Table 34-387. Accessories
IEC Contactors & Starters
Freedom MMPs & Manual and Combination Motor Controllers
Types A307, A308, A309 Manual Motor Protectors
Description Catalog
Front Mount Auxiliary Contact Blocks (Carton Quantity = 10 pcs.)
(For use with A307, A308 or A309 MMP. One block per MMP.)
1 SPDT Contact, NO/NC 1NO and 1NC 1 SPDT Contact, NO/NC (Electronic Contact). For use in dusty applications and electronic circuits with rated operational current Ie/AC-15 and DC-13 from 1 to 300 mA at 3 to 60V.
Side Mount Auxiliary Contact Blocks (Carton Quantity = 2 pcs.)
(One block per MMP. Mounts to left side of A307, A308 or A309.)
1NO and 1NC 2NO 2NC
Trip Indicating Contacts — Side Mount
(One block per MMP. Mounts to left side of A307, A308 or A309. Can also be used with side mount auxiliary contact.)
1NO and 1NC for Any Trip (overload or short-circuit), plus 1NO and 1NC for Short-Circuit Trip Only
Number
C320FDC11 C320FMC11 C320FEC11
C320SA11 C320SA20 C320SA02
C320TR11
34-297
Price U.S. $
34
Overload Dial Tamperproof Covers (Carton Quantity = 10 pcs.)
(For sealing the FLA adjustment dial or A307, A308 or A309 MMPs.) (10 covers per bag. Price is for one bag.)
Undervoltage Release
(One release module per MMP. Mounts to right side of A307, A308 or A309. Can not be used with shunt trip.)
120V 60 Hz; 110V 50 Hz 240V 60 Hz; 220V 50 Hz 400V 50 Hz 480V 60 Hz
Undervoltage Release with Early Make Contacts
(One release module per MMP. Mounts to right side of A307, A308 or A309. Can not be used with shunt trip.)
230V 50 Hz 400V 50 Hz 480V 60 Hz
Shunt Trip
(One trip module per MMP. Mounts to right side of A307, A308 or A309. Can not be used with undervoltage release.)
AC 50/60 Hz (100% ON)
20 – 24V
90 – 110V 210 – 240V 350 – 415V 500V
Thru-the-Door Operator
(Type 12, Rated IP65; Rotary Operator Mechanism, lockable with up to 3 padlocks in the OFF position. Includes extension shaft, connecting element and supporting bracket [330 mm depth only] to MMP.)
Black Handle — 150 mm Depth
— 330 mm Depth (Includes supporting bracket)
Red Handle and Yellow Background
— 150 mm Depth — 330 mm Depth (Includes supporting bracket)
Terminal Cover for Box Terminals, 50A A308 MMP Terminal Cover for Box Terminals, 100A A309 MMP Terminal Cover for Cable Lug and Busbar Connection, 100A A309 MMP
AC 50/60 Hz; DC (5 Seconds ON)
20 – 70V
70 – 190V 190 – 330V 330 – 500V —
C320CD1
C320UR120 C320UR240 C320UR400 C320UR480
C320URE240 C320URE400 C320URE480
C320SH24 C320SH120 C320SH240 C320SH480 C320SH500
C320HNB1 C320HNB10
C320HNR1 C320HNR10
C320CT50 C320CT100 C320CT110
Consult sales office for MMP and auxiliary contact Series compatibility information.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1
34
IEC Contactors & Starters
Freedom MMPs & Manual and Combination Motor Controllers
Types A307, A308, A309 Manual Motor Protectors
Table 34-387. Accessories (Continued)
Description Catalog
Three-Phase, Line Side Feeder Connecting Links
For 2 A307 MMPs, 45 mm Spacing, 63A Maximum For 3 A307 MMPs, 45 mm Spacing, 63A Maximum For 4 A307 MMPs, 45 mm Spacing, 63A Maximum For 5 A307 MMPs, 45 mm Spacing, 63A Maximum For 2 A307 MMPs, with Side Mount Accessories, 55 mm Spacing, 63A Maximum For 4 A307 MMPs, with Side Mount Accessories, 55 mm Spacing, 63A Maximum For 2 A307 MMPs, with Side Mount Accessories, 63 mm Spacing, 63A Maximum For 4 A307 MMPs, with Side Mount Accessories, 63 mm Spacing, 63A Maximum
Three-Phase, Line Side Feeder Lug
(For use with A307 MMP and Line Side Feeder Connecting Links)
Number
C320BUS22 C320BUS23 C320BUS24 C320BUS25 C320BUS26 C320BUS27 C320BUS28 C320BUS29
C320BUS20
March 2009
Price U.S. $
Three-Phase, Line Side Feeder Lugs
(For connection to bottom of Line Side Feeder Connecting Link instead of MMP)
Cover
(For Unused Line Side Feeder Connecting Links)
Three-Phase, Line Side Feeder Connecting Links
For 2 A308 MMPs, 55 mm Spacing, 100A Maximum For 3 A308 MMPs, 55 mm Spacing, 100A Maximum For 4 A308 MMPs, 55 mm Spacing, 100A Maximum For 2 A308 MMPs, with Side Mount Accessories, 75 mm Spacing, 100A Maximum For 3 A308 MMPs, with Side Mount Accessories, 75 mm Spacing, 100A Maximum For 4 A308 MMPs, with Side Mount Accessories, 75 mm Spacing, 100A Maximum
Three-Phase, Line Side Feeder Lug
(For use with A308 MMP and Line Side Feeder Connecting Links)
Cover
(For Unused Line Side Feeder Connecting Links)
IP55 Nonmetallic Enclosure (Narrow)
(For use with A307 MMP and Accessories with a maximum width of 54 mm)
Black Handle Red/Yellow Handle
Note: Enclosures will not accept A307 MMP with Side Mounted Trip Indicating Contact
Module (C320TR11)
IP55 Nonmetallic Enclosure (Wide)
(For use with A307 MMP and Accessories with a maximum width of 72 mm)
Black Handle Red/Yellow Handle
Note: Enclosures will not accept A307 MMP with Side Mounted Trip Indicating Contact
Module (C320TR11)
IP55 Nonmetallic Enclosure (Wide)
(For use with A308 MMP and Accessories with a maximum width of 82 mm)
Black Handle Red/Yellow Handle
Note: Enclosures will not accept A308 MMP with Side Mounted Trip Indicating Contact
Module (C320TR11)
IP55 Nonmetallic Flush Mount Plate
(For use with A307 MMP and Accessories with a maximum width of 72 mm)
Black Handle Red/Yellow Handle
Note: Flush Plates will not accept A307 MMP with Side Mounted Trip Indicating Contact
Module (C320TR11)
IP55 Front Plate
(For A307, A308 or A309)
Black Handle Red/Yellow Handle
C320BUS21
C320BUS19
C320BUS32 C320BUS33 C320BUS34 C320BUS35 C320BUS36 C320BUS37
C320BUS31
C320BUS30
C799EMB55 C799EMR55
C799WEB55 C799WER55
C799WGB55 C799WGR55
C799WFB55 C799WFR55
C799FNB55 C799FNR55