February 2007
Lighting Contactors
Open Control
A202 Magnetically Latched
37-17
60A Size
Product Description
The Cutler-Hammer® A202 Lighting
Contactor from Eaton’s electrical business provides a safe and convenient
means for local or remote switching of
relatively large tungsten, fluorescent
or mercury arc lamp loads.
Application Description
■ The Magnetically Latched Lighting
Contactors are designed to withstand
the large initial inrush currents of
tungsten lamp loads without contact
welding.
■ The A202 Contactors are fully rated
devices that do not require de-rating
similar to standard motor control
contactors.
■ The Magnetically Latched Lighting
Contactor provides effective control
in applications such as office buildings, industrial plants, hospitals,
stadiums, airports, etc.
Features
■ Designed and tested specifically for
lighting and resistive loads
■ Easy to install and maintain
■ No control power necessary to
maintain contact closure
Operation
A permanent magnet is built into the
contactor structure that will maintain
the contactor in its energized state
indefinitely without using control
power. When energized, a DC current is
applied to the latch coil, producing a
magnetic field that reinforces the polarity of the permanent magnet, pulling in
the contactor. The coil clearing interlock
disconnects the current to the coil. In
order to drop out the contactor, it is
necessary to apply a field through the
STOP coil in the reverse direction to the
permanent magnet. This momentarily
cancels the magnetic attraction and the
contactor drops out.
Instructional Leaflets
IL16965 30A (2, 3, 4, 5 Poles)
IL16966 60 – 200A (2, 3, 4, 5 Poles)
Standards and Certifications
■ UL Listed File # E44424, Guide NRNT
■ CSA Certified File # LR39402,
Class 3231-01
37
Technical Data and
Specifications
■ Terminals
❑ All except 30A devices: Cu/Al
❑ 30A devices: Cu only
■ Ballast load: 600 AC, breaking all
lines
■ Tungsten lamp loads, maximum
volts
❑ Line-to-line: 480V AC
❑ Line-to-neutral: 277V AC
Accessories
See A200 NEMA Contactor Accessories,
Page 33-194 – 33-196.
Wiring Diagrams
The standard wiring of an A202 contactor can be controlled by a separate
customer supplied
throw controlling station.
Figure 37-8. Standard Wiring
Two-wire control can be accomplished with a customer supplied
relay with 1NO/1NC auxiliary
contacts, wire as shown.
Figure 37-9. Two-Wire Control
single-pole double-
Control Line
L2
(+)
Red3
White
Red3
White
OFF
(+)
(+)
AC
AC
OFF
Red
AC
(–)
Red
(+)
(+)
Red
AC
(–)
Red
ON
Black
Typical
Control
Station
Open
Switch
CM
Control
CM
Close
Line
Line
or
Neutral
Close
Open
2
Standard Wiring
L2
(+)
ON
CM
CM
Black
2
Two-Wire Control
Line
Load
Line
Load
Auxiliary
Contact
(Option)
Auxiliary
Contact
(Option)
CA08102001E For more information visit: www.eaton.com
February 2007
Lighting Contactors
Open Control
A202 Magnetically Latched
37-19
Dimensions
Table 37-39. Approximate Dimensions for Non-combination Open
Lighting Contactors — 2- to 12-Pole
Continuous
Amperes
30 2 – 4
60 2, 3
100 2, 3
200 2, 3
Figure 37-10. Approximate Dimensions
Number of
Poles
5
6
8
10
12
4, 5
6
8
10
12
4, 5
6
8
10
12
4, 5
6
8
10
12
A
Pole
Configuration
3 x 3
4 x 4
5 x 5
4 x 4 x 4
3 x 3
4 x 4
5 x 5
5 x 5 x 2
3 x 3
5 x 3
5 x 5
5 x 5 x 2
3 x 3
5 x 3
5 x 5
5 x 5 x 2
Open Type
Dimensions in Inches (mm)
Open Type
Wide A High B
3.31 (84.1)
4.19 (106.4)
7.13 (181.1)
7.13 (181.1)
10.63 (270.0)
12.38 (314.5)
3.31 (84.1)
4.19 (106.4)
7.13 (181.1)
10.63 (270.0)
10.63 (270.0)
15.00 (381.0)
4.63 (117.6)
7.25 (184.2)
9.75 (247.7)
12.38 (314.5)
15.00 (381.0)
34.13 (866.9)
4.63 (117.6)
7.25 (184.2)
9.75 (247.7)
12.38 (314.5)
15.00 (381.0)
34.13 (866.9)
4.38 (111.3)
4.38 (111.3)
4.46 (113.3)
4.46 (113.3)
4.46 (113.3)
6.88 (174.8)
4.38 (111.3)
4.38 (111.3)
4.46 (113.3)
4.46 (113.3)
4.46 (113.3)
6.88 (174.8)
6.63 (168.4)
6.63 (168.4)
6.88 (174.8)
6.88 (174.8)
6.88 (174.8)
27.50 (698.5)
6.63 (168.4)
6.63 (168.4)
6.88 (174.8)
6.88 (174.8)
6.88 (174.8)
27.50 (698.5)
B
Product Selection
When Ordering Specify
■ Catalog Number with Coil Suffix Code from the Magnet
Coil Selection Table.
■ Any required Accessories.
Table 37-40. Latched AC Lighting Contactors
Holding Circuit Auxiliary Contact or Pushbutton Station Not Included
Continuous
Amperes
(Enclosed)
30 2
60 2
100 2
200 2
300 2
400 2
Lighting contactors are not available with DC coils.
Contactors rated 300A and 400A are mechanically latched.
Underscore (_) indicates missing Code letter for Magnet Coil Selection
— see Magnet Coil Selection Table.
Number of
Poles
3
4
5
6
8
10
12
3
4
5
6
8
10
12
3
4
5
6
8
10
12
3
4
5
6
8
10
12
3
3
Open Type
Catalog
Number
A202K1B_M
A202K1C_M
A202K1D_M
A202K1E_M
A202K1F_M
A202K1G_M
A202K1H_M
A202K1K_M
A202K2B_M
A202K2C_M
A202K2D_M
A202K2E_M
A202K2F_M
A202K2G_M
A202K2H_M
A202K2K_M
A202K3B_M
A202K3C_M
A202K3D_M
A202K3E_M
A202K3F_M
A202K3G_M
A202K3H_M
A202K3K_M
A202K4B_M
A202K4C_M
A202K4D_M
A202K4E_M
A202K4F_M
A202K4G_M
A202K4H_M
A202K4K_M
A202K5B_M
A202K5C_M
A202K6B_M
A202K6C_M
Table 37-41. Magnet Coil Selection
Coil Voltage Catalog Number Suffix
120V, 60 Hz
208V, 60 Hz
277V, 60 Hz
440V/50, 480V/60
600V, 60 Hz
120V/60, 110V/50
220V/50, 240V/60
24V, 60 Hz
Available on 2- to 5-pole, 30 and 60A devices and on 2- to 3-pole 100
and 200A devices.
A
B
Z
X
E
A
W
I
Price
U.S. $
37
CA08102001E For more information visit: www.eaton.com
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . 1CD-1C