Curtron CFD-TQ-2-36-1, CFD-TQ-2-42-1, CFD-TQ-2-48-1, CFD-TQ-2-60-1, CFD-TQ-3-60-1 Installation Manual

...
800•833•5005
Curtron Products • 5350 Campbells Run Road • Pittsburgh, PA 15205-9738 • 412.787.9750
• Fax: 412.787.3665 • Web Site: www.curtronproducts.com • E-Mail: info@curtronproducts.com
OTHER
CURTRON
PRODUCTS
POLAR-PRO
SWINGING DOORS
COOLER CURTAINS
CURTRONIZER
STRIP DOORS
TEMP KEEPERS
COOL KEEPERS
STRIP DOORS
Make Food Products
Your Number One Priority!
RACK COVERS
MODEL ENCLOSED:
CFD-TQ-2-36-1CFD-TQ-2-42-1CFD-TQ-2-48-1CFD-TQ-2-60-1CFD-TQ-3-60-1
IBD-TQ-2-36-1IBD-TQ-2-42-1IBD-TQ-2-48-1IBD-TQ-2-60-1IBD-TQ-3-60-2
CFD-HH-2-36-1-3SCFD-HH-2-42-1-3SCFD-HH-2-48-1-3SCFD-HH-2-60-1-3SCFD-HH-3-60-1-3S
INSTALLATION INSTRUCTIONS
AIR DOORS
Make Food Products
Your Number One Priority!
Copyright © 2007 Curtron Products Catalog No. CFD/IBDAD 06-07
2
3
Thank you for choosing a Curtron quality product.
UNCRATING
Carefully examine the carton(s) for damage before opening. If the carton is damaged, immediately notify the shipping company.
• Remove all protective packaging.
• Remove the cover housing by lifting vertically.
Enclosed is a packet of self-tapping screws which will be used to attach the cover housing to the mounted chassis.
CAUTION: LIFT THE UNIT BY GRASPING THE INLET RINGS ON THE
BLOWER HOUSING WITHOUT TOUCHING THE BLOWER WHEELS.
Excess weight on the blower wheels may cause improper alignment and bal­ance of the motor shaft and blower wheels.
WARNING:TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If you
have any questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at the service panel
and lock service panel to prevent power from being switched on acci­dentally.
C. Installation work and electrical wiring must be done by a qualified person
in accordance with all applicable codes and standards, including fire­rated construction.
D. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
E. Do not operate this fan with any solid state speed control device.
INDOOR AND OUTDOOR MOUNTING FOR CURTRON AIR DOORS
INDOOR MOUNTING - Environmental/Insect/ Dust Control
OUTDOOR MOUNTING - Insect/ Dust Control
NOTE: The air door is weatherproof; therefore, no special covering is required
for outdoor mounting.
IMPORTANT: A minimum of 4” is required above the top of the air door for the installation and removal of the cover housing.
1. Install the air door so that nothing interferes with the air stream when it is deflected 20° to either side. If the air stream strikes any obstruction, for example, the top edge of the doorway, a structural beam or a door opening device, its efficiency will be reduced. See Figure 1. On electrically heated units there should be a minimum clearance of at least 4” between the side of the unit and any combustible material, if the unit is enclosed in the ceiling or a decorative cover.
2. The outlet nozzle should be no more than 1” above the top of the doorway opening. See Figure 2A. If the air door must be mounted higher, then it should be spaced out from the wall 3/8” for every inch the unit is moved up above the doorway open­ing. Any void between the air door and the wall must be sealed (use foam, plastics or similar packing) for best performance. See Figure 2B.
Figure 1
Figure 2B
Figure 2A
FLUSH MOUNT
AIR
DOOR
1”
TOP OF DOORWAY
3”
2”
SPACER
SEAL
SPACER
3/8”
3/4”
4” MINIMUM SPACE REQUIRED
AIR INTAKE
AIR
DOOR
AIR
FLOW
MAX.
20°
MAX.
20°
OUTLET NOZZLE