The JetSort® model 1606 can be interfaced with a JetScan® Single-Pocket and Dual-Pocket
currency scanner or a JetCount® currency counter. The JetSort acts as the host to the JetScan or
JetCount and can display and print machine totals, depending on how these functions are
programmed through setup.
This document explains the interface between the JetSort and the JetScan and JetCount as well as
basic functions when these machines operate together. For complete information about JetSort,
JetScan or JetCount operations, see the following documents.
2 | JetSort® 1606 interface with JetScan or JetCount | Introduction
Key functions change when in Setup Mode. Note the following key functions while
navigating through the setup screens.
Key Names
Function Description
Start S/Bat
Scroll Forward:
With cursor on top line, scrolls forward through menu screens.
With cursor on bottom line, scrolls forward through selection options.
Start Batch
Scroll Backward:
With cursor on top line, scrolls backward through menu screens.
With cursor on bottom line, scrolls backward through selection options.
Print
Next Line -- moves cursor from top to bottom menu line and vice versa.
Totals
Option Forward Key – scrolls through menu options so user can make or
change a selection
Denom
Option Backward Key – scrolls through menu options so user can make or
change a selection
Clear
Exit Setup Mode.
Key Names
Function Description
Key 15
Press and hold (three to five seconds) for SETUP menu.
Key 5
Scroll Forward – Scrolls forward through menu screens.
Key 4
Scroll Backward – Scrolls backward through menu screens.
Key 3
Enter OPTIONS menu for specific option selections.
Key 13
Option Backward Key – scrolls through menu options so user can make or
change a selection
Key 14
Option Forward Key – scrolls through menu options so user can make or
change a selection
Key 6
Exit OPTIONS menu.
Key 7
Exit Setup Mode.
Setup
Setup Mode Function Keys
JetSort Function Keys
JetScan and JetCount Function Keys
Setup | JetSort® 1606 interface with JetScan or JetCount | 3
Install Software Kit 2 and Kit 4 before connecting the JetScan (model 4062 and higher)
or JetCount (model 4020 or higher).
JetScan and JetCount Bilcnt must be set to AUTO or DEMND.
Bilcnt
Prnt:
Auto
All
Connecting Your JetSort
Program JetSort to Operate with JetScan or JetCount
To set bill count and print features:
1. From the SETUP menu, advance to the BILCNT menu.
2. Press PRINT to move the cursor to the bottom menu line.
3. Press TOTALS or DENOM to scroll to the desired setting:
Auto – Note totals appear after each sub-batch is ended.
Dmnd – Note totals appear only when MEDIA is pressed.
4. Press START S/BAT to move the cursor to the Prnt option.
5. Press TOTALS or DENOM to scroll to the desired setting:
6. All – prints totals by denomination of processed currency.
7. Total – prints total of processed currency.
8. Press CLEAR to exit or continue to the next menu option by pressing PRINT, then START S/BAT.
9. Press PRINT to exit OPTIONS menu.
10. Press START S/BAT to scroll to the PORT 1 menu.
4 | JetSort® 1606 interface with JetScan or JetCount | Connecting Your JetSort
Peripheral Device
Device Options
Baud Rate Options
Stop Bits/Parity
Options
JetScan
JtS
600
1200
2400
4800
9600
7, NP
7, Evn
7, Odd
8, NP
8, Evn
8, Odd
JetCount
JtC
JetSort
JETSORT
PORT 1
SETUP:
JtC
2400, 7, NP
Set Peripheral Device, Baud Rate, Stop Bits and Parity
JetSort has four communication ports. In order to connect a JetScan or JetCount, baud rate, stop
bits and parity must be set. The exact settings for baud rate, stop bits and parity are irrelevant as
long as the JetSort settings match the JetScan or JetCount settings.
Set JetSort Communication Ports
1. Press PRINT to move the cursor to the bottom menu line.
2. Press TOTALS to scroll to peripheral type: JtS (JetScan) or JtC (JetCount). For more information about
other peripheral types, see the JetSort 1000 Series Coin Sorter Operating Instructions.
3. Press START S/BAT to advance to Baud Rate options.
4. Press TOTALS to scroll to correct Baud Rate (see table above).
5. Press START S/BAT to advance to Stop Bits and Parity options.
6. Press TOTALS to scroll to correct Stop Bits and Parity (see table above).
7. Press CLEAR to exit.
8. Connect cable to the programmed port.
Connecting Your JetSort | JetSort® 1606 interface with JetScan or JetCount | 5
Denomination
Sub Batch
Strap Count
7) PORT 1 STATUS
JETSORT 2400 7 NP
Mode
Batch
Strap Limit
Set JetScan or JetCount Communication Ports
To set port to match JetSort baud rate, stop bits and parity.
1. Press and hold key 15.
2. Press key 3 for the SETUP menu.
3. Press key 5 until PORT 1 STATUS menu is reached.
4. Press key 3 to bring the arrow prompt to the setting filed.
5. Press key 13 to select the desired peripheral: JetSort.
6. Press 5 to move the arrow to the next field.
7. Repeat steps 5 and 6 to set Baud Rate, Stop Bits and Parity (see table on previous page).
8. After setting the desired modes, press key 6 to exit OPTIONS menu then key 7 to exit SETUP menu.
9. Connect Cables.
6 | JetSort® 1606 interface with JetScan or JetCount | Connecting Your JetSort
TOT
10.00
COMPLETE
<ENTER>
R&C
$
23.48
Batch Waiting
R&C
$
23.48
Batch Ended
How to Use
Batch Processing
Start Batch with JetSort and JetScan
1. Pour coins from lift tray into coin hopper.
2. On the JetSort, press START BATCH.
3. On the JetScan, select a currency Operating Mode (Count, Sort or Mixed).
4. Place currency in the JetScan hopper.
5. JetScan will automatically begin processing currency and will stop to display prompts, depending on
which Operating Mode is chosen.
6. The JetSort displays <ENTER> and the amount of currency processed.
7. Press ENTER to accept the currency total and display the total amount of coins and currency
processed.
8. Press CONT to continue processing coins/currency or press END to finish.
Retrieve JetScan Information (Single Pocket)
JetSort displays running totals for all coins and currency while in the Batch Waiting condition. Press
individual denomination keys from the JetSort Batch Waiting screen to view values for each
denomination.
To display totals on the JetScan Single-Pocket, use the following steps:
1. Press DENOM on JetScan to display totals for individual denominations.
2. Press UNIT on JetScan to alternate between total bill counts, total dollar values, denomination counts
and values, and strap limit counts and values.
Retrieve JetScan Information (Two Pocket)
To display totals on the JetScan Two-Pocket, use the following steps:
1. Press MENU on JetScan touch screen.
2. Press BATCH to display totals.
How to Use | JetSort® 1606 interface with JetScan or JetCount | 7
PSS
100
Strap For:
$5
PSS limits are not saved in JetSort memory.
To manually enter currency through the JetSort, enable “Currency” in the
JetSort SETUP menu. For more information, see JetSort 1000 Series Coin
Sorter Operating Instructions.
Strap Limits – JetScan
When JetScan operates in Stranger, Sort and Count Modes, JetSort displays Strap Limit messages
when denomination counts exceed set limits for a denomination. Strap limits are programmed
through the JetScan SETUP menu. For more information, see the JetScan Single-Pocket Operating
Instructions or JetScan Two-Pocket Operating Instructions.
Strap Limits – JetCount
JetSort contains the function to enter values for Programmable Strap Stops (PSS). When activated,
the JetSort PSS function will override the JetCount strap settings.
To activate PSS settings on the JetSort:
1. Press LIMITS.
2. Press DENOM to select the desired denomination.
3. Using the numeric keypad, enter the strap-limit value.
4. Press ENTER to save the setting or CLEAR to re-enter the limit.
5. Press LIMITS twice to exit and return to a Batch Ended condition.
Manually Enter Currency/Data
1. Press START BATCH.
2. Enter the currency amount on the numeric keypad. Press ENTER. The currency amount is displayed on
the JetSort screen.
3. Press ENTER a second time to save totals and return to the Batch Waiting condition.
8 | JetSort® 1606 interface with JetScan or JetCount | How to Use
TOT
70.00
COMPLETE
<ENTER>
Correcting Manually Entered Currency/Data
If an incorrect value is entered on the keypad, but ENTER has not yet been selected, press CLEAR
and re-enter the correct value. If an incorrect value is entered and ENTER has been selected, an
adjustment amount must be entered.
To make an adjustment to a media balance, enter on the numeric keypad the amount which must
be adjusted (added or subtracted from the amount previously entered). To add the adjustment
amount to the media total, press Enter. To subtract the adjustment amount from the media total,
press “ - “.
Press Enter to record the media value and return to the Batch Waiting condition.
Add to JetScan Totals through JetSort
1. From the Batch Waiting condition, press MEDIA.
2. Press DENOM to select the desired denomination.
3. Enter the total units for the desired denomination on the numeric keypad. For example, seven $10
notes are entered as 7.
4. Press ENTER.
5. Press DENOM to cycle through the denomination screens until the following screen appears:
6. To add notes to any entry, repeat steps two through seven.
7. Press ENTER to save new totals and return to Batch Waiting condition.
How to Use | JetSort® 1606 interface with JetScan or JetCount | 9
TOT
13.48
COMPLETE
<ENTER>
Subtract from JetScan Totals through JetSort
1. From the Batch Waiting condition, press MEDIA.
2. Press DENOM to select the desired denomination.
3. Press CLEAR. JetSort will clear counts of the selected denomination.
4. Press DENOM to cycle through the denomination screens until the following screen appears:
5. Press ENTER to save new totals and return to Batch Waiting condition.
Printing Reports
JetSort Batch Reports will display individual or combined currency counts and values based on
PRINT FORMAT (1) and PRINT FORMAT (2) settings selected through JetSort setup. Additional
reports through the JetScan or JetCount interface vary depending on the options selected through
setup.
For more information, see machine operating instructions. Part numbers for operating instructions
are listed on page 3 under Introduction.
10 | JetSort® 1606 interface with JetScan or JetCount | How to Use
852 Feehanville Drive
Mt. Prospect, IL 60056
800 786 5528
All trademarks remain the property of their respective owners.
Information is subject to correction or change without prior notice.
This manual contains proprietary information of Cummins Allison. It is intended solely for the information and use of parties authorized by Cummins Allison to maintain the
equipment described herein. Such proprietary information may not be used, reproduced, or disclosed to any other pa rties for any other purpose without express written
permission of Cummins Allison.
022-7239-00 Rev. C
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.