Curtis D500GT12A1000 TROUBLESHOOTING GUIDE

Page 1
CURTIS AIRPOT BREWER
TROUBLESHOOTING GUIDE
Service & Sales 1-800-421-6150
D500GT12A1000
G3 Single Airpot Coffee Brewer
(Dispenser Sold Separately)
www.wilburcurtis.com
Page 2
Page 3
BREWER PARTS IDENTIFICATION
WATER RELATED
1. WC-826L VALVE, INLET 1.0 GPM 120V
2. WC-5527K KIT, PROBE WATER LVL FITTING, ORING, NUT
3. WC-889-101 VALVE, DUMP LEFT 120V 12W
4. WC-3763 KIT, VALVE REPAIR (FOR WC-889, DUMP VALVE)
5. WC-29025 SPRAYHEAD, PURPLE ADVANCE FLOW
6. WC-37252 KIT, HOT WATER FAUCET REPLACEMENT
7. WC-1806 SEAT CUP, SILICONE
8. WC-3621-101 BREW BASKET, NON METAL
9. WC-3316 BREW BASKET, STAINLESS STEEL
Service & Sales
Service & Sales
1-800-421-6150
1-800-421-6150
DESCRIPTION
HEAT RELATED
10. WC-1438-101 SENSOR, TEMPERATURE TANK
11. WC-8556 HEAT SINK & TRIAC
12. WC-904-04 HEATING ELEMENT
13. WC-522 THERMOSTAT, HI LIMIT HEATER
DESCRIPTION
MASTER CONTROL
14. WC-37064
15. WC-102 SWITCH, TOGGLE DPST 25A 125/25OVAC
KIT, LABEL & UNIVERSAL CONTROL MODULE
www.wilburcurtis.com
www.wilburcurtis.com
Page 4
PARTS IMAGES
1
WC-826L
VALVE, INLET 1.0 GPM 120V
5
WC-29025
SPRAYHEAD, PURPLE
ADVANCE FLOW
2 3 4
WC-5527K
KIT, PROBE WATER LVL
FITTING, ORING, NUT
WC-889-101
VALVE, DUMP LEFT 120V 12W
6 7 8
WC-37252
KIT, HOT WATER FAUCET
REPLACEMENT
WC-1806
SEAT CUP, SILICONE
WC-3763
KIT, VALVE REPAIR
(FOR WC-889, DUMP VALVE)
WC-3621-101
BREW BASKET, NON METAL
9
WC-3316
BREW BASKET, STAINLESS STEEL
13
WC-522
THERMOSTAT, HI LIMIT HEATER
10 11 12
WC-1438-101
SENSOR, TEMPERATURE TANK
WC-8556
TRIAC & HEAT SINK
14 15
WC-37064
KIT, LABEL & UNIVERSAL
CONTROL MODULE
WC-102
SWITCH, TOGGLE DPST
25A 125/25OVAC
WC-904-04
HEATING ELEMENT
Service & Sales 1-800-421-6150
www.wilburcurtis.com
Page 5
TROUBLESHOOTING INSTRUCTIONS
POWER ISSUES
The unit will not turn on:
Check if the panel breaker is turned on. If it
1
is, proceed to STEP 2.
Check the voltage at the receptacle if it
2
reads: L1-L2 = 220v, L1-N = 120v, L2-N = 120v, N-G = 0v. Proceed to STEP 3 if accurate.
Check if the power cord is properly con-
3
nected to the receptacle. If it is, proceed to STEP 4.
Check that the toggle switch is in the ON
4
position. If it is ON, proceed to STEP 5.
HEATING ISSUES
Check the voltage at the power block, it
5
should read: L1-L2 = 220v, L1-N = 120v, L2-N = 120v, N-G = 0v.
Check the voltage at the reset thermostat, it
6
should read: between #1 & #3 = 220v and between #2 & #4 = 220v.
Check the voltage at the toggle switch, it
7
should read: between #1 & #3 = 220v and between #2 & #4 = 220v.
Check if there is 120v between pins #8 and
8
#16 on molex connector at UCM.
If all steps were taken and the unit still does
9
not turn on, replace the UCM.
Not heating:
LCD reads “Heating”
Yes:
Verify 220 volts between #2 & #4 on the Manual Reset Thermostat. If no, reset or replace the Manual Reset Thermostat.
Yes:
Verify 220 volts across the Toggle Switch. If no, replace the toggle switch.
Yes:
Verify 220 volts across the Heating Ele­ment. If yes, replace the Heating Element. If no, verify 120 volts between the Triac gate, Neutral, and L1. If yes, replace the Triac, if no, replace the UCM.
No:
Verify that the panel breaker is turned on and the receptacle has 220 volts. If not, consult an electrician.
Overheating/Steaming:
LCD reads “Heating”
Verify that the resistance on the Temperature Sensor is less than 10k ohms with a hot tank (200+ degrees) If no, verify correct mounting and that the walls of the tank are free of miner­al deposits. If yes, bypass the sensor using a jumper with a 5k ohm resistor. If the LCD reads “ready” and the unit stops heating, replace the temperature sensor, if not, replace the UCM.
LCD reads “Ready to Brew”
Check the triac for continuity across A1 & A2, if continuity is present, replace the triac, if no continuity, replace UCM.
Ensure that the temperature is adjusted to compensate
i
for high elevation. The factory setting is 200°F. The tem­perature setting will need to be reduced Two degrees for every one thousand feet of elevation.
Service & Sales 1-800-421-6150
www.wilburcurtis.com
Page 6
TROUBLESHOOTING INSTRUCTIONS
TANK FILLING ISSUES
Not lling:
Yes:
Does the LCD read “Water Level Error”?
Yes:
Verify the ow rate to be a minimum of 1 gpm from outlet of the water lter. If not,
ensure that the inlet side of the water
lter is receiving a minimum of 1 gpm. If yes, replace the water lter. If not, con-
sult a plumber.
No:
Remove the orange wire from the probe.
Does the tank start lling?
Yes:
Replace water level probe
No:
Replace the UCM
BREWING ISSUES
LCD does not read “Brewing”:
If the LCD reads “Ready to Brew” and there is no response when Brew Button is pressed, replace the UCM.
LCD reads “Brewing”:
No water ow from the spray head: Does water ow from the hot water faucet? If
yes, verify 120 volts at the dump valve coil. If voltage is present at the dump valve coil, replace the dump valve. If 120 volts is not present at
the dump valve coil, conrm continuity of wiring
between molex connector and Dump Valve. If okay, replace the UCM. (Verify the resistance on the dump valve coil to be open in one direction, and under 2k ohm in the other direction BEFORE
REPLACING THE UCM) If water does not ow
from the hot water faucet, replace the Water Lev­el Probe.
Brewing Short Pots:
Verify that the Hot Water Tank is lling correctly.
(See Tank Filling issues)
Overlling:
Turn OFF toggle switch.
Does the tank continue to ll?
Yes: Replace water inlet valve No: Ground the probe wire to the chassis.
Does the tank continue to ll?
Yes: Replace the UCM No: Replace Water Level Probe
Before replacing any parts, verify the
i
following:
Verify that the Dump Valve outlet tting on the tank,
the tubing between the tank outlet and the Spray head
tting, the Spray head, and Dump Valve are clear of
obstructions.
Ensure correct alignment of the spray head tting and
that the tubing is routed properly to allow for maximum
water ow. (No Kinks)
Overowing the Pot:
Ensure that the Spray head has not been re­moved. Replace as needed.
Ensure that the Hot Water Tank is not over-
owing (See Tank Filling Issues)
Ensure that hot water is not owing from the Dump Valve when the toggle switch is turned off. If it is, replace the dump valve.
Ensure Cold Brew Lock is set to 5°F.
Service & Sales 1-800-421-6150
www.wilburcurtis.com
www.wilburcurtis.com
Page 7
NOTES
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
Service & Sales 1-800-421-6150
www.wilburcurtis.com
Page 8
Wilbur Curs Co., Inc.
6913 Acco Street, Montebello CA 90640
Customer Service: 800.421.6150 | 323.837.2300
csrassistance@wilburcurs.com
Tech Support: 800.995.0417
www.wilburcurs.com
JAN/2016 M202_TS_WC_D500_revNC
Loading...