Custom Dynamics TF25, TF10, TF15, TF20, TF30 Installation Instructions Manual

...
Custom Dynamics® TruFLEX®
Installation Instructions
We thank you for purchasing the Custom Dynamics® TruFLEX® LED Signals. Our products utilize the latest technology and high quality components to ensure you the most reliable service. We offer one of the best warranty programs in the industry and we back our products with excellent customer support, if you have questions before or during installation of this product please call Custom Dynamics® at 1(800) 382-1388.
Questions? Call us at: 1 (800) 382-1388 M-TH 8:30AM-5:30PM / FR 9:30AM-5:30PM EST
06-2016SM
Product Listing for TruFLEX® Instructions
Single Color Amber or Red LED TruFLEX® LEDs in clear, amber, red or smoked tubing (page 3):
Universal Integrated Run/Brake/Turn TruFLEX® 2 section or 3 section with dual color amber and/or red LEDs:
Dual Color Amber/Red LEDs, in smoked tube (page 5):
2 Section Integrated Dual Color TruFLEX® (page 5):
Standard TruFLEX Driving Lights, White LEDs .5 spacing (page 3):
TF5 TF10 TF15 TF20 TF25
TF30 TF40 TF45 TF50 TF55
TF60 TF65 TF75 TF95 TF100
TF115
Amber/Red (pg.4) TF40ARC TF40ARS TF115ARC TF115ARS
Red/Red/Red (pg.4) TF115RC TF115RR TF115RS
TFDC5S TFDC10S TFDC15S TFDC20S TFDC25S
TFDC30S TFDC35S TFDC40S TFDC75S
TFDC50S TFDC70S TFDC110S
(requires 2 units for left and right turns)
TF6WC TF12WC
TF18WC TF24WC
TruFLEX® Dual Converter Index
Convert TruFLEX® from Single Wire to Dual Wire. Used for Tail Light and Turn Signal Applications. Example: will convert single hot wire to: Running (30% Intensity) and Brake (100% Intensity). Select the Converter Based on the Number of TruFLEX® LEDs you are Converting from Single Wire to Two Wire.
Single Color LED Application TFC1 (5-10 LEDs ) TFC2 (15-25 LEDs) TFC3 (30-60 LEDs) TFC4 (65-120 LEDs) TFC5 (125-160 LEDs)
Dual Color Amber/Red Application TFDC1 (5-25 LEDs ) TFDC2 (30-45 LEDs) TFDC3 (50-110 LEDs)
TFDC90S
TruFLEX® Technical Information:
Board: FR4 LED mounting board
LED's: 120 Degree Viewing Angle, Genesis® Surface Mount type available in amber, red, or white
Voltage: Wide Operating Range: 9-14 VDC
Current Draw: Approximately 25mA for every 5 LEDs
Wire: 36" (3 ft.) Stranded conductor wire 26 AW G gauge
Housing:
- Flexible UV stable channel engineered for maximum flexibility
- Dimensions: 0.34" Wide X 0.30" High X Length
- Color: Choice of Clear, Amber, Red, or Smoked
- Light Dispersion: Facet design increases LED viewing angle
- End Cap: 100% Sealed with UV Stable Military Grade RTV (MIL-A-46146)
Mounting: Pre-Taped with 3MAutomotive Acrylic Plus Attach­ment Tape
The TruFLEX® product is designed to be used as auxiliary lighting on any 12VDC system including motorcycles, auto­mobiles, trucks, boats, ATVs, and snow mobiles for the following applications:
- Running lights
- Turn signals
- Brake lights
Note: the lower number of the converter = lower running power = more contrast
DOT specifies signal color by location:
Amber = Front or Rear turn
Amber = Front running
Red = Rear run/brake/turn
Red/Red (pg.6) TF110RR
Installation Instructions - Page 2
Questions? Call us at: 1 (800) 382-1388 M-TH 8:30AM-5:30PM / FR 9:30AM-5:30PM EST
06-2016SM
General Product Mounting Instructions
ATTENTION
Please read all Information below before Installation
Important: This product is designed and intended for use as auxiliary lighting only. It is NOT intended to replace any original equipment lighting installed on the vehicle and should not be used for that pur­pose. This product must be wired so that it does not interfere with any original equipment lighting.
Note: Please read all instructions before beginning installation. Some wiring knowledge and soldering experience will be helpful. Consult your vehicle detailed service manual for wiring information and color codes. Use a meter or test light to verify wiring before cutting or tapping any vehicle wiring. If the steps contained within are beyond your skillset, do not attempt installation, contact a qualified mechanic or dealership to assist you.
Safety First: Always wear appropriate safety gear including safety glasses when performing any elec­trical work. It is highly recommended that safety glasses be worn throughout this installation process. Turn fuel supply valve to the off position before starting installation. Be sure vehicle is on level sur­face, secure and cool.
Warning: Disconnect negative battery cable from battery; refer to owners manual. Failure do to so may result in electrical shock, injury, or fire. Secure negative battery cable away from positive side of battery and all other positive voltage sources on vehicle.
Note: TruFLEX® products are very flexible but will NOT accommodate hard 90 degree angles. Doing so can cause stress to the board and the LEDs. The product also does not flex from side-to-side, it must be installed in a straight line. Damage or failure from these types of incorrect installation is not covered under warranty.
Recommendation: To increase the adhesion pow­er of the 3M mounting tape, it is recommended to use 3M Adhesion promotor, sold separately.
Note: 3M Adhesion promotor is classified as a sensitive chemical and cannot ship any carrier by Air or international. Custom Dynamics may not be able to ship promotor with orders in these cases. Contact us for details.
Important: It is recommended that the installation of this product should be performed in a controlled environment of 65 F or above. Allow 24 hours for the tape to properly adhere before riding or washing the bike.
1. Choose the desired location to mount the LED strip(s).
2. Clean the surface thoroughly before mounting with appro- priate cleaning method and rubbing alcohol.
3. Note: It is recommended to apply 3M adhesion promotor to the mounting surface to increase tape adhesion, sold sepa­rately. If 3M Promotor ampule was purchased, open the vile and apply generously to the mounting surface. Allow 3-4 minutes to dry.
4. Inspect the vehicle and plan the route the wiring will make to the connection point. Keep in mind each unit has 36” of wiring. Consult vehicle detailed service manual for vehicle wiring information and wire color codes. Use a meter or test light to verify vehicle wire functions before connecting.
5. Drill holes if necessary in the mounting surface to allow for the wiring to pass. Feed the wiring through the holes.
6. Remove the Red backing from the Tape and carefully mount in the desired location, paying attention to the de­sired level and center. Take care in this step as once the tape adheres to the surface, it will be very hard to remove and re-apply and is not recommended.
7. Dress the wiring with shrink tubing (not included) as needed to protect wiring from sharp metal or openings, then run the wiring along the chosen route from step 4. Make sure wiring cannot be accidently cut, pinched, or frayed by moving or sharp parts. Keep wiring from coming in direct contact with high heat components.
8. Once you have reached the chosen connection point, trim any excess wiring from LED wires the and prepare the wir­ing ends by stripping back the insulation.
Wiring the Connections
1. All single color TruFLEX® are a 2 wire power system. Black is always Ground, which should be connected to a suitable ground wire in the vehicles wiring harness or di­rectly to the Negative [ - ] terminal of the battery. The Col­ored wire is always the Power [ + ] which should be con­nected to the vehicle turn, brake, or running light positive power wire depending on desired application.
2. All dual color and 2 or 3 section TruFLEX® will have more wires depending on configuration, but the same color rules apply. Black is ground and colored wires are positive.
3. Depending on the type of TruFLEX® you have purchased (see page 1 for product listing) and which converters pur­chased, please refer to the corresponding pages for wiring diagrams and scenarios.
Installation Instructions - Page 3
Questions? Call us at: 1 (800) 382-1388 M-TH 8:30AM-5:30PM / FR 9:30AM-5:30PM EST
06-2016SM
Part Numbers:
TF5 TF10 TF15 TF20 TF25
TF30 TF40 TF45 TF50 TF55
TF60 TF65 TF75 TF95 TF100
TF115
Single Color Amber or Red LED TruFLEX® LEDs in clear, amber, red or smoked tubing
Use weatherproof splice connectors or Posi-taps for connections or solder wire connections.
Make sure to insulate solder connections with heat shrink tubing or electrical tape.
If using as Turns, 2 TruFLEX® LED strips are re­quired for Left and Right Turn.
TruFLEX® Amber or Red: One Function
Colored wire = Positive [ + ]
Black wire = Negative [ - ]
Vehicle Ground [ - ]
Vehicle Run, turn or brake [ + ]
Colored wire = Positive [ + ]
Black wire = Negative [ - ]
TruFLEX® Amber or Red: Hi/Low Function
TFC Dual Converter
Red = High
Orange = Low
Vehicle Ground [ - ]
Vehicle Running light
Vehicle Brake or Turn
= Connection Points
TruFLEX® White Driving Lights : One Function
Colored wire = Positive [ + ]
Black wire = Negative [ - ]
Vehicle Ground [ - ]
Vehicle Constant Power [ + ]
= Connection Points
TF6WC TF12WC
TF18WC TF24WC
Standard TruFLEX Driving Lights, White LEDs (.5 spacing)
Part Numbers:
Use weatherproof splice connectors or Posi-taps for connections or solder wire connections.
Make sure to insulate solder connections with heat shrink tubing or electrical tape.
Installation Instructions - Page 4
Questions? Call us at: 1 (800) 382-1388 M-TH 8:30AM-5:30PM / FR 9:30AM-5:30PM EST
06-2016SM
Universal Integrated Run/Turn or Run/Brake/Turn TruFLEX® 3 section Amber/Red/Amber
Left Turn = Amber
Black = LED Ground
Yellow = Left Turn
Vehicle Ground
Vehicle Left Turn
Right Turn = Amber Center Brake = Red
Part Numbers:
3 Section Amber/Red/Amber: TF40ARC TF40ARS TF115ARC
Use weatherproof splice connectors or Posi-taps for connections or solder wire connections.
Make sure to insulate solder connections with heat shrink tubing or electrical tape.
*Diagram Shows wiring as Run/Brake/Turn with TFC Dual Converter.
Vehicle Right Turn
TFC Dual
Converter
= Connection Points
Red = Center Brake
Red = Brake
Orange = Running
Vehicle Brake
Vehicle Running
*For Single function on Brake, Omit the Dual Converter. Cap any unused wires to prevent shorting.
3 Section Red/Red/Red: TF115RC TF115RR TF115RS
Left Turn = Red
Black = LED Ground
Red = Left Turn
Vehicle Ground
Vehicle Left Turn
Right Turn = Red Center Brake = Red
Part Numbers:
Use weatherproof splice connectors or Posi-taps for connections or solder wire connections.
Make sure to insulate solder connections with heat shrink tubing or electrical tape.
*Diagram Shows wiring as Run/Brake/Turn with TFC Dual Converter.
*Some models may have individual ground wires for each board section.
Vehicle Right Turn
TFC Dual
Converter
= Connection Points
Red = Center Brake
Red = Brake
Orange = Running
Vehicle Brake
Vehicle Running
*For Single function on Brake, Omit the Dual Converter. Cap any unused wires to prevent shorting.
*Dual Converters may be applied to left and right turn sections for low high operation. Scenario not shown.
Red = Left Turn
Universal Integrated Run/Turn or Run/Brake/Turn TruFLEX® 3 section Red/Red/Red
Yellow = Right Turn
*For Single function on Brake, Omit the Dual Converter. Cap any unused wires to prevent shorting.
Installation Instructions - Page 5
Questions? Call us at: 1 (800) 382-1388 M-TH 8:30AM-5:30PM / FR 9:30AM-5:30PM EST
07-2017
TFDC5S TFDC10S TFDC15S TFDC20S TFDC25S
TFDC30S TFDC35S TFDC40S TFDC75S
Black = Left LED Grounds Black = Right LED Grounds
Vehicle Ground
TruFLEX® Dual Color Amber/Red LEDs, in smoked tube
Vehicle Left Turn
Vehicle Right Turn
Yellow = Left Turn LEDs
Yellow = Right Turn LEDs
Red = Right Red LEDs
Red = Left Red LEDs
Orange = Left
Low Running
Orange = Left
Low Running
Vehicle Brake
-both
Vehicle Running
Part Numbers:
= Connection Points
Dual Color Technology - Hi Contrast Amber LEDs over­ride the Red when Vehicle Turn Signal is engaged.
Use weatherproof splice connectors or Posi-tapsfor connections or solder wire connections.
Make sure to insulate solder connections with heat shrink tubing or electrical tape.
*Diagram Shows wiring as Run/Brake/Turn with TFC Dual Converter.
*2 Units are required for left and right turns.
*For Single function on Brake, Omit the Dual Converter. Cap any unused wires to prevent shorting.
TruFLEX® Dual Color 2 Section 50/50 split Amber/Red (Run/Brake/Turn)
Part Numbers:
Left Turn Brake Right Turn Brake
Black = LED Ground
Yellow = Left Turn
Red = Brake
Black = LED Ground
Yellow = Right Turn
Red = Brake
2 Section Amber/Red TFDC50S TFDC70S TFDC90S TFDC110S
Vehicle Ground
Use weatherproof splice connectors or Posi-tapsfor connections or solder wire connections.
Make sure to insulate solder con­nections with heat shrink tubing or electrical tape.
Vehicle Left Turn
Red = Vehicle Brake
Vehicle Brake
= Connection Points
Vehicle Running
Orange = Running Low intensity
TFC Dual
Converter
Vehicle Ground
Vehicle Right Turn
TFC Dual
Converter
Note: Only (1) dual converter required for these parts.
Installation Instructions - Page 6
Questions? Call us at: 1 (800) 382-1388 M-TH 8:30AM-5:30PM / FR 9:30AM-5:30PM EST
06-2016SM
Universal Integrated Run/Turn or Run/Brake/Turn TruFLEX® 2 section Red/Red
Left Brake/turn Right Brake/turn
TruFLEX® TF110RR 2 Section 50/50 split Red/Red (Brake/Turn Only)
Internal Board Split
Black = Left Turn Ground
Purple = Left Turn/Brake
Brown = Right Turn/Brake
Black = Right Turn Ground
Left Brake/turn Right Brake/turn
TruFLEX® TF110RR 2 Section 50/50 split Red/Red (Run/Brake/Turn w/converters )
Internal Board Split
Black = Left Turn Ground
Purple = Left Turn/Brake
Brown = Right Turn/Brake
(For use on Vehicles with Integrated Brake and Turn Signals)
Black = Right Turn Ground
1
TFC Dual
Converter
1
Vehicle Ground
Vehicle Ground
Vehicle Left Brake/Turn
Vehicle Running
Vehicle Right Brake/Turn
Orange = Running Low intensity Orange = Running Low intensity
Red = Brake/turn
Red = Brake/turn
Vehicle Ground
Vehicle Left Brake/Turn
Vehicle Right Brake/Turn
Vehicle Ground
(For use on Vehicles with Integrated Brake and Turn Signals)
Use weatherproof splice connectors or Posi-tapsfor connections or solder wire connections.
Make sure to insulate solder connections with heat shrink tubing or electrical tape.
Part Number:
TF110RR
= Connection Points
Use weatherproof splice connectors or Posi-tapsfor connections or solder wire connections.
Make sure to insulate solder connections with heat shrink tubing or electrical tape.
*Diagram Shows wiring as Run/Brake/Turn with
TFC Dual Converter.
Part Number:
TF110RR
= Connection Points
Loading...