All-Copper Mini-Power Center
Product Focus
Three Individual
Components Combined Into
a Single Unit to Save Space
and Installation Costs
Introduction
Eaton’s all-copper Mini-Power
Center incorporates all of
the features and benefits
included in the industry-proven
aluminum model, plus the
additional features of a
copper-wound transformer
with a copper loadcenter
chassis that accepts bolt-on
feeder breakers.
Today’s electrical distribution
systems are required to
do more in less space,
while at the same time be
cost-effective. Eaton provides
a solution that meets both of
these requirements with the
Mini-Power Center.
The Mini-Power Center
combines three individual
components into a single
NEMA Type 3R enclosure;
a primary main breaker, an
encapsulated transformer, and
a secondary main breaker type
distribution loadcenter. All
interconnecting wiring is
completed at the factory.
The all-copper Mini-Power
Center features a copperwound transformer along
with a copper loadcenter
chassis that accepts Eaton’s
Type BAB family of bolt-on
feeder breakers.
Applications
Mini-Power Centers are used
wherever there is a 480 or 600
volt distribution system and
there are loads requiring
120/240 V single-phase or
208Y/120 V three-phase.
Typical installations include:
•
Industrial plant
assembly lines.
•
Plant expansions.
•
Test equipment.
•
Temporary power on
construction sites.
•
Waste water
treatment facilities.
•
Warehouses.
•
Car washes.
•
Parking lots.
•
Commercial buildings.
•
Golf course
irrigation systems.
Easy to Install
•
A variety of concentric
knockouts on the sides
and bottom.
•
Wiring compartment
includes ample space for
conduit entry.
•
Maximum wiring gutter
space is provided for ease
of wiring, in compliance
with NEC requirements.
•
Simplified design includes
two keyholes for easy
mounting and leveling.
All-Copper Mini-Power
Center Components
Circuit Breakers
•
Primary and secondary main
breakers are Eaton Type
EHD or FDB.
•
Feeder circuits can easily
be added using Eaton’s
family of Type BAB
breakers (10 kAIC). Feeder
breakers not included.
Safety
•
All live parts are enclosed
for personnel safety and
equipment protection.
•
Padlockable hinged cover
prevents removal of
feeder breakers.
•
Grounding terminal provided
on the enclosure.
•
Designed to accept
padlock kit PLK1 to lock
primary main breaker
ON/OFF.
Loadcenter
•
Space for up to 30
feeder breakers.
•
Premium copper chassis for
Type BAB bolt-on breakers.
•
Ground bar is provided as
standard for grounding of
individual secondary circuits.
•
Neutral bar grounded
to enclosure.
Enclosures
•
Standard NEMA Type 3R
indoor/outdoor heavy
gauge steel enclosure with
a rugged baked-polymer
powder coating.
•
Optional NEMA Type 3R
grade 316 stainless steel.
Transformer
•
Electrical grade
copper windings.
•
185ºC insulation system.
•
115ºC winding
temperature rise.
•
Sand and resin encapsulated
core-coil assembly.
•
Cores are grounded with a
copper lead.
Standards
•
UL listed and
CSA certified.
•
UL listed as suitable for
service entrance.
•
Meets all applicable
ANSI, NEMA, IEEE and
UL standards.
Compare the Installation Cost Savings — 31 Percent Less
Because we knew that putting three components in one enclosure dramatically cuts installation time, we asked an electrical
contractor to estimate the job two ways:
•
Using a separate breaker, transformer and loadcenter, including
the connecting cable and hardware.
•
Using a Mini-Power Center.
HERE ARE THE ESTIMATES:
Installation 15 kVA 25 kVA
Three- Mini- Three- MiniComponent Power Component Power
System Center System Center
Hours 1
Switch and Fuse Layout
Switch and Fuse Mount
Transformer Layout,
Remove Knockout, etc.
Transformer Fastened to Wall
Loadcenter Layout,
Mount and Connect Source
Total Hours
4040
1010
16 16 24 24
4040
446 4
29 20 39 28
Normal Layout
Fused
Switch
15 kVA
3-Phase
Transformer
72" Wide
Compare the Space Savings…30 Inches Instead of 72 Inches! Specify the
Mini-Power Center
Loadcenter
Mini-Power Center
Transformer
Loadcenter
30" Wide
P2
P1
P1 – Primary Breaker
P2 – Secondary Breaker
Take advantage of the Mini-Power Center’s space and cost savings! Have your
architects, design engineers, and buyers insert the Cutler-Hammer Mini-Power Center with
the catalog number in the specification.
% Time Saved with Cutler-Hammer
Mini-Power Center
31% Savings 28% Savings
1 Time estimates are typical and will vary by geographical area.
CATALOG NUMBER INFORMATION
All-Copper Mini-Power Center (Uses Type BAB Feeder Breakers)
Full Feeder
Capacity Breakers 34
Style Taps Dimensions 1 – Inches (mm) Weight Main Circuit Breaker 2 Max. Number Max.
kVA Number FCBN Height Width Depth Lbs. (kg) Frame Primary Secondary 1-Pole 2-Pole 3-Pole Amp
Single-Phase
480 Volts to 120/240 Volts
3P48G11S03CUB 2 @-5% 33.25 (844.6) 12.56 (319.0) 9.66 (245.4) 105 (47) 306 EHD2015 BAB2015 12 6 4 12
5P48G11S05CUB 2 @-5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 EHD2020 BAB2025 18 9 6 20
7.5 P48G11S07CUB 2 @-5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 EHD2030 BAB2030 18 9 6 30
10 P48G11S10CUB 2 @-5% 40.85 (1037.6) 13.47 (342.1) 11.82 (300.2) 180 (82) 308 EHD2040 BAB2050 18 9 6 40
15 P48G11S15CUB 2 @-5% 43.91 (1115.3) 14.97 (380.2) 11.82 (300.2) 215 (98) 309 EHD2060 BAB2070 24 12 8 60
25 P48G11S25CUB 2 @-5% 43.37 (1101.6) 20.41 (518.4) 14.58 (370.3) 385 (175) 310 EHD2100 BAB2125 30 15 10 100
600 Volts to 120/240 Volts
3P60G11S03CUB 2 @-5% 33.25 (844.6) 12.56 (319.0) 9.66 (245.4) 105 (47) 306 FDB2015 BAB2015 12 6 4 12
5P60G11S05CUB 2 @-5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 FDB2020 BAB2025 18 9 6 20
7.5 P60G11S07CUB 2 @-5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 FDB2030 BAB2030 18 9 6 30
10 P60G11S10CUB 2 @-5% 40.85 (1037.6) 13.47 (342.1) 11.82 (300.2) 180 (82) 308 FDB2040 BAB2050 18 9 6 40
15 P60G11S15CUB 2 @-5% 43.91 (1115.3) 14.97 (380.2) 11.82 (300.2) 215 (98) 309 FDB2060 BAB2070 24 12 8 60
25 P60G11S25CUB 2 @-5% 43.37 (1101.6) 20.41 (518.4) 14.58 (370.3) 373 (169) 310 FDB2100 BAB2125 30 15 10 100
Three-Phase
480 Volts to 208Y/120 Volts
15 P48G28T15CUB 2 @-5% 36.12 (917.4) 28.75 (730.3) 9.38 (238.3) 320 (145) 289A EHD3040 BAB3050H 18 9 6 40
22.5 P48G28T21CUB 2 @-5% 40.88 (1038.4) 29.88 (759.0) 13.63 (346.2) 565 (257) 290A EHD3070 BAB3070H 18 9 6 60
30 P48G28T30CUB 2 @-5% 41.88 (1063.8) 29.88 (759.0) 13.63 (346.2) 635 (288) 291A EHD3090 BAB3100H 24 12 8 80
600 Volts to 208Y/120 Volts
15 P60G28T15CUB 2 @-5% 36.12 (917.4) 28.75 (730.3) 9.38 (238.3) 320 (145) 289A FDB3030 BAB3050H 18 9 6 40
22.5 P60G28T21CUB 2 @-5% 40.88 (1038.4) 29.88 (759.0) 13.63 (346.2) 565 (257) 290A FDB3050 BAB3070H 18 9 6 60
30 P60G28T30CUB 2 @-5% 41.88 (1063.8) 29.88 (759.0) 13.63 (346.2) 635 (288) 291A FDB3070 BAB3100H 24 12 8 80
1 Not for construction purposes.
2 Main breakers fixed only. No substitutes.
3 Combinations can be selected.
4 Feeder breakers not included. Use Cutler-Hammer Type BAB.
Cutler-Hammer is a federally registered trademark of Eaton Corporation. NEMA is the registered
trademark and service mark of the National Electrical Manufacturers Association. National Electrical
Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, Mass. UL is
a federally registered trademark of Underwriters Laboratories Inc. CSA is a registered trademark of the
Canadian Standards Association.