Curtron CFD-TQ-2-36-1, CFD-TQ-2-42-1, CFD-TQ-2-48-1, CFD-TQ-2-60-1, CFD-TQ-3-60-1 User Manual

...
CP Form CFD-AD CP © 2006
5350 Campbells Run Road • Pittsburgh, PA 15205-9738
800-833-5005 • Tel:
412-787-9750 Fax: 412-787-3665
CFD AIR DOORS
Commercial Front Door: CFD-TQ SERIES – 1 Speed
MODEL CFD-TQ-2-36-1 CFD-TQ-2-42-1 CFD-TQ-2-48-1 CFD-TQ-2-60-1 CFD-TQ-3-60-1
Nozzle Width (in.) 36 42 48 48 60
No. of Motor(s) @ H.P. 1@
3
4
1@3⁄
4
1@3⁄
4
1@3⁄
4
1@3⁄
4
Power Rating (kw) .51 .33 .52 .31 .40 Outlet Vel. Uniformity (%) 90 87 65 45 80 Sound Level 58 dBA 58 dBA 58 dBA 58 dBA 58 dBA Shipping Wt. Unheated (lbs.) 70 80 82 96 105 Electric Heater: Cap. (MB/hr) 25.598 25.598 34.130 34.130 51.195
Capacity (kw) 7.5 7.5 10 10 15 Temp. Rise (°F) 16 16 21 20 20
Ship. Wt. Heated Mod. (lbs.)
75 85 87 102 115
Commercial Front Door: CFD-HH SERIES – 3 Speed
MODEL CFD-HH-2-36-1-3S CFD-HH-2-42-1-3S CFD-HH-2-48-1-3S CFD-HH-2-60-1-3S CFD-HH-3-60-1-3S
Nozzle Width (in.) 36 42 48 48 60
Max. Velocity (fpm)
*
1800/2200/ 2800 1800/ 2200/ 2800 1800/2200/ 2800 1800/2200/ 2800 1800/2200/ 2800 Air Volume (scfm) 1224/1490/1900 1350/1630/ 2090 1360/1642 /2105 1380/1691 /2168 2110/ 2587/ 3317 No. of Motor(s) @ H.P. 1@1⁄
2
1@1⁄
2
1@1⁄
2
1@1⁄
2
1@1⁄
2
Power Rating (kw)* 0.23/ 0.27/0.34 0.26/ 0.30/ 0.37 .0.33/ 0.42/ 0.49 0.33/ 0.42/0.56 0.53/0.68/ 0.90
Outlet Vel. Uniformity (%) 90 87 65 45 80 Sound Level in dBA* 51/ 56 /58 51/ 56 /58 51/ 56 /58 51/ 56 /58 51/ 56 /58 Shipping Wt. Unheated (lbs.) 70 80 82 96 105 Electric Heater: Cap. (MB/hr) 25.598 25.598 34.130 34.130 51.195
Capacity (kw) 7.5 7.5 10 10 15 Temp. Rise (°F)* 19/ 16/ 12 17/ 14/ 11 23/19/ 15 23/ 19/ 15 22/ 18/ 14
Ship. Wt. Heated Mod. (lbs.)
75 85 87 102 115
AIR DOOR MODELS
CFD-TQ SERIES CFD-HH-3S SERIES
For FRONT ENTRANCES and PATIO OPENINGS
For doors wider than 60'' apply multiple units
Standard Amps for Amps for
Motor Voltages
1
/2 Motor3/4 Motor
120, 1ø, 60 hz 7.2 7.5
208, 1ø, 60 hz 4.0 3.8
240, 1ø, 60 hz 4.0 3.8
460, 1ø, 60 hz N/A 1.8
AMP DRAW OF ELECTRIC HEAT
Voltage
7.5 kw 10 kw 15 kw
208v 1ø - 60 hz 36.1 48.0 72.0
240v 1ø - 60 hz 31.4 41.7 62.5
208v 3ø - 60 hz 20.9 27.8 41.6
240v 3ø - 60 hz 18.1 24.1 36.1
480v 3ø - 60 hz 9.0 12.0 18.0
Note: When amp draw of motors and heaters are in excess of 48 amps, two power supplies are required.
*
3 Speed Rating @ Low / Medium /High
Dimensions on
Reverse Side
CP Form IBD-AD CP © 2006
5350 Campbells Run Road • Pittsburgh, PA 15205-9738
800-833-5005 • Tel: 412-787-9750 Fax: 412-787-3665
IBD AIR DOORS
AIR DOOR MODEL
IBD SERIES
For BACK DOORS and UTILITY ENTRANCES
Standard Amps for Amps for
Motor Voltages1/2 Motor3/4 Motor
120, 1ø, 60 hz 7.2 7.5
208, 1ø, 60 hz 4.0 3.8
240, 1ø, 60 hz 4.0 3.8
460, 1ø, 60 hz N/A 1.8
Insect Control Back Door: IBD-TQ SERIES – 1 Speed
MODEL IBD-TQ-2-36-1 IBD-TQ-2-42-1 IBD-TQ-2-48-1 IBD-TQ-2-60-1 IBD-TQ-3-60-2
Nozzle Width (in.) 36 42 48 60 60
Max. Velocity (fpm) 3850 3850 3850 3850 3850 Air Volume (scfm) 2200 2120 2270 2200 3300
No. of Motor(s) @ H.P. 1@
3
4
1@3⁄
4
1@3⁄
4
1@3⁄
4
2@3⁄
4
Power Rating (kw) .68 .75 .73 .74 1.18 Outlet Vel. Uniformity (%) 90 87 65 45 80 Sound Level 62 dBA 62 dBA 62 dBA 62 dBA 62 dBA Shipping Wt. Unheated (lbs.) 70 80 82 96 105 Electric Heater: Cap. (MB/hr) 25.598 25.598 34.130 34.130 51.195
Capacity (kw) 7.5 7.5 10 10 15 Temp. Rise (°F) 11 11 14 14 14
Ship. Wt. Heated Mod. (lbs.)
75 85 87 102 115
DIMENSIONS CFD and IBD SERIES
C
5.5''
.75''
2.75''
2''
A
B
15''
12.5''
“A” Overall Length 39'' 45'' 51'' 63''
“B” Nozzle Length 36'' 42'' 48'' 60''
“C” Outside
37.5'' 43.5'' 49.5'' 61.5''
Mounting Holes
AMP DRAW OF ELECTRIC HEAT
Voltage
7.5 kw 10 kw 15 kw
208v 1ø - 60 hz 36.1 48.0 72.0
240v 1ø - 60 hz 31.4 41.7 62.5
208v 3ø - 60 hz 20.9 27.8 41.6
240v 3ø - 60 hz 18.1 24.1 36.1
480v 3ø - 60 hz 9.0 12.0 18.0
Note: When amp draw of motors and heaters are in excess of 48 amps, two power supplies are required.
Loading...