Curtis enGage II 3000 Series, 3003R-57X-0001 Instructions Manual

1
enGage II: Programmable Battery Discharge
AMP
AutoRange Switch (-):
Technical Specifications
Indicator
3003R-57X-0001
Operating Voltage Range 12V-48VDC nominal voltage, +/-
25% Operating Current Range Nominal- 14 mA, maximum 20 mA. Values reflect key switch in "on" position Display: LCD with 10-segment bar and 5 digit numeric (5mm high)
Hour Meter Range: 99,999 Total Hours Hardware: Mounting Bracket Panel Cutout: 52 mm / 2 1/16" diameter Shock SAE J 1378 Amplitude
44-55 g, half sine, 9-13 ms duration Vibration SAE J 1378 Double amplitude of 1.53mm with frequency sweep for 10-80-10 Hz (20 g max) at 1 minute intervals
Storage Temperature: -50°C to +90°C Operating Temperature: -40°C to +85°C Humidity: 95% RH (non-condensing) IP Rating: 65 Front & Rear with AMP connector installed
(V+) Supply voltage positive
terminal
(V-) Supply voltage negative
terminal
Key switch (+): When V+ is
applied this switch operates the
gauge display
MOSFET output: MOSFET
(0.5A) open drain type internally
tied to V-.
Setup Enable (+): When V+
applied, gauge can be
programmed via panel buttons.
Hour Meter Enable (+): When
V+ applied, accumulation of
time occurs when key switch on.
.
Pin #
4
8
6
7
2
3
No connection = 24 04 48 VDC; Connection = 12 or 36 VDC
1
2
Entering the Configuration Mode
Configuration Notes
To change the Battery Discharge Profile V+ must be connected to the set up pin (2). After V+ is applied to pin 2 press and hold the left button until the time of day clock flashes the 4 clock digits. If no change in clock setting is desired use the left button to progress to the discharge profile
Configuring Your Gauge
Access to these operations is sequential in this order. Adjustments of the following functions can be performed in the Configuration Mode:
1. Time-of-Day Clock
2. Battery Discharge Indicator Profiles
During configuration, the right button is used to increment. The left button is used to:
1. Enter a selection
2. Advance to the next configurable item
If no change is desired to a specific gauge function, continue to press the left button until the next desired function is reached. The time-of-day clock is entered by setting the hours digits between 01 and 12, then "minutes" digits between "00" and "59".
The profile of the BDI is settable with the front panel buttons.
Setting the Battery Indicator Profiles
The display flashes the 3 digits of the discharge full profile. Press the right button to increment by 0.10 VPC or hold the button to increment continuously. When the display reaches 2.30 it will automatically restart at 1.80 VPC. When the desired reset profile setting is reached, press the left button once.
The display flashes the 3 digits of the discharge empty profile. Press the right button to increment by 0.10 VPC or hold the button to increment continuously. When the display reaches 2.20 it will automatically restart at 1.50 VPC. When the desired reset profile setting is reached, press the left button once.
Setting the Time-of-Day Clock
The display will flash the two "Hours" digits. Press the right button to increment by one hour, or hold the button to increment continuously. When the desired number of hours is reached, press the left button once. The display will flash the two "Minutes" digits. Press the right button to increment by one minute or hold the button to increment continuously. When the d esired number of minutes is reached, press the left button once.
The gauge remains in configuration mode for 30 seconds without input from the user. When configuring each function (time-of-day, BDI Profile), you must enter in all data for that function for it to be saved. If incomplete data is entered for a function and the programming mode is timed out (after 30 seconds of no input received by the gauge), the gauge will revert back to what was previously stored for that item.
1 0
Exiting Configuration Mode
The configuration mode can be exited in three ways:
1. Press and hold the left button for three seconds.
2. Leave buttons untouched for 30 seconds.
3. Press the left button after selecting the last (ri ght)
digit of the last function available.
Operation
When the main power (9-60 VDC) is applied to V+ and V-, a power-up sequence is initiated. All display segments are illuminated for one second. The display is then turned off until the key switch is activated.
Toggling Display Functions
Press the left button to sequentially toggle between the three numeric gauge functions (time-of-day clock, maintenance hours, total hours).
Setting/Changing the Time-of-
Day Clock
This can be done without V+ applied to Setup Enable pin. Press and hold the left button on the front panel until the entire display flashes and then release.
Resetting the BDI
OCR- Open circuit reset The BDI will reset when the gage is disconnected from the discharged battery and reconnected to a fully charged battery.
CTR – Charge Tracking Reset Battery state-of-charge will be tracked by the Gauge during the charging period.