Curv CT12060, CF6060, CT6060, CF15060, CM50 Installation & Operating Instructions Manual

...
The Smarter Way
To Heat Your Home
Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters
Curv-infrared.com
Before installing this heater, the user should determine the suitability of the heater and its intended use. Cürv360 Limited shall not be liable for any direct, indirect special, incidental or consequential damages resulting from improper product use.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist.
IMPORTANT! THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR
FUTURE REFERENCE
Failure to observe these instructions will invalidate the warranty. Do not disassemble the Cürv heater or this will invalidate the warranty.
Warning
To reduce the risk of re, electric shock or injury:
1. This heater must be disconnected from the power during installation or when replacing.
2. Check each heater, plug and cable are free from damage before installation.
3. In order to avoid overheating and potential re hazard, do not cover the
heater with insulating material or similar material under any circumstances.
4. Do not touch the heater when in use. Cürv infrared heaters have a surface temperature of around 85°c and prolonged contact with the heater will cause burns
and injury.
5. Do not operate the heater if the cable or plug is damaged or after the heater malfunctions, or if it has been dropped or damaged.
6. For Cürv Towel Rails and Mirrors handle with care and avoid damaging the glass. Do not use the heater if the glass is damaged; disconnect the heater and do not use again.
7. This heater must only be used for internal use within a property.
8. Children should be kept away and should not be left unsupervised around the heater.
9. Ensure the heater is isolated at the mains when cleaning.
10. Important: Cürv infrared heaters are designed for use with an AC voltage between 220-240 volts, 50 Hz AC
11. Important: the heater must be mounted on a non-ammable surface.
Safety Precautions
However, installation in potentially wet or humid rooms such as bathrooms must be carried
out by a suitably qualied installer and comply with local electrical safety requirements. Installation must be such that:
The heater must not be able to become detached from the ttings and fall into a
bath, shower, swimming pool or other water container.
Switches and other controls cannot be touched by a person in the bath or shower.
If in doubt, do not install. Cürv360 Limited shall not be liable for any loss, damage or injury caused or resulting from inadequate tting or incorrect placement of heaters close to water
sources.
Installation Position
Cürv infrared heaters heats objects by transferring energy directly from the heater into the object. Therefore, consider placing the heater where it will not be obstructed by objects like furniture or where it cannot eectively radiate the heat. Objects placed in front of the heater will heat up and can prevent eective heat being dispersed into the room and could cause the heater to overheat and will void the warranty. Avoid placing the heater opposite large
windows or open doorways.
Only the Cürv Towel Rails and Cürv Mirrors are rated to IP44 enabling them to be located
within a splash zones in a bathroom (Zone 2).
IP Protection
IP44 - Cürv Towel Rails IP44 - Cürv Mirrors IP50 - Cürv & Flat Heaters
All Installations should only be carried out by suitably qualied person or competent
persons.
If the Cürv Infrared Heater is being hard wired (so the plug is removed), the electrical installation should only be carried out by suitably qualied personnel.
Wiring to this appliance must be connected in accordance with the relevant national electrical safety standards. It is a Class 1 appliance and must be earthed.
When placed in public areas, installation must comply with relevant local electrical standards. For certain public buildings like schools and care homes the heaters must be installed
according to the specic legislation for these types of buildings.
The electrical supply to the heater should be connected to a circuit protected by a fuse and adequate circuit protection which comply with the latest building regulations and earth arrangements, to ensure the heater will disconnect from the supply if there is a fault.
Colour coding used in the supplied mains cable:
BROWN wire is to be connected to LIVE (‘L’) BLUE wire to NEUTRAL (‘N’) GREEN/YELLOW wire to EARTH (‘E’).
Ensure mains power is OFF before commencing an installation involving xed wiring.
Ensure that the power cable is not coiled. Do not place excess cable on the rear of the heater.
Electrical connections must not be made behind the heater. Do not install the Infrared Heater immediately below a socket.
DO NOT drill through the heater as this will cause irreparable damage. DO NOT connect a heater that is damaged to the electricity.
When installing your Cürv Infrared Heater only use the supplied mounting bracket and install in accordance with the installation guide. Cürv360 Limited cannot accept responsibility for
damage, loss or injury caused by, or resulting from incorrectly installed heaters. Cürv360
Limited will not assume liability for consequential loss however caused.
*Heater wattage output can vary due to the voltage with in you property.
Caution
Before attempting to clean the heater, unplug the heater or isolate the heater from the electrical supply and allow it to completely cool down. DO NOT immerse the Cürv Infrared heater in water. Clean the heater with a damp cloth. For mirror models and towel rails glass cleaner can be used. Never use a wet cloth. When clean, dry the surfaces with a dry cloth.
Wait until the heater is completely dry before use.
DO NOT apply abrasive materials, solvents or solvent wipes to the surface as this can cause irreparable damage.
DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing
so will void your warranty.
Cleaning
Warranty
You can Register your Cürv infrared heater here: www.curv-infrared.com/warranty Please register your product within the rst 3 months to validate your warranty
Within fteen years from date of purchase Cürv360 Limited will repair or replace the heater element where the fault is due to defects in materials or workmanship. All electronic components of this heater will be replaced with in the rst ve years from purchase in event
of failure. In the event of a warranty claim please consult your local dealer and return the heater together with proof of purchase.
A prerequisite for validity of the warranty is use at the specied supply voltage of the heater and use in accordance with the conditions specied in this manual. (Any further warranty or claims are excluded.)
Failure to register your warranty as per above will result in a twelve month warranty being granted for all components of the heater.
Curv Smart products require a WIFI enabled (2.4Ghz protocols 802.11b/g/n) router and
internet connection to access the smart hub. Curv cannot be held responsible for the quality or consistency of your internet connection and faults should be addressed with your provider. This Limited Warranty does not guarantee that the use of the Curv Smart products will be uninterrupted or error free.
The warranty covers the repair or replacement of the defective product only and Cürv360 Limited shall have no liability for installation costs or consequential loses however incurred.
Removing the serial number will void the warranty. The warranty will also be void if the heater has been tampered with or opened in any way.
The product identication label must be left on the panels where they can be accessed after
installation if necessary.
Cürv360 Limited will assume no responsibility for scratches on surface after rst use.
Cürv360 Limited cannot accept responsibility for damage, loss or injury caused by ingress of water or moisture, accidental damage, mishandling, external impact, adjustment by
unauthorised personnel or failure to follow the correct maintenance and safety precautions as stated in the manual. Refer to Cürv 360 limited warranty policy for full details.
www.curv-infrared.com/warranty
Heater Controls
Cürv Mirror Only
Fig 1. Wave hand under the Cürv Mirror to
turn the LED Lights ON / OFF
ON / OFF (LED Auto Light)
Fig 2. LED Lights O / ON (via sensor)
Fig 1. Fig 2.
Cürv Mirror / Towel Only
5 Amp Fuse
WIFI connection
Flashing green when pairing or searching
Solid green when paired
T Room Thermostat Connection
Solid green when pairing to room stat
Flashing green when communicating with
room stat
ON Switch
Heat on with WIFI and Room stat
functionality
OFF Switch
Heater O
BYPASS Switch
Heat On, no smart or thermostat control
Our heaters can be installed horizontally or vertically to suit your requirements. We supply a xing pack containing wall xings, mini level, drill bit and xing template.
To install horizontally x the bracket to the wall with the A pointing up. Ensure the xings on the rear of the heater are screwed into the screw holes marked A. See Fig 1.
To install vertically x the bracket to the wall with the B pointing up. Ensure the xings on
the rear of the heater are screwed into the screw holes marked B. See Fig 2.
Installation Guide
Fig 2. How the bracket will sit on the back of
the heater when xed to the wall horizontally.
Fig 1. How the bracket will sit on the back of
the heater when xed to the wall horizontally.
B
A
B
A
B
A
B
A
A
B
A
B
A
B
A
B
Step 1
Please remove transportation screws before installation. Place the bracket on the wall
centrally where you wish to install the heater then mark the xing holes or use the template
provided.
Step 2
Drill the holes with the drill bit supplied then use the correct wall xings to secure the bracket to the wall:
Step 3
Place your Cürv Infrared heater onto the bracket ensuring all it locks into place on the bracket. Please refer to Fig 1 and Fig 2 for help.
Heater Installation
Step 4
Remove any protective lm.
Step 5
Plug your heater in and switch on the power.
Fig 2. How the bracket will sit on the back of the
heater when xed to the wall horizontally.
Fig 1. How the bracket will sit on the wall before attaching the heater.
Fixings
Towel Rail Installation
Fixing Locations
Please use these measurements below or the template provided, to install for your Cürv Towel Rail.
( ) mark the xing points.
Fig 1. 1200 x 600 - CT12060 Fig 2. 600 x 600 - CT6060
20mm
20mm
300mm
680mm
200mm
Pairing set (PAIR)
Timer setting (PRG)
Current time set (TIME)
SET Select High (H), Medium (M) or Low (L)
heating mode.
Press and hold SET for 3 seconds for
frost/holiday mode.
Boost Mode.
x Cancel function / delete Heater
Quick press thermostat On / O
Long press to start the timer mode
+ Increase Temperature
scroll left Long press to switch to Celsius
- Decrease Temperature / scroll right
Long press to switch to Fahrenheit
Wireless Room Thermostat
(To Wake the thermostat, press any button)
Installing Wireless Room Thermostat
Install the Cürv Thermostat away from drafts, radiators, replaces, or direct sunlight or anything that would cause the temperature to be articially high or low. Do not x directly above the Cürv
heater.
Recommended installation height 1.5 metres when xing cradle to the wall:
To Pair the Wireless Room Thermostat
1. Install 4 x AAA batteries in the room thermostat. (Recommended Lithium Battery).
2. Press the T button on the side of the Cürv Heater that you want to pair for 2 seconds so
that it lights up green.
3. Press the until you reach the pair option.
4. Press Set.
5. Choose which number (which will be ashing in the bottom right of the screen) that you
wish to allocate the heater to by using the +/ - buttons.
6. Then press the to accept.
7. When the number stays on the screen the heater is now paired to the room thermostat.
8. To cancel pairing hold X for 4 seconds.
9. You can pair up to 8 heaters to one thermostat if required.
To Un-pair A Heater From A Room Thermostat
1. Press the until you reach the “PAIR” option.
2. Press Set.
3. Choose which heater number (this will be ashing in the bottom right of the screen)
that you wish to remove by using the +/ - buttons.
4. Then press the X to remove that heater.
To Set Date and Time
(Note. If you are using the Cürv Smart App the time and date will automatically be updated.)
1. Press the until you reach the “TIME” option.
2. Press Set.
3. Use ‘+’ and ‘-’ to select the Day.
4. Press .
5. Use ‘+’ and ‘-’ to select the Hour.
6. Press .
7. Use ‘+’ and ‘-’ to select the Minutes.
8. Press for 3 seconds to save
9. Press X to exit. (If no buttons are pressed for 10 seconds, it will automaticaly exit.)
To Program a heating Schedule
(Note. If you are using the Cürv Smart App the heating schedule will automatically be updated.)
1. Press the Button until you reach the “PRG” option.
2. Press Set.
3. Use ‘+’ and ‘-’ to select the Day.
4. Press .
5. Use ‘+’ and ‘-’ to select the ON Hour.
6. Press .
7. Use ‘+’ and ‘-’ to select the ON Minutes.
8. Press
9. Use ‘+’ and ‘-’ to set the Temperature.
10. Press .
11. Use ‘+’ and ‘-’ to select the OFF Hour.
12. Press .
13. Use ‘+’ and ‘-’ to select the OFF Minutes.
14. Press .
15. Repeat Until you have set your temperatures throughout the day.
16. Press “SET” and ‘+’ and ‘- to change the Day you wish to program.
17. Press to select and continue from stage 5.
18. Press for 3 seconds to save
19. Press and hold X to exit.
To Set the Child Lock (Safe Surface Temperature)
1. Press the + and - Buttons for 5 seconds.
2. The Lock symbol will now be displayed and the heaters surface will be locked so that.
it will not exceed 43°C.
3. To Unlock Press + and - for 5 seconds.
Boost Mode
1. Press set for 3 seconds to enter boost / sleep mode 30, 60 ,90 minutes.
2. Press + or - to set the temperature in boost.
3. SL ashes with the remaining time.
The Cürv App
To Control your Heater with the Cürv App please search “Cürv” in the App store and download the Cürv Infrared App.
5. Please enter the code and press next, then ll in you
details and register.
6. Log into your account using your telephone number .
and the password that you have just created.
1. Download the App.
2. Click on Register.
3. Enter your mobile phone number and press Get Code.
4. You will receive a text with a verication code.
Reset Your Password
1. Select Forgot Password? From the login screen.
2. Enter you telephone number.
3. Select Get Code.
4. You will receive a text with a Verication Code.
5. Enter the received Verication Code and
your new password.
6. Press next to conrm your new password.
1. You then need to pair the App with your WI-FI network
by pressing the Icon on the bottom menu bar.
2. Select your WI-FI SSID (router) then enter the password, then click ‘Connect’.
3. Press the button on your heater for 3 seconds until
it ashes. The heater is now in pairing mode.
4. Press ‘Next’ you can then select the “Curv_XXXXXX” heater
from your available WIFI connections. Return to the Cürv
APP and wait for pairing to complete.
5. Please set a name for the Cürv heater and set currency.
Then click “Connect” to complete the conguration.
Add A Heater
*Cürv Smart products require a WIFI enabled (2.4Ghz protocols 802.11b/g/n) router and internet connection to access the
smart hub. Cürv cannot be held responsible for the quality or consistency of your internet connection and faults should be
addressed with your provider. This Limited Warranty does not guarantee that the use of the Cürv Smart products will be
uninterrupted or error free.
CURV_XXXXXX
£
Devices Mac Address: 009569A794E2
Input Device Name
Create an area / room with 2 or more heaters
1. From the main menu page press + (in the top right- hand corner).
2. Give the group of heaters a name. You can also add a picture if you wish.
3. Press Save.
4. From your list of heaters in my devices select the heater you wish to move into the group swipe left to reveal menu then select move.
5. Select the area you created earlier in the menu and select OK.
6. Repeat this process for as many heaters you wish to add into this area and control all heaters together.
To allow multiple users to control the heater
1. Each user must create an account on their device.
2. From the origional device that paired the heaters, go into the heater control screen and press in the top right-hand corner.
3. Select share, this will display a QR code which can be scanned by the other device you wish to share the heater with.
4. On the device you wish to add the heater, select then press to scan the QR Code from the device with the origional account.
5. Please conrm you wish to add the shared heater. This
will now show in both accounts.
To program a heating scheldue
1. Select the heater or group of heaters you wish to set up the schedule.
2. Press (in the top right corner) and selecting timer
from the drop-down menu.
3. Press the + to add a schedule.
4. Set your start time.
5. Set your end time.
6. Select the days you wish to repeat this schedule.
7. Select the required temperature.
8. Then save.
9. You can repeat this process to schedule dierent
heating temperatures throughout the day.
Cürv Heater
Cürv Heater
Cürv Heater
Cürv Heater
Statistics Features
Select to set up the Currency, Electric Charge, Peak Rate (start time – end
time), O Peak rate (start time – end time).
To previous page.
Share heaters and program time schedules.
ON / OFF Turns the heater on and o.
TIMER Turns the heater in timer mode (if scheduled).
C / F Switch temperature display between °Cto°F.
BOOST Press boost for a 30, 60 or 90 minute heating boost.
ECOMODE Switch between Low, Medium and High heating mode.
Anti-freeze mode (will not go below 5°C).
Press the child lock button for 3 seconds to lock the
heaters surface temperature to a maximum of 43 degrees.
Controling your heater.
From the Statistics menu, you can view your monthly.
usage in kWh and costs to run your heating.
Menu Bar
1. Modify your password. 2. Displays your app version. 3. Exit App.
Set up new heaters, WIFI and add a shared heater.
Heater main control menu.
Heater Control Features
Cürv Heater
*All Cürv application screenshots may dier depending on device or application version.
Indicates the WIFI signal strength
v1.1
Curv360 Limited, Lakes Court, Newborough Road, Burton on Trent, DE13 9PD
Manufactured in China curv-infrared.com
Loading...