CUMMINS MDKBH, MDKBN, MDKBK, MDKBM, MDKBL Operation, Maintenance And Parts Manual

...
Page 1
F-1576c 1 of 2
Quiet DieselE Series Operation, Maintenance and Parts
PRE-START CHECKS
Before the first start of the day and after every eight hours of operation:
1. Check for proper oil and coolant levels.
2. Check for fuel, coolant and water leaks, mechanical damage, loose parts, damaged exhaust hose, loose or corroded battery connections, clogged sea water strainer, and CO monitors that don’t work. Service as necessary.
3. Check for swimmers that might be exposed to the engine exhaust.
4. Turn off air conditioners and other large appliances.
PRIMING THE FUEL SYSTEM
If the generator ran out of fuel, push the control switch to STOP (Prime) and hold for at least 30 seconds.
STARTING THE GENERATOR
1. Push and hold the control switch at START (Pre­heat) until the generator starts. The amber status
lamp on the control switch will blink rapidly.* The amber lamp will go out and the green run lamp on the switch will light after the starter has discon­nected and the engine is up to speed. (Depending on how cold the engine is, preheat can take as long as 15 seconds before cranking starts.)
2. For longer engine life, let the engine warm up for two minutes before turning on air conditioners and other large appliances.
3. Check for water, coolant, fuel and exhaust leaks. Stop the generator immediately if there is a leak.
WARNING
!
Fuel and exhaust leaks can lead to severe personal injury or death. Shut down the generator immediately. Repair fuel leaks imme­diately. Do not run the generator until fuel and exhaust leaks have been repaired.
4. If the generator fails to start, cranking will discon­tinue in 20 to 60 seconds, depending on how cold the engine is, and the amber status lamp will blink Shutdown Code No. 4. See Troubleshooting (Oper- ator’s Manual) if the generator does not start after two or three tries.
CAUTION
!
Do not continue cranking and risk burning out the starter or flooding the engine (exhaust flow during cranking is too low to expel water from the exhaust system). Find out why the generator does not start and repair as nec­essary.
5. If the generator shuts down, the amber status lamp will blink a shutdown code. See SHUTDOWN CODES below.
STOPPING THE GENERATOR
Turn off air conditioners and other large appliances and let the generator run for two minutes to cool down. Then touch the Control Switch to STOP (Prime).
SHUTDOWN CODES
The amber status lamp will blink if the generator shuts down. It will blink 1, 2, 3, 4 or 7 times, pause, and then repeat the blinking. The number of blinks is the shut- down code. Blinking continues for five minutes and stops. To restore blinking press the control switch to STOP (Prime) until the amber lamp comes on (3 to 4 seconds). Then press STOP (Prime) three times to re­stores blinking.
One blink indicates shutdown due to high engine temperature.
Two blinks indicate shutdown due to low oil pres- sure.
Three blinks indicate shutdown that may require service. See Troubleshooting in the Operator’s Manual.
Four blinks indicate shutdown due to a failure to start within the time allowed for cranking.
Seven blinks indicate shutdown due to a loss of raw water flow for engine and exhaust cooling.
See Troubleshooting in the Operator’s Manual for more information.
CUMMINS ONAN DIGITAL DISPLAY
See the generator Operator’s Manual for details.
* The green run lamp and gauges will also flash momentarily.
Page 2
Printed in U. S. A. 04/07
F-1576c2 of 2
PERIODIC MAINTENANCE SCHEDULE
MDKBH
MDKBK, MDKBL, MDKBM, MDKBN,
MDKBP, MDKBR, MDKBS
MDKBT, MDKBU
MDDCA, MDDCB, MDDCC, MDDCD,
MDDCE, MDDCF, MDDCG, MDDCH,
MDDCJ
General Inspection
1
Every day, 8 Hrs Every day, 8 Hrs Every day, 8 Hrs Every day, 8 Hrs
Check Battery
2
Check VBelt Tension
3
Monthly 100 Hrs
Monthly 100 Hrs
Monthly 100 Hrs
Monthly 100 Hrs
Drain Water from Fuel Filters (Primary or Secondary)
Monthly, 100 Hrs Monthly, 100 Hrs Monthly, 100 Hrs Monthly, 100 Hrs
Check Siphon Break
Change Oil/Oil Filter First 50 Hrs Yearly, 200 Hrs First 50 Hrs Yearly, 200 Hrs First 50 Hrs Yearly, 350 Hrs First 50 Hrs Yearly, 350 Hrs
Check Brushes & Slip Rings
4
Yearly, 200 Hrs
Change Fuel Filter
Yearly 500 Hrs
Yearly, 350 Hrs
Replace Pump Impeller
Yearly, 500 Hrs
Yearly, 500 Hrs Yearly, 500 Hrs
Yearly 500 Hrs
Replace Zinc Anode
ea y, 500 s
ea y, 500 s
Yearly, 500 Hrs
Adjust Valve Lash
4
800 Hrs 800 Hrs 1000 Hrs
2 Yrs 2100 Hrs
Change Coolant, Pressure Cap & Thermostat 2 Yrs 2 Yrs 2 Yrs
2 Yrs, 2100 Hrs
Check Generator Bearing(s) & Drive Belt
4
5 Yrs, 2000 Hrs 5 Yrs, 2000 Hrs 5 Yrs, 2000 Hrs 5 Yrs, 2000 Hrs
Check Air Filter Yearly, 700 Hrs
1. Includes Oil Level, Coolant Level, Fuel System, Exhaust System, Battery, and Sea Water Strainer Checks
2. See battery manufacturer recommendations
3. Check for slippage, cracking and wear (pump drive belt only)
4. Must be performed by a trained and experienced mechanic (Cummins Onan Distributor or Dealer) in accordance with the engine and generator service manuals
MAINTENANCE PARTS
MDKBH
MDKBK, MDKBL, MDKBM,
MDKBN
MDKBP, MDKBR, MDKBS MDKBT, MDKBU
MDDCA, MDDCB, MDDCC,
MDDCF, MDDCG
MDDCD, MDDCE, MDDCH,
MDDCJ
Oil Filter 1857444 1855835 1220810 1220906 1220885 1220885
Fuel Filter 1492106 1492106 1492106 1492804 1492722 & 1492723 1492724 & 1492725
Crankcase Breather 1855523 1856721 1856721 1232327 1232259 1232259
Pump Impeller 1320415 1320379 1320349 5411316 1320436 1320436
12V Glow Plugs
1
1855421 1855421 1855990 3330745
24V Glow Plugs
1
185-7268 1856725 3330746
Zinc Pencil 130−4434 130−4434 130−4434 130−6228 130−6228
VBelt 5110197 1856934 Note 2 5110237 5110215 5110215
Oil Filter Wrench 4200577
Air Filter 140−3752 140−3752
Cruise Kit 100347858 100347852 Note 3 100347860
1. Number of glow plugs: 2−MDKBH; 3−MDKBL & MDKBK; 4−MDKBM, MDKBN, MDKBP, MDKBR, MDKBT & MDKBU; 5−MDKBS
2. MDKBP and MDKBR with negative ground (Option # B200 or B201): 5110201, MDKBS with negative ground (Option # B200 or B201): 1857055, MDKBP, MDKBR and MDKBS with isolated ground systems (Option # B379 or B380): 511−0211
3. MDKBP and MDKBR with negative ground (Option # B200 or B201): 100347854, MDKBS with negative ground (Option # B200 or B201): 100347856, MDKBP, MDKBR and MDKBS with isolated ground systems (Option # B379 or B380): 100347855
ENGINE FLUID CAPACITIES
MDKBH MDKBK, MDKBL MDKBM, MDKBN MDKBP, MDKBR MDKBS MDKBT, MDKBU
MDDCA, MDDCB,
MDDCC, MDDCF,
MDDCG
MDDCD, MDDCE,
MDDCH, MDDCJ
Oil 2.1L (2.2Qt) 4.0L (4.2Qt) 4.3L (4.5Qt) 7.6L (8Qt) 12L (12.7Qt) 10.4L (11Qt) 12.6L (13.3Qt) 19.4L (20.5Qt)
Coolant 2.1L (2.2Qt) 4.0L (4.2Qt) 5.0L (5.3Qt) 7.6L (8Qt) 7.6L (8Qt) 13.7L (14.5Qt) 14L (15Qt) 30L (32Qt)
Shipped with 15W40 engine oil and 50/50 water/ethylene glycol coolant
Contact your Cummins Onan Distributor or Dealer for more information. Cummins Power Generation, 1400 73rd Ave. NE, Minneapolis, MN 55432, USA, Phone 1-763-574-5000, Toll-free 1-800-888-6626,
Fax 1-763-574-5298, Email www.cumminsonan.com/contact, www.cumminsonan.com.
Cummins®, Onan®, the “C” logo, “Performance you rely on” and Quiet Diesel are trademarks or registered trademarks of Cummins Inc. ©2007 Cummins Power Generation. All Rights Reserved.
Loading...