CP Form CFD-AD CP © 2006
5350 Campbells Run Road • Pittsburgh, PA 15205-9738
800-833-5005 • Tel:
412-787-9750 • Fax: 412-787-3665
CFD AIR DOORS
Commercial Front Door: CFD-TQ SERIES – 1 Speed
MODEL CFD-TQ-2-36-1 CFD-TQ-2-42-1 CFD-TQ-2-48-1 CFD-TQ-2-60-1 CFD-TQ-3-60-1
Nozzle Width (in.) 36 42 48 48 60
Max. Velocity (fpm) 3000 3000 3000 3000 3000
Air Volume (scfm) 1480 1510 1500 1600 2310
No. of Motor(s) @ H.P. 1@
3
⁄
4
1@3⁄
4
1@3⁄
4
1@3⁄
4
1@3⁄
4
Power Rating (kw) .51 .33 .52 .31 .40
Outlet Vel. Uniformity (%) 90 87 65 45 80
Sound Level 58 dBA 58 dBA 58 dBA 58 dBA 58 dBA
Shipping Wt. Unheated (lbs.) 70 80 82 96 105
Electric Heater: Cap. (MB/hr) 25.598 25.598 34.130 34.130 51.195
Capacity (kw) 7.5 7.5 10 10 15
Temp. Rise (°F) 16 16 21 20 20
Ship. Wt. Heated Mod. (lbs.)
75 85 87 102 115
Commercial Front Door: CFD-HH SERIES – 3 Speed
MODEL CFD-HH-2-36-1-3S CFD-HH-2-42-1-3S CFD-HH-2-48-1-3S CFD-HH-2-60-1-3S CFD-HH-3-60-1-3S
Nozzle Width (in.) 36 42 48 48 60
Max. Velocity (fpm)
*
1800/2200/ 2800 1800/ 2200/ 2800 1800/2200/ 2800 1800/2200/ 2800 1800/2200/ 2800
Air Volume (scfm) 1224/1490/1900 1350/1630/ 2090 1360/1642 /2105 1380/1691 /2168 2110/ 2587/ 3317
No. of Motor(s) @ H.P. 1@1⁄
2
1@1⁄
2
1@1⁄
2
1@1⁄
2
1@1⁄
2
Power Rating (kw)* 0.23/ 0.27/0.34 0.26/ 0.30/ 0.37 .0.33/ 0.42/ 0.49 0.33/ 0.42/0.56 0.53/0.68/ 0.90
Outlet Vel. Uniformity (%) 90 87 65 45 80
Sound Level in dBA* 51/ 56 /58 51/ 56 /58 51/ 56 /58 51/ 56 /58 51/ 56 /58
Shipping Wt. Unheated (lbs.) 70 80 82 96 105
Electric Heater: Cap. (MB/hr) 25.598 25.598 34.130 34.130 51.195
Capacity (kw) 7.5 7.5 10 10 15
Temp. Rise (°F)* 19/ 16/ 12 17/ 14/ 11 23/19/ 15 23/ 19/ 15 22/ 18/ 14
Ship. Wt. Heated Mod. (lbs.)
75 85 87 102 115
AIR DOOR MODELS
CFD-TQ SERIES
CFD-HH-3S SERIES
For FRONT ENTRANCES
and PATIO OPENINGS
For doors wider than 60''
apply multiple units
Standard Amps for Amps for
Motor Voltages
1
/2 Motor3/4 Motor
120, 1ø, 60 hz 7.2 7.5
208, 1ø, 60 hz 4.0 3.8
240, 1ø, 60 hz 4.0 3.8
460, 1ø, 60 hz N/A 1.8
AMP DRAW OF ELECTRIC HEAT
Voltage
7.5 kw 10 kw 15 kw
208v 1ø - 60 hz 36.1 48.0 72.0
240v 1ø - 60 hz 31.4 41.7 62.5
208v 3ø - 60 hz 20.9 27.8 41.6
240v 3ø - 60 hz 18.1 24.1 36.1
480v 3ø - 60 hz 9.0 12.0 18.0
Note: When amp draw of motors and heaters are
in excess of 48 amps, two power supplies are required.
*
3 Speed Rating @ Low / Medium /High
Dimensions on
Reverse Side