should read: between #1 & #3 = 220v and
between #2 & #4 = 220v.
Check the voltage at the toggle switch, it
7
should read: between #1 & #3 = 220v and
between #2 & #4 = 220v.
Check if there is 120v between pins #8 and
8
#16 on molex connector at UCM.
If all steps were taken and the unit still does
9
not turn on, replace the UCM.
Not heating:
LCD reads “Heating”
Yes:
Verify 220 volts between #2 & #4 on the
Manual Reset Thermostat. If no, reset or
replace the Manual Reset Thermostat.
Yes:
Verify 220 volts across the Toggle Switch.
If no, replace the toggle switch.
Yes:
Verify 220 volts across the Heating Element. If yes, replace the Heating Element.
If no, verify 120 volts between the Triac
gate, Neutral, and L1. If yes, replace the
Triac, if no, replace the UCM.
No:
Verify that the panel breaker is turned on
and the receptacle has 220 volts. If not,
consult an electrician.
Overheating/Steaming:
LCD reads “Heating”
Verify that the resistance on the Temperature
Sensor is less than 10k ohms with a hot tank
(200+ degrees) If no, verify correct mounting
and that the walls of the tank are free of mineral deposits. If yes, bypass the sensor using a
jumper with a 5k ohm resistor. If the LCD reads
“ready” and the unit stops heating, replace the
temperature sensor, if not, replace the UCM.
LCD reads “Ready to Brew”
Check the triac for continuity across A1 & A2,
if continuity is present, replace the triac, if no
continuity, replace UCM.
Ensure that the temperature is adjusted to compensate
i
for high elevation. The factory setting is 200°F. The temperature setting will need to be reduced Two degrees
for every one thousand feet of elevation.
Service & Sales
1-800-421-6150
www.wilburcurtis.com
Page 6
TROUBLESHOOTING INSTRUCTIONS
TANK FILLING ISSUES
Not lling:
Yes:
Does the LCD read “Water Level
Error”?
Yes:
Verify the ow rate to be a minimum of 1
gpm from outlet of the water lter. If not,
ensure that the inlet side of the water
lter is receiving a minimum of 1 gpm. If
yes, replace the water lter. If not, con-
sult a plumber.
No:
Remove the orange wire from the probe.
Does the tank start lling?
Yes:
Replace water level probe
No:
Replace the UCM
BREWING ISSUES
LCD does not read “Brewing”:
If the LCD reads “Ready to Brew” and there is no
response when Brew Button is pressed, replace
the UCM.
LCD reads “Brewing”:
No water ow from the spray head:
Does water ow from the hot water faucet? If
yes, verify 120 volts at the dump valve coil. If
voltage is present at the dump valve coil, replace
the dump valve. If 120 volts is not present at
the dump valve coil, conrm continuity of wiring
between molex connector and Dump Valve. If
okay, replace the UCM. (Verify the resistance on
the dump valve coil to be open in one direction,
and under 2k ohm in the other direction BEFORE
REPLACING THE UCM) If water does not ow
from the hot water faucet, replace the Water Level Probe.
Brewing Short Pots:
Verify that the Hot Water Tank is lling correctly.
(See Tank Filling issues)
Overlling:
Turn OFF toggle switch.
Does the tank continue to ll?
Yes: Replace water inlet valve
No: Ground the probe wire to the chassis.
Does the tank continue to ll?
Yes: Replace the UCM
No: Replace Water Level Probe
Before replacing any parts, verify the
i
following:
Verify that the Dump Valve outlet tting on the tank,
the tubing between the tank outlet and the Spray head
tting, the Spray head, and Dump Valve are clear of
obstructions.
Ensure correct alignment of the spray head tting and
that the tubing is routed properly to allow for maximum
water ow. (No Kinks)
Overowing the Pot:
• Ensure that the Spray head has not been removed. Replace as needed.
• Ensure that the Hot Water Tank is not over-
owing (See Tank Filling Issues)
• Ensure that hot water is not owing from the
Dump Valve when the toggle switch is turned
off. If it is, replace the dump valve.