Curtis 700 series, 732 Series Instructions For Use Manual

Page 1
Read Instructions Carefully !
700/732 SERIES
®
CURTIS INSTRUMENTS, INC.
200 Kisco Avenue, Mt. Kisco, NY 10549 Tel. (914) 666-2971 • FAX (914) 666-2188
www.curtisinst.com
53004 REV F 06/02
5mm HOUR METERS & COUNTERS
Page 2
TABLE OF CONTENTS Page
1. Model Encodement 2
2. Technical Specifications
2.1 Electrical 6
2.2 Mechanical 11
2.3 Environmental 14
3. Installation 15
4. Operation 16
5. Troubleshooting 19
6. Maintenance 19
Safety Instructions
This instrument was manufactured and tested according to the applicable technical standards. It complies with all the safety regulations as shipped from the factory.
Installation and startup must be performed by skilled personnel. Failure to install and operate the unit in accordance with these
instructions may result in damage or injury. If safe operation of the instrument can no longer be ensured,
stop and secure it against accidental operation. If instrument failure or malfunction may cause personal injury or
material damage, use additional safety measures such as limit switches, guards, etc.
Read the Operating Instructions carefully before startup.
Note the safety instructions marked with this warning symbol in this manual.
!
Page 3
32
1 A. MODEL ENCODEMENT (except 732)
7uuvw001zxxyy 7 uu v w 001 z
Function Case Reset Sequential Logo
Code
!
xxyy
Nominal Voltage
(See Section 2.1 for absolute voltage ranges)
0512D = 5 to 12VDC 1248D = 12 to 48VDC 48150D = 48 to 150VDC 0512D0612A = 5 to 12VDC, 6 to 12VAC 1248D2060A = 12 to 48VDC, 20 to 60VAC 48150D100230A = 48 to 150VDC,100 to 230VAC
00 = 2 wire Hour Meter 01 = 3 wire Hour Meter 03 = Pulse Counter
See Section 2.2 for specifications
R = Electrical reset N = No reset
O = Curtis N = No Logo
Page 4
54
w xx y
LED Sequential Voltage (VDC) Code Logo
0 = 12 factory N= No Logo 1 = 24 specified O= Curtis
2 = 36 3 = 48
!
1 B. MODEL ENCODEMENT (732 only)
732 u
Case
N = Hex-shaped bezel, with
1
/4” Faston
terminals K = Hex-shaped bezel,
with Packard connector
See Section 2.2 for Specifications
Note: 732 has a built-in LED in its face
v
Function
0= 2-wire Hour Meter, no enable
LED gnd-enabled, no reset
1= 2-wire Hour Meter, no enable
LED pwr-enabled, no reset
2= 2-wire Hour Meter, no enable
LED gnd-enabled, w/reset
3= 2-wire Hour Meter, no enable
LED pwr-enabled, w/reset
4= 3-wire Hour Meter, w/enable
LED gnd-enabled, no reset
5= 3-wire Hour Meter, w/enable
LED pwr-enabled, no reset
Page 5
6
2. TECHNICAL SPECIFICATIONS
2.1 Electrical
Operating Voltage 700 Series
The operating voltage ranges specified apply to voltages connected between terminal 1 and terminal 2 (700,701,703), terminal 3 and terminal 2 (701,703 only), and terminal 4 and terminal 2 (Reset option).
1. DC Only Models: Nominal (VDC) Absolute (VDC)
5 to 12 4.75 to 15 12 to 48 9.0 to 60 48 to 150 36 to 185
2. DC/AC Models: Nominal (VDC) Absolute (VDC)
Same As Above
Nominal (VAC) Absolute (VAC)
6 to 12 5.0 to 15
20 to 60 15 to 75
100 to 230 75 to 270
!
732 Only
a) Voltages connected between pins 1 and 2 and
between 4 and 2 (Enable option)
3a. 732 DC only, all voltage models:
Nominal (VDC) Absolute (VDC)
12 to 48 9.0 to 60 b) LED voltages betweeen pins 3 and 2 3b. 732 LED voltages: Absolute (VDC)
12 9 to 15 24 18 to 30 36 27 to 45 48 36 to 60
Frequency (AC models)
The AC operating frequency range is 48 to 440 Hz.
Maximum AC-Reset Frequency is 150 Hz.
Accuracy
Model 700, 701, 732 = ±0.1% Model 703 = ±1 count
!
7
Page 6
98
Operating Current (All models except 732)
The maximum operating current at terminal 1 is tabu­lated below for each nominal operating voltage limit.
DC Operating Maximum Maximum Only Voltage (VDC) Current Current Model V+ to V++ @ V+ @ V++
5 to 12 0.5 mA 10.0 mA 12 to 48 0.8 mA 5.0 mA 48 to 150 0.8 mA 2.5 mA
DC/AC Operating Maximum Maximum Model Voltage Current Current
V+ to V++ @ V+ @ V++
VDC -
same as
above
6 to 12 VAC 0.7 mA 6.0 mA
20 to 60 VAC 0.5 mA 2.5 mA
100 to 230VAC 0.9 mA 2.0 mA
!
Operating Current (continued)
Operating Current - 732 only Single Voltage, DC only
Operating Maximum
Voltage (VDC) Current w/LED (mA)
12 15.0 24 10.0 36 7.0 48 5.0
!
Page 7
10 11
Impedance
The minimum impedance at terminal 3 and at terminal 4 are tabulated below for each model.
Voltage Impedance (Min) Impedance (Min)
Encodement Terminal 3 Terminal 4
0512D 10 K 25 K 1248D 60 K 70 K
48150D 480 K 480 K 0512D 0612A 10 K 25 K 1248D 2060A 70 K 70 K
48150D 100230A 480 K 480 K 732 (all voltages) 70 K
2.2 Mechanical
Display 6-digit LCD, 5 mm high Range & Resolution
700, 701, 732 Hour Meters 703 Counter
99,999.9 Hours 999,999 Counts
!
!
Page 8
Case & Connector Specifications
Note: K & N - LED indicator molded in bezel face (available as 732 models only)
G & H - Require 2-pin Delphi- Packard mating connector P/N 12162000
J, K & Y - Require 4-pin Delphi- Packard mating connector P/N 12162035
L - Snap tabs built in(no mounting hardware required); case and bezel 1-piece clear
Hexagonal - Screw mount through flange (optionally mounted with plastic bracket, available separately)
12
!
13
Case Bezel Shape Terminals Max Pins Mounting Lens Matrl. Case Matrl. Bezel Matrl. Panel Cutout (mm) Panel Cutout (in)
F Hexagonal1/4” Faston 4 Flange Acrylic ABS (black) ABS (black) 36.8x24.1 1.45x0.95
G Hexagonal Packard 2 Flange Acrylic ABS (black) ABS (black) 36.8x24.1 1.45x0.95
J Hexagonal Packard 4 Flange Acrylic ABS (black) ABS (black) 36.8x24.1 1.45x0.95 K Hexagonal Packard 4 Flange Acrylic ABS (black) ABS (black) 36.8x24.1 1.45x0.95 N Hexagonal1/4” Faston 4 Flange Acrylic ABS (black) ABS (black) 36.8x24.1 1.45x0.95 D Rect.-DIN3/16” Faston 4 U-bracket Acrylic ABS (black) ABS (black) 45x22.2 1.77x0.87 L Rectangular Molex-mini 4 Snap-in Polycarb. Polycarb. Polycarb. 36.8x24.1 1.45x0.95 H Rectangular Packard 2 Bracket (plast.) Acrylic ABS (black) Acrylic (clear) 36.8x24.1 1.45x0.95 Y Rectangular Packard 4 Bracket (plast.) Acrylic ABS (black) ABS (black) 36.8x24.1 1.77x0.87 Z Rectangular1/4” Faston 4 Bracket (plast.) Acrylic ABS (black) ABS (black) 36.8x24.1 1.77x0.87 Q Round
1
/4” Faston 4 U-bracket Glass Polycarb. Alum. Anodzd. (blk) 52 2 1/16
R (5mm) Round
3
/16” Faston 4 U-bracket Glass Polycarb. Alum. Anodzd. (blk) 52 2 1/16
Page 9
14
2.3 Environmental
Temperature
Operating: -40°C to +85°C Storage: -50°C to +90°C
Humidity 95% RH (Non Condensing) at 38°C Shock &
Vibration Meets SAE J 1378 Case - IP Ratings
!
15
3. INSTALLATION
V+ Operating voltage V– Common (ground) I Enable (optional, use operating voltage to power this pin
to record elapsed time (701) or increment count (703))
R Reset (optional, supply with operating voltage when unit
is to be reset to 0)
LED – Externally driven by active high or low – factory
configured
NC No connection
!
Case Style Pin 1 Pin 2 Pin 3 Pin 4
D, F, Q, R , J, Y, Z V+ V– I R
G, H V+ V– NC NC
L V+ V– I NC
K, N V+ V– LED I
Case Style D, Q, R F, Z, N G, J,Y, H, K L
Front 65 65 65 65
Rear 50 65 *65 40
*Note: Rated with mating connector installed
Page 10
16
applied for 5 seconds minimum, the accumulated time will be stored in non-volatile memory when power is removed. To Reset: (for Resettable Models) Apply DC+ or AC hot to pin 4 for 1/2 second minimum while power (pins 1 & 2) is applied for 5 seconds minimum. The reset voltage must be at the same level as the voltage used to power the unit.
703 Counter (AC/DC or DC Only)
To Display: Apply DC+ or AC hot to pin 1 and DC– or AC neutral to pin 2. The display is activated at this point but the count will not be started until a signal is applied to pin 3.
Note, for proper operation:
Power must be applied to pins 1 & 2 before or coincident with pin 3. To Operate: Apply DC+ or AC hot to pin 3. The count is incremented when the input signal is removed from pin 3. The input signal must be applied for 1/2 second minimum (AC/DC model) or for 1 millisecond mimimum (DC Only model). If power (pins 1 & 2) has been applied for 5 seconds minimum, the incremented count will be stored in non-volatile memory when power is removed. To Reset: (for Resettable Models) Apply DC+ or AC hot to pin 4 for 1/2 second minimum while power (pins 1 & 2) is applied for 5 seconds minimum. The reset voltage must be at the same level as the voltage used to power the unit.
4. OPERATION
NOTE: All models display an 8 in all digits for 1 sec. at power-up.
700 Hour Meter (AC/DC)
To Display & Operate: Apply DC+ or AC hot to pin 1 and DC– or AC neutral to pin 2. The accumulation of elapsed time is indicated by the flashing hourglass icon. If power has been applied for 5 seconds minimum, the accumulated time will be stored in non-volatile memory when power is removed. To Reset: (for Resettable Models) Apply DC+ or AC hot to pin 4 for 1/2 second minimum while power (pins 1 & 2) is applied for 5 seconds minimum. The reset voltage must be at the same level as the voltage used to power the unit.
701 Hour Meter (AC/DC or DC Only)
To Display:Apply DC+ or AC hot to pin 1 and DC– or AC neutral to pin 2. The display is activated at this point but the elapsed time will not be accumulated until a signal is applied to pin 3.
Note, for proper operation:
Power must be applied to pins 1 & 2 before or coincident with pin 3. To Operate: Apply DC+ or AC hot to pin 3 for 1/2 second minimum (AC/DC model) or DC+ for 1 millisecond mimimum (DC Only model). The accumulation of elapsed time is indicated by the flashing hourglass icon. If power (pins 1 & 2) has been
17
!
!
Page 11
19
5. TROUBLESHOOTING
To maximize the life of this meter, please read all instructions carefully and review Safety Precautions on inside front cover of this manual. Most minor prob­lems can be resolved by removing all power for at least 10 seconds and then reconnecting.
Problem Possible Causes
No Display Power not connected or too low. Display Present, but Input (or enable) wire not connected.
counter does not activate. Start Input not connected.
Input voltage not reaching specified minimum signal level.
LED not turning ON during Switch or switch-connection faulty. activation condition.
6. MAINTENANCE
Curtis Model 700 & 732 Series hour meters are not serviceable in the field. Units returned to the factory within the warranty period (see inside backcover) will be replaced without charge.
!
732 Hour Meter (DC Only)
To Activate Display: Apply DC+ to pin 1 and DC- to pin 2. To Activate LED: Apply DC+ (for active-high models) or DC-
(for active-low models) to pin 3 during indicator-on condition. To Activate Elapsed Time: For models without separate enable option - elapsed time is activated when power is applied to pins 1 & 2. For models with enable option - apply signal to pin 4. Note: Power (to pins 1 & 2) must be applied before or at the same time as signal to pin 4. Operation: Apply DC+ to pin 4 for 1 millisecond minimum. Activation (accumulation) of elapsed time is indicated by the hourglass icon flashing. Time accumulated will be stored into non-volatile memory when power is removed, if power (to pins 1 & 2) has been applied for the minimum of 5 seconds. Reset: (for resettable models), Apply DC+ to pin 4 for 1/2 sec- ond minimum, while power to pins 1 & 2 has been applied for 5 seconds minimum. Note: The reset voltage must be at the same level as the voltage used to power the unit.
18
Page 12
WARRANTY
Curtis Instruments’ products and/or components are guaranteed against defects in workmanship and material for a period of 2 years, or as defined in the individual product literature, from date of shipment from our factory, when applied in a proper application within specified ratings. This guarantee is limited to repair or replacement F.O.B. our factory. There is no further warranty or implied rep­resentation, guarantee, promise or agreement as to any Curtis Instruments product and/or component. Curtis Instruments, Inc., cannot assume responsibility or accept invoices for unau­thorized repairs to its products and/or components, even if defective. In no case will Curtis Instruments’ responsibility extend to products, components or equipment not of its manu­facture. Under no circumstances shall Curtis Instruments, Inc., be liable for any special or consequential damages or loss of profits or other damages. Returned goods will not be accepted unless identified by a Curtis Return Material Authorization (RMA).
All specifications are subject to change
without notice.
20
!