trip
ST
consists of an intermittent rated solenoid with a tripping plunger and a cutoff switch assembled
a
to a plug-in module. When required for ground
shunt trips, as noted in the Electrical Rating Table, are suitable for operation at 55 percent of rated voltage.
fault protection applications, certain ac rated
August 2006
Select shunt trip catalog number for the voltage within the indicated voltage range. Shunt trip coils are designed to be applied at specific ac or dc voltages within the voltage range shown. Electrical ratings are also shown on applicable circuit breaker accessory nameplates.
45
Voltage
12 24
48 60
110 120 125
127 220 250
— — — —
Voltage
12 24
48 60
110 120 125 — — —
110 120 125 127
— — — —

Minimum Operating Voltage
9 100
36 100
77 55
— —
— — — —

Minimum Operating Voltage
8.4 50
33.6 1094
77
— —
154 40
— — — —
VA
400
160
66 71
72 110 140
— — — —
VA
247
1698
112 138 150 — — —
58 — —
— — — —
Table 45-207. F-Frame Electrical Rating Data
50/60 Hz dc
Supply Voltage
12 24
48 60
110 120 127 208 220 240
380 415 440
480 525 550 600
Average unlatching time: 6 milliseconds.
Average circuit breaker contact total opening time: 18 milliseconds.
Endurance: 6000 electrical operations plus 4000 mechanical operations.
Minimum Operating Voltage
6.75 75
36 92
156 480
300 610
300 380
VA Supply
300
140
570 640 180 200 240
130 330
450 530 590
Table 45-208. J-Frame Electrical Rating Data
50/60 Hz dc
Supply Voltage
12 24
48 60
110
120
127
208
220
240
380 400 415 440
480 525 550 600
Average unlatching time: 6 milliseconds.
Average circuit breaker contact total opening time: 18 milliseconds.
Endurance: 6000 electrical operations plus 2000 mechanical operations.
Supply voltages suitable for use with Class 1 GFP devices. Marking label included with accessory kits.
Minimum Operating Voltage
9 31
36 686
60.5 66
285 180
360 34
VA Supply
173
1014
84 102 354 396 432
200 240 610
42 50 60
Voltage
12 24
48 60
110 120 125 — — —
220 250 — —
— — — —
Voltage
12 24
48 60
110 120 125 — — —
220 250 — —
— — — —

Minimum Operating Voltage
8.4 35
77
— — —
154 41
— — — —

Minimum Operating Voltage
9 35
34 710
77
— —
154 — — —
— — — —
VA
170
710 1105
110 130 140 — — —
54 — —
— — — —
VA
170
1105
110 130 140 — — —
41 54 — —
— — — —
Table 45-209. K-Frame Electrical Rating Data
50/60 Hz dc
Supply Voltage
12 24
48 60
110
120
127
208
220
240
380 400 415 440
480 525 550 600
Approximate unlatching time: 6 milliseconds.
Approximate total circuit breaker contact opening time: 8 milliseconds.
Endurance: 5,000 electrical operations plus 1,000 mechanical operations.
Supply voltages suitable for use with Class 1 GFP devices. Marking label included with accessory kits.
Minimum Operating Voltage
9 45
60 100
285 95
360 40
VA Supply
200
830 1280
120 140 420 470 550
108 120 136
50 50 70
Table 45-210. L-Frame Electrical Rating Data
50/60 Hz dc
Supply Voltage
12 24
48 60
110
120
127
208
220
240
380 400 415 440
480 525 550 600
Approximate unlatching time: 6 milliseconds.
Approximate total circuit breaker contact opening time: 18 milliseconds.
Endurance: 5,000 electrical operations plus 1,000 mechanical operations.
Supply voltages suitable for use with Class 1 GFP devices. Marking label included with accessory kits.
Minimum Operating Voltage
9 45
34 830
60 100
266 95
336 40
VA Supply
200
1280
120 140 420 470 550
108 120 136
50 50 70
For more information visit: www.EatonElectrical.com CA08102001E
Circuit Breakers & Supplementary Protectors Internal Accessories
August 2006
Table 45-211. G-Frame Shunt Trip (LH 3-Pole only)
Electrical Ratings Suffix
Volts Frequency Amperes
120 240 12 24 24
50/60 Hz 50/60 Hz dc dc 60 Hz
1.1
2.1
2.8
5.7 —
Note: G-Frame circuit breakers are factory sealed. Underwriters Laboratories requires that internal accessories be installed at the factory. Note: Internal accessories are UL listed for factory installation under E7819. Note: Where local codes and standards permit and UL listing is not required, internal accessories can be field installed. Accessory installation
should be done before the circuit breaker is mounted and connected.
Table 45-212. F-Frame and HMCP (F) Shunt Trip
Voltage Rating (ac Frequency = 50/60 Hz)
Left-Pole Mounting ac/dc Ratings
12 – 24 Vac or dc 48 – 127 Vac or 48 – 60 Vdc 208 – 380 Vac or 110 – 127 Vdc 415 – 600 Vac or 220 – 250 Vdc
Right- or Neutral-Pole Mounting ac/dc Ratings
12 – 24 Vac or dc 48 – 127 Vac or 48 – 60 Vdc 208 – 380 Vac or 110 – 127 Vdc 415 – 600 Vac or 220 – 250 Vdc
Not listed with Underwriters Laboratories, for field installation.
Pigtail wire size: 18 AWG (0.82 mm2).
Standard pigtail lead exit location.
120 Vac marked suitable for ground fault protection devices.
Standard mounting location.
Not for use on 4-pole circuit breakers
Factory Mounted Field Mounted
Connection Type and Location Field Installation Kits
18-Inch (457.2 mm) Pigtail Leads
Same Side Rear
Suffix Number
S01 S05
Adder U.S. $
S09 S13
S17
S21 S25 S29
Suffix Number
S02 S06 S10 S14
S18 S22 S26 S30
Shunt Trip
Number
S1 S2 S3 S4 S7
Adder U.S. $
Adder U.S. $
Terminal Block Pigtail Leads Terminal Block
Opposite Side Same Side
Suffix Number
S03 S07 S11 S15
S19 S23 S27 S31
Adder U.S. $
Suffix Number
S04 S08 S12 S16
S20 S24 S28 S32
Adder U.S. $
Catalog Number
1373D62G01 1373D62G02 1373D62G15 1373D62G16 1373D62G20
Catalog Number
SNT1LP03K SNT1LP08K SNT1LP12K SNT1LP18K
SNT1RP03K SNT1RP08K SNT1RP12K SNT1RP18K
Price U.S. $
Catalog Number
SNT1LT03K SNT1LT08K SNT1LT12K SNT1LT18K
SNT1RT03K SNT1RT08K SNT1RT12K SNT1RT18K
Price U.S. $
Price U.S. $
45-117
45
Table 45-213. J-Frame and HMCP (J) Shunt Trip
Voltage Rating (ac Frequency = 50/60 Hz)
Left-Pole Mounting ac/dc Ratings
12 – 24 Vac or dc 48 – 60 Vac or dc 110 – 240 Vac or 110 – 125 Vdc 380 – 440 Vac or 220 – 250 Vdc 480 – 600 Vac
Right- or Neutral-Pole Mounting ac/dc Ratings
12 – 24 Vac or dc 48 – 60 Vac or dc 110 – 240 Vac or 110 – 125 Vdc 380 – 440 Vac or 220 – 250 Vdc 480 – 600 Vac
Listed with Underwriters Laboratories for field installation under E64983.
Standard mounting location — leads exit rear of breaker.
Suitable for use with Class 1 ground fault sensing element.
Not for use on 4-pole circuit breakers.
Factory Mounted Field Mounted
Connection Type and Location Field Installation Kits
18-Inch (457.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block
Same Side Rear
Suffix Number
S41 S49
S09 S13 S17
S45 S53
S29 S33 S37
Adder U.S. $
Suffix Number
S42 S50 S10 S14 S18
S46 S54 S30 S34 S38
Adder U.S. $
Opposite Side Same Side
Suffix Number
S43 S51 S11 S15 S19
S47 S55 S31 S35 S39
Adder U.S. $
Suffix Number
S44 S52 S12 S16 S20
S48 S56 S32 S36 S40
Adder U.S. $
Catalog Number
SNT2P04K SNT2P06K SNT2P11K SNT2P14K SNT2P18K
SNT2P04K SNT2P06K SNT2P11K SNT2P14K SNT2P18K
Price U.S. $
Catalog Number
SNT2T04K SNT2T06K SNT2T11K SNT2T14K SNT2T18K
SNT2T04K SNT2T06K SNT2T11K SNT2T14K SNT2T18K
    
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CB-2
Price U.S. $
CA08102001E For more information visit: www.EatonElectrical.com
Circuit Breakers & Supplementary Protectors Internal Accessories
August 2006
Low Energy Shunt Trip
Low Energy Shunt Trip devices are designed to operate from low energy
UV
output signals from dedi­cated current sensors typi-
fault protection schemes. However, with a proper control voltage source, they may be applied in place of conventional trip devices for special applications. Flux paths surrounding permanent magnets used in the shunt trip assembly hold a charged spring poised in readiness to operate the circuit breaker trip mechanism.
Table 45-216. F-, J-, K- and L-Frames and HMCPs Low Energy Shunt Trip
Mounting Positions (Pole)
F-Frame
Left Right
J-Frame
Left Right
K-Frame
Left Right
L-Frame
Left Right
Cutoff provisions required in control circuit.
Listed with Underwriters Laboratories for field installation under E64983.
Standard mounting location — leads exit rear of breaker.
For F-Frame HMCP, add an “M” to beginning of catalog number.
For use with thermal-magnetic trip units only.
Breakers with K-Frame OPTIM 550 can only accept accessories in left pole.
cally applied in ground

Factory Mounted Field Mounted
Connection Type and Location Field Installation Kits
18-Inch (457.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block
Same Side Rear
Suffix Number
NO1 NO5
NO1 NO5
NO1 NO5
NO1 NO5
Adder U.S. $
Low Energy Shunt Trip
When a 100 microfarad capacitor charged to 28 Vdc is discharged through the shunt trip coil, the result­ant flux opposes the permanent mag­net flux field, which releases the stored energy in the spring to trip the circuit breaker. As the circuit breaker resets, the shunt trip reset arm is actu­ated by the circuit breaker handle, resetting the shunt trip. The plug-in module is mounted in retaining slots in the top of the trip unit. Coil is inter­mittent-rated only. Cutoff provisions required in control circuit.
Suffix Number
NO2 NO6
NO2 NO6
NO2 NO6
NO2 NO6
Adder U.S. $
Opposite Side Same Side
Suffix Number
NO3 NO7
NO3 NO7
NO3 NO7
NO3 NO7
45-119
Ordering Information
Select shunt trip catalog number for the voltage within the indicated voltage range. Shunt trip coils are designed to be applied at specific ac or dc voltages within the voltage range shown. Electrical ratings are also shown on applicable circuit breaker accessory nameplates.
Adder U.S. $
Suffix Number
NO4 NO8
— —
Adder U.S. $
Catalog Number
LST1LPK LST1RPK
LST2LPK LST2RPK
Price U.S. $
Catalog Number
LST1LTK LST1RTK
— —
Price U.S. $
45
— —
— —
LST3LPK LST3RPK
LST4LPK LST4RPK
— —
— —
CA08102001E For more information visit: www.EatonElectrical.com
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CB-2
45-120
Circuit Breakers & Supplementary Protectors Internal Accessories
August 2006
Undervoltage Release Mechanism
45
Undervoltage Release Mechanism
The Undervoltage Release Mechanism monitors a
UV
voltage (typically a line voltage) and trips the cir-
age falls to between 70 and 35 percent of the solenoid coil rating.
The undervoltage release mechanism consists of a continuous rated sole­noid with a plunger and tripping lever mounted in a plug-in module. The tab on the tripping lever resets the under­voltage release mechanism when normal voltage has been restored and the circuit breaker handle is moved to the reset (or OFF) position. With less than pickup voltage applied to the undervoltage release mechanism, the circuit breaker contacts will not touch when a closing operation is attempted.
Note: Undervoltage release mechanism accessories are not designed for, and should not be used as, circuit interlocks.
Ordering Information
Select handle reset undervoltage release mechanism catalog number for the voltage within the indicated voltage range. Undervoltage release mechanism coils are designed to be applied at specific ac or dc voltages within the voltage range shown on applicable circuit breaker accessory nameplates.
cuit breaker when the volt-
Table 45-217. F-Frame Electrical Rating Data
50/60 Hz dc
Supply Voltage
12 4.2 6.3 7.6 1.3
24 8.4 16.8 20.4 1.4 24 8.4 16.8 20.4 1.6
48 60
110 120 127
208 220 240
380 415 440 480
525 550 600
Dropout Voltage
Minimum Maximum Maximum Minimum Maximum Maximum
21.0 33.6 40.8 1.2
44.5 77.0 93.5 1.3
84.0 145.6 176.8 2.2
168.0 266.0 323.0 2.9
210.0 367.0 446.0 4.3
Endurance: 6,000 electrical operations plus 4,000 mechanical operations.
Pickup Voltage
Table 45-218. J-Frame Electrical Rating Data
50/60 Hz dc
Supply Voltage
12 4.2 8.4 10.2 1.9 12 4.2 8.4 10.2 1.6
24 8.4 16.8 20.4 3.9 24 8.4 16.8 20.4 3.1
48 60
110 120 127
208 220 240
380 415 440 480
Dropout Voltage
Minimum Maximum Maximum Minimum Maximum Maximum
21.0 33.6 40.8 2.5
44.5 77.0 93.5 1.8
84.0 145.6 176.8 2.7
168.0 266.0 323.0 3.4
Endurance: 6,000 electrical operations plus 2,000 mechanical operations. For electrical rating data for manual, automatic and electrical reset undervoltage release
mechanisms, refer to Eaton.
Pickup Voltage
VA Supply
Voltage
12 4.2 8.4 10.2 2.8
2.5
48
1.9
60
110
1.5
120
1.7
125
220
2.4
250
2.9
3.5
3.9
4.6
4.8
5.8

VA Supply
Voltage
48
3.8
60
110
2.1
120
2.4
125
220
3.1
250
3.8
4.0
4.6
5.4
Dropout Voltage
21.0 33.6 40.8 1.3
44.5 77.0 93.5 1.5
87.5
— — — —
— — —
Dropout Voltage
21.0 33.6 40.8 2.0
44.5 77.0 93.5 1.6
87.5
— — — —
154.0
— — — —
— — —
154.0
— — — —
Pickup Voltage
187.0
— — — —
— — —
Pickup Voltage
187.0
— — — —
VA
2.0
1.7
1.9
2.6
3.4 —
— — — —
— — —
VA
3.1
1.9
2.2
3.1
4.0 —
— — — —
For more information visit: www.EatonElectrical.com CA08102001E