Installation Procedure
SAFETY
Always follow these safety precautions when
installing and operating the water filter system:
DO NOT use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.
DO NOT use a torch or other high temperature
sources near filter or cartridge.
DO NOT install on line pressures above 125 psi
(862 kPa).
DO NOT install on hot water line. Maximum
temperature allowed is 100°F (38°C).
DO NOT install in direct sunlight.
DO NOT reverse connections. The system must
be installed with the inlet and outlet as labeled.
DO NOT install filter system in locations where it
can be damaged by other freestanding equipment.
DRAIN filter system at temperatures below 40°F
(4.4°C). Protect from freezing.
INSTALLATION must comply with existing state
or local plumbing codes.
This piece of equipment is made in America and
has American sizes on hardware. All metric
conversions are approximate and vary in size.
FEEDWATER PARAMETERS
Be sure to confirm that the feedwater falls within
the limits shown below. If you’re not sure if this has
been done, check with your distributor before
installing the system. This is important because
failures caused by water related problems are not
covered under the system warranty.
Feed TDS . . . . . . . . .Up to 2,000 ppm (mg/L)
Hardness* . . . . . . . . . . .<10 grains (171 mg/L)
Iron (Fe) . . . . . . . . . . . . . . . . . . . . . .<0.1 mg/L
Hydrogen Sulfide . . . . . . . . . . .none allowable
Feed pH . . . . . . . . . . . . . . . . . . . . . . . . . .4-11
Free chlorine . . . . . . . . . . . . . . . . . . . .<2 mg/L
Manganese (Mn) . . . . . . . . . . . . . .<0.05 mg/L
Turbidity . . . . . . . . . . . . . . . . . . . . . . . .<5 NTU
* NOTE: For waters over 10 grain hard, a CUNO water
softener is recommended for pretreatment. Consult
CUNO technical services for correct sizing
.
PARTS LIST (SEE FIGURE 1, PAGE 2)
THE FOLLOWING PARTS ARE INCLUDED WITH
THE SCALEGARD REVERSE OSMOSIS WATER
FILTRATION SYSTEM. PLEASE UNPACK THE
CONTENTS FROM THE PRODUCT BOX AND
CHECK TO VERIFY THAT ALL OF THE PARTS
LISTED BELOW ARE INCLUDED. SHOULD ANY
PARTS BE MISSING, PLEASE CONTACT CUNO
AT 1-888-218-2866.
QTY DESCRIPTION
1 TANK & BRACKET ASSEMBLY
1 PREFILTER CARTRIDGE
1 REVERSE OSMOSIS MEMBRANE
CARTRIDGE
1 WATER SAMPLE VALVE ASSEMBLY
(SEE FIGURE 1)
1 1’ LENGTH OF 3/8” BLUE TUBING
1 10’ LENGTH OF RED TUBING
1 ADAPTER - STEM X BARB (1/4X1/4”)
1 ADAPTER - STEM X BARB (3/8 X 1/4”)
MOUNTING
1) Remove the mounting bracket template from
this manual. Tape it to the wall where the
mounting bracket is to be installed.
2) Install mounting screws (not included) into
each of the keyhole locations on the template.
Be sure to leave a 1/8" to 1/4" space between
the bottom of the screw head and the wall so
that the bracket can be hung.
NOTE: Mounting hardware must be
capable of supporting a minimum of 50 lbs
(22.7 kg).
3) Hang the Bracket/Tank Assembly from the
mounting screws.
4) Once the bracket is hung, tighten the
mounting screws so that the bracket is snug
between the screw and the wall.
Note: Make sure that the bracket is securely
mounted to a wall stud or other appropriate
wall structure.
1