Cusam CS-200BV-1, CS-200BV-4, CS200BV-4ID, CS-200BV-3, CS-200BV-5 User Manual

...
www.cusamintercom.com
0
CODING INTERCOM
USER’S MANUAL
www.cusamintercom.com
1
Contents
Section Description page Ⅰ、System instruction ------------------------------------------2-6
Main Products---------------------------------------------2-3 Description of indoor phone-------------------------------4
Description of Door station--------------------------------5 System features----------------------------------------------6
Ⅱ、Technical parameter-------------------------------------------6 Ⅲ、Code setting--------------------------------------------------7-9 Ⅳ、Use method and problem dealing------------------------10-14 Ⅴ、System schematic and wiring diagram-----------------15-17 Ⅵ、Door station setting order------------------------------------18 Ⅶ、User’s operational order--------------------------------------19 Ⅷ、Wrong code form----------------------------------------------19 Ⅸ、Entrance guard setup instructions-----------------------20-21 Ⅹ、Attentions---------------------------------------------------21-23
www.cusamintercom.com
2
Ⅰ、System instruction
Coding video and audio intercom system mainly consists of the door station, the module, indoor phones, the power source and so on, which is extremely suit for the high building.
Main Products
Door station
www.cusamintercom.com
3
Indoor phones
www.cusamintercom.com
4
Description of indoor phone
Location
Description
Function
1
4/7Indoor phone Screen
Identify Visitor
2
Power Light
Indicates Power On
3
Monitor Button
View Picture On Indoor phone
4
Call/Alarm(Alarm may choose )
Button
Activate Alarm
5
Unlock Button
Operate Electric Door Lock
6
Microphone
Speak to Visitor
7
Talk Button
Telephone conversation
8
Brightness
Adjust brightness of Indoor phone
9
Contrast Adjustment
Adjust contrast of Indoor phone
10
Receiver
Listen to Visitor
11
Volume Adjustment
Adjust Volume of Indoor phone
www.cusamintercom.com
5
Description of Door station
Location
Description
Function
1
Camera Lens
Sends Picture To Monitor
2
Night Vision Light
Illuminates Area In Darkness
3
Speaker
Enables You To Speak To Visitor
4
Door Bell Button
Pressing Gives Ding Dong Sound
5
Microphone
Enables Visitor To Speak To You
www.cusamintercom.com
6
▲ System features
LED inside the door station provides a clear picture even at night.
It is with all functions and features that video and audio coding intercom system have
Video indoor phones can be installed with audio indoor phones together, which is very flexible and convenient.
Ⅱ、Technical parameter
·Working voltage:DC10.8V~16V
·The undistorted power of output:
The main channel: 5mw min The reply channel: 100mw min
·Frequency response:300~3400HZ±3db
·Environment temperature :-40℃ to +70℃
·Humidity:45% to 95%
·Working current of camera:500mA±20mA
·Camera:1/3″ CCD
·Definition:380 TV Line
www.cusamintercom.com
7
Ⅲ、Code setting
1. Press**00,XXXX and enter into the coding state.(the original
password of the manager is 2098)
2. Press **02 to change the coding state into “0”.
3. Using order code **16 to set the number of dialing,it depends on
the floors (If it is over 9 floor,please use mixed dialing. Set code “7”,you
can dial three and four number mixly). Please press "#" to exit programming.
The quick establishing of the extension phone number: (Recommendation )
The door station provides a quick order "**41" if the room number
encoding method conforms to the rule of table 1, Just do as follows:press **00, XXXX (manager password), **41, then it will come to the programming rule as table one does.
The door station provides a quick order "**42" if the room number
encoding method conforms to the rule of table 2,
www.cusamintercom.com
8
The door station provides a quick order "**43" if the room number
encoding method conforms to the rules of table 3.Use order “**40” to
eliminate the comparative table of the module address and the room number".
The manipulating setting of the extension phone number: press **15
and come up with Y011 after completes steps 1, 2, 3 (Y stands for the address, the 2nd and 3rd figure stand for the coding site, and the 4th figure is the room number).Entering three numerals if you want to
revise the address, and press the key "*" if you don’t want to. It’ll show
four numerals after finishing the above steps.Please enter four numerals to revise (namely room number), press "*" if do not revise (namely examination), and then it will demonstrate the next encoding address. If the four figures have been in table (namely
repetition), and it’ll show the repetitious number
address. Then please enter 0000,that mean you don't use this address.
The module(see the picture in the right corner),
the address of module ranges from 0101 to 9904.
www.cusamintercom.com
9
Namely the coding sites are 01 to 99 (namely floors are 01 to 99), room number are 01 to 04. The first 8,421 is decimal and the latter 8,421 is the single. There are eight pairs of two sides contact pin.
Coding site 01 (the first floor): the block of short-circuits should be
inserted in the single 1 contact pin
Coding site 03 (the third floor): the block of short-circuits should be
inserted in the single 1 and 2 contact pin.
Coding site 06 (the sixth floor): the block of short-circuits should be inserted in the single 2 and 4 contact pin. Coding site 19 (the nineteenth floor): the block of short-circuits should be inserted in the single 1 and 8 and decimal 1 contact pin.
The room number 01-04 should be inserted in R01, R02, R03, R04 accordingly.
(for example) If the room number you want is 1301, insert the block of short-circuits to the single 1 and 2 and decimal 1,and the room number cut over to R01 then. The comparative table of room number and module address, see details in 6,and 7 pages,
www.cusamintercom.com
10
Ⅳ、Use method and problem dealing
1. The visitor can input the room number directly when he /she comes.
Press “#” to eliminate and re-input when you input wrong number, then the extension telephone will have the ring sound. meanwhile, the indoor phone displays the image automatically. Pressed the unlock button which control the electronic lock of the front gate after confirming the visitor. And the image will shut-off automatically after hanging off the phone. If the coding is 3 and 4 dialing mixly, for example: you can dial 101 or 0101 either.
2. The gate will be shut off by the closing machine automatically after
the visitor entering into the door.
3. The system may maintain the work by the reserving power source
when the power is off,
4. The resident can press "monitor" if he wants to monitor the
situation downstairs, and the picture of downstairs will show on the screen of the indoor phone in the room, it will be shut-off automatically about 15 seconds later.
5. There are three potentiometers in the door station, which are “the
www.cusamintercom.com
11
mainframe”, ” the extension phone” and "the balance". "The mainframe"
uses to adjust the volume of the door station; "The extension phone" uses to
adjust the volume of indoor phones, which limits in some range, and don’t
attempt to adjust the volume of indoor phone and break potentiometer; "The balance" use to eliminate the sidetone.
6. The connection of the wires must be correct exactly, otherwise it
will affect the normal work of the whole system. The wrong connection of the main wire may cause modules in all floors cann't code and ring. When you come across this kind of problems,please separate the majority of modules and debug one by one until finding out the failure.
7. When the door station call indoor phones,and it sends two "di , di "
sound , that mean it cann't detect the indoor phone, If it sends three "di, di, di " sound, that mean the wire of the indoor phone is short-circuits. When the door station call all indoor phones,they are unnormal or no sound,then it maybe the failure of main wire.
8. If the indoor phones don’t work when it is picked up or hanged off;
the volume is too low or the indoor phones in higher floors cann’t unlock the gate etc.please check up that the section area of main line or branch line is too slim or not.
www.cusamintercom.com
12
Table 1, comparative table of initialization room number and extension phone address (the 1st kind)
(module address) (coding
site)
(room
number)
(module
address)
(coding
site)
(room
number)
(module
address)
(coding
site)
(room
number)
(module
address)
(coding
site)
(room
number)
01.01
0101
05.01
0501
09.01
0901
13.01
1301
01.02
0102
05.02
0502
09.02
0902
13.02
1302
01.03
0103
05.03
0503
09.03
0903
13.03
1303
01.04
0104
05.04
0504
09.04
0904
13.04
1304
02.01
0201
06.01
0601
10.01
1001
14.01
1401
02.02
0202
06.02
0602
10.02
1002
14.02
1402
02.03
0203
06.03
0603
10.03
1003
14.03
1403
02.04
0204
06.04
0604
10.04
1004
14.04
1404
03.01
0301
07.01
0701
11.01
1101
15.01
1501
03.02
0302
07.02
0702
11.02
1102
15.02
1502
03.03
0303
07.03
0703
11.03
1103
15.03
1503
03.04
0304
07.04
0704
11.04
1104
15.04
1504
04.01
0401
08.01
0801
12.01
1201 … …
04.02
0402
08.02
0802
12.02
1202
99.02
9902
04.03
0403
08.03
0803
12.03
1203
99.03
9903
04.04
0404
08.04
0804
12.04
1204
99.04
9904
www.cusamintercom.com
13
Table 2 ,comparative table of initialization room number and extension phone address (the 2nd kind)
(module address)
(coding
site)
(room
number)
(module
address)
(coding
site)
(room
number)
(module
address)
(coding
site)
(room
number)
(module
address)
(coding
site)
(room
number)
01.01
0101
05.01
0901
09.01
1701
13.01
2501
01.02
0102
05.02
0902
09.02
1702
13.02
2502
01.03
0201
05.03
1001
09.03
1801
13.03
2601
01.04
0202
05.04
1002
09.04
1802
13.04
2602
02.01
0301
06.01
1101
10.01
1901
14.01
2701
02.02
0302
06.02
1102
10.02
1902
14.02
2702
02.03
0401
06.03
1201
10.03
2001
14.03
2801
02.04
0402
06.04
1202
10.04
2002
14.04
2802
03.01
0501
07.01
1301
11.01
2101
15.01
2901
03.02
0502
07.02
1302
11.02
2102
15.02
2902
03.03
0601
07.03
1401
11.03
2201
15.03
3001
03.04
0602
07.04
1402
11.04
2202
15.04
3002
04.01
0701
08.01
1501
12.01
2301 … …
04.02
0702
08.02
1502
12.02
2302
49.04
9802
04.03
0801
08.03
1601
12.03
2401
50.01
9901
04.04
0802
08.04
1602
12.04
2402
50.02
9902
www.cusamintercom.com
14
Table 3 comparative table of initialization room number and extension telephone address (the 2nd kind)
(module address)
(coding
site)
(room
number)
(module
address)
(coding
site)
(room
number)
(module
address)
(coding
site)
(room
number)
(module
address)
(coding
site)
(room
number)
01.01
0101
05.01
0301
09.01
0501
13.01
0701
01.02
0102
05.02
0302
09.02
0502
13.02
0702
01.03
0103
05.03
0303
09.03
0503
13.03
0703
01.04
0104
05.04
0304
09.04
0504
13.04
0704
02.01
0105
06.01
0305
10.01
0505
14.01
0705
02.02
0106
06.02
0306
10.02
0506
14.02
0706
02.03
0107
06.03
0307
10.03
0507
14.03
0707
02.04
0108
06.04
0308
10.04
0508
14.04
0708
03.01
0201
07.01
0401
11.01
0601 … …
03.02
0202
07.02
0402
11.02
0602
126.02
6306
03.03
0203
07.03
0403
11.03
0603
126.03
6307
03.04
0204
07.04
0404
11.04
0604
126.04
6308
04.01
0205
08.01
0405
12.01
0605
127.01
6401
04.02
0206
08.02
0406
12.02
0606
127.02
6402
04.03
0207
08.03
0407
12.03
0607
127.03
6403
04.04
0208
08.04
0408
12.04
0608
127.04
6404
www.cusamintercom.com
15
Ⅴ、System schematic and wiring diagram
1System structure schematic drawing
www.cusamintercom.com
16
2System wiring diagram
www.cusamintercom.com
17
www.cusamintercom.com
18
Ⅵ、Door station setting order
CODE
ORDER
DIGIT CODE
Significance
remark
*000
XXXX
The manager operates the lock
**00
XXXX
(4 passwords)
Confirmating the manager
password
It should be confirm the manager password first
before using the order from **00 to **19
(Tacitly approves No, is 2098)
**01
XXXX
(4 new passwords)
Revising the manager password
**02
000X
Revising the coding method
the efficient number are 1.2.3.6.7.8.9.0
”0” is the onmipotent coding (Tacitly approves
No, is 2)
**03
0XXX
Revising the ringing time
001-255seconds(Tacitly approves No, is 60)
**04
0XXX
Revising the Dialogue time
001-255seconds(Tacitly approves No, is 120)
**05
000X
Revising the ring types
0-9(0 is the “dingdong” sound, and 1-9 is the
phone sound) (Tacitly approves No, is 0)
**06
0XXX
Revising the waiting time after
ringing
001-255seconds(the user also can answer the
phone after the ring stopped) (Tacitly approves
No, is 1)
**07
0XXX
Revising the time of operating
lock
001-255seconds(unit is 0.2 second, tacitly
approves No, is 5,namely the time of unlocking
is 1 second)
**08
0XXX
Revising the waiting time after
opening the door
001-255seconds(the talking time after opening
the door) (Tacitly approves No, is 20)
**09
000X
demonstration type at standby
state
0-9 (Tacitly approves No, is 1)(0-off,1-9 are
demostrating)
**10
000X
Controlling thecode tube to
demonstrate or to slake when
picking up phone
0-1(Tacitly approves No, is 1)
0 is to slake
1 is to demonstrate
**11
0XXX
revising the alarm time
000-255seconds,000-close the alarm function.
(Tacitly approves No, is 000)
**12
0XXX(Serial
number)
XXXX(password)
Manager revising the unlock
password of users
The scope of Serial number:000-239
password cancelling:0000
**13
XXXX XXXX
establishing eight public
password to open locks
password cancelling:0000
**15
YXXX(module
address)
edits comparative table of "
onmipotent coding "
Reference the comparative table of " onmipotent
coding "
**16
000X
choosing the " dialing digit"
Only suit for the onmipotent coding the
effective number is 1.2.3.4,(Tacitly approves
No, is 3)
**17
000X
Which digit to demonstrate a
letter
The effective digit is 1-4,or the tacitly approves
demonstrate no letter
**18
XXXX(room No.)
Checking the room number of
onmipotent coding
Checking the module address of the room
number in table “onmipotent coding”
**19 Restoring factory setting
Restoring the digits **02-**11,**16-**17 are
the factory tacitly approves No,
www.cusamintercom.com
19
Ⅶ、User’s operational order
Order name
Order code
Following code
Remark
The user revises the
password of
unlocking
**20
0XXX(Serial number) XXXX(old password)
8535(confirm code)
XXXX(new password)
Serial number’s
Range of validity
001-239
The user password
operates the lock
*XXX (Serial
number)
XXXX(password)
Serial number’s
Range of validity
001-239
Public password
operates the lock
*250
XXXX XXXX
(eight password)
Ⅷ、Wrong code form
Mistake
code
Significance
Wrong
code
Significance
E01
Overtime
mistake
E07
The extension phone or the main line
open circuit
E02
Order mistake
E08
The extension phone or the main line
short-circuits
E03
Password
mistake
E09
Scope mistake of module address
when coding in onmipotent coding
E04
Data-in over
scope
E10
The repetition of room number when
coding in onmipotent coding
E05
Room number
mistake
E11
Can’t find the room No. in table
onmipotent coding
E06
Forbidden call
E12
The data is unable to transmit
www.cusamintercom.com
20
Ⅸ、Entrance guard setup instructions
Refer to the below circle(the black short circuit block) 1 Set two Management Card (adding card and deleting card): First. Switch off the power put the black short-circuit block
cover on 0 turn on the power a bibi sound Red ,green light flash alternately. Second, Take a blank card on the above of black short circuit block for 1 second a bibi sound successful, remark this is an adding card. Take another blank card on the above of black short circuit block for 1 second a bibi sound successful, named it is a deleting card. Third. Put the short circuit block cover on 1. Switch on the power.
2, adding user cards: put an adding card on the above of black short-circuit block for 1 second a bibi sound red and green light flash alternately put a user card on the above of black short-circuit block for 1 second put an adding card on the above of black short-circuit block for 1 second a bibi sound setting successfully. (One user card can be set only once during above operation)
www.cusamintercom.com
21
3, deleting user cards: put an deleting card on the above of black short-circuit block for 1 second a bibi sound red and green light flash alternately put any user card on the above of black short-circuit block for 1 second, it can be continuously put a deleting card on the above of black short-circuit block for 1 second a bibi sound set successfully.
Ⅸ、Attentions
The video and audio indoor extension phone can be used both in networking and non-networking system.It's good for non-networking upgrading to networking system.
If the door station promotes to the networking system, then just replace the control chip of the non- networking door station
The non- networking system promoting to the networking system needn’t to change the wiring of the original unit, and the networking (networking system is called floor controller) and the non- networking system have the same wiring from the door station to the module and indoor phones.
The wiring request of non- visible partial
1. The section area should be bigger than 0.3mm2 ,if the length of
master line is less than 50M
www.cusamintercom.com
22
2. The section area should be bigger than 0.5mm2 ,if the length of
master line is between 50M and 100M
3. The section area should be bigger than 0.15mm2 ,if the length of
branch line is less than 20M
4. The section area should be bigger than 0.3mm2 ,if the length of
branch line is between 20M and 50M
5. The wire that from the power source to the door station and door
station to locks, the section area of which should be bigger than 0.5mm2, and the length have to be less than 15M, otherwise should enlarge the area of wire
the possible problems if the wiring does not conform to the request
1. If the section area of mian line or branch line is too slim, it may
cause the indoor phones don’t work when it is picked up or hanged
off,can’t unlock the gate,or the low volume of indoor phones and things
like that.I
2. The section area of the wire that from power to door station and
door station to electronic lock is too slim.then it may cause the indoor phone can’t unlock the door. the wiring request of visible partial
www.cusamintercom.com
23
Visible partially has two electric wires, one is for the surveillance requests (M), the other is for the video coaxial cable (vi). The video coaxial cable system uses SYV75-3, and should pay attention that the outer
layer shield cann’t use as the wire to supply power, otherwise it possibly
causes the power source and undulation interfering picture
The section area should be bigger than 0.5mm2 when the length of
electric wire is less than 30M,
The section area should be bigger than 0.75mm2 when the length of
electric wire is less than 50M
The section area should be bigger than 1.0mm2 when the length of
electric wire is less than 80M,
The section area should be bigger than 1.5mm2 when the length of
electric wire is more than 80M,
General speaking,every 4 to 8 floors should add a power source for
video, at this time,you can let up the section area of wire suitably.
There is no special request that the line of surveillance requested to the
section area of wire.
The unlocks circuit of this machine mates to the ordinary electric controlled lock, if it mate to the electric lock driving by weak signal like magnetic force lock.,then it may causes to unlock by mistake.Now you should connect a relay first,then use the connect of relay to drive the weak signal lock.
Loading...