34
IEC Contactors & Starters
Freedom MMPs & Manual and Combination Motor Controllers
Type A302 Manual Motor Protectors
Accessories
Table 34-383. Accessories — A302
Description Catalog
Enclosure, Nonmetallic
IP41 General Purpose
IP55 Dust and Water Protection
Conversion Kit (Converts IP41
Enclosure to IP55)
Number
C799MP41
C799MP55
C320MSG1
Price
U.S. $
Conduit Adapter — To convert
PG16 Metric Threads on
C799MP41 and C799MP55 to
1/2" N.P.T. Threads
Enclosure, Semimetallic
UL Listed for NEMA 1, 4, 4X,
12 and 13 Applications
Flush Plate (Cavity Mount),
Nonmetallic
IP41 General Purpose
IP55 Dust and Water Protection
Conversion Kit (Converts IP41
Flush Plate to IP55)
Emergency Pushbutton — For
Enclosures and Flush Plates
E Button
E Button Latch — Pull to Release
Padlock Attachment — For
Enclosures and Flush Plates
C320MSA1
C799MP11
C799FP41
C799FP55
C320MSG2
C320MSE1
C320MSE2
C320MSD
Enclosure with Emergency
Pushbutton and Indicating Light
Enclosure with Padlock
Attachment and Indicating Light
Red Indicating Light
110/120V
220/240V
380/415V
420/500V
500/600V
Green Indicating Light
110/120V
220/240V
380/415V
420/500V
500/600V
Auxiliary Contacts, Side Mounted
1NO-1NC
2NO
1NO-1NC Early Closing
2NO Early Closing
SPDT Logic Level (100 mA,
30V maximum)
C320MSL1A
C320MSL1B
C320MSL1L
C320MSL1C
C320MSL1D
C320MSL2A
C320MSL2B
C320MSL2L
C320MSL2C
C320MSL2D
C320MSC3
C320MSC4
C320MSC6
C320MSC7
C320MSC3L
A302 MMP with
Side Auxiliary Contact
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1
March 2009
Table 34-383. Accessories — A302 (Continued)
Description Catalog
Auxiliary Contacts, Internally Mounted
within MMP Housing
1NO-1NC
Ie (AC-15) = 2A, 230V; 1A, 400V;
(DC-15) = .7A, 60V; .55A, 110V;
I
e
Trip Alarm, Internally Mounted within
MMP Housing. These contacts change
state only when overload trips or short
circuit occurs.
1NO
1NC
Ie (AC-15) = 2A, 230V; 1A, 400V;
(DC-15) = .7A, 60V; .55A, 110V;
I
e
Shunt Trip, Internally Mounted within
MMP Housing
110/120V
220/240V
380/440V
415/480V
550/600V
Undervoltage Release, Internally
Mounted within MMP Housing
110/120V
220/240V
380/440V
415/480V
550/600V
3-Phase Connecting Busbar —
Permits quick line side connection of
adjacent MMPs (600V, 65A Max.)
For Linking 2 MMPs
For Linking 4 MMPs
For Linking 5 MMPs
Terminal Block — Used in conjunction
with 3-Phase Connecting Busbar listed
above (600V, 65A Max.)
Wire Range: 10 – 6 AWG
Busbar Cover — Used to cover unused
Busbar Terminals (box of 10 covers)
IEC Contactors & Starters
Freedom MMPs & Manual and Combination Motor Controllers
Type A302 Manual Motor Protectors
Price
U.S. $
A302 MMP with Undervoltage
Release Module Mounted in Base
3-Phase Connecting Busbar
with Terminal Block, Busbar
Cover and A302 MMPs
Combination Adapter Plate with
A302 MMP and CE15 Contactor
.5A, 500V
.25A, 220V
.5A, 500V
.25A, 220V
Number
C320MSC8
C320MSC1
C320MSC2
C320MST1A
C320MST1B
C320MST1L
C320MST1C
C320MST1D
C320MSR1A
C320MSR1B
C320MSR1L
C320MSR1C
C320MSR1D
C320MSB1
C320MSB2
C320MSB3
C320MSB4
C320MSB10
34-293
34
Combination Adapter Plate —
Permits A302 MMP and
magnetic contactor (Cat. No. CE15)
to be mounted one above the other.
Adapter plate snap mounts to DIN rail.
35 mm DIN Rail — 1 Meter Length MC382MA1
Only one internally mounted accessory can be mounted within MMP housing.
C321MSP
A302 MMP Mounted on DIN Rail
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD-1